메뉴 건너뛰기




Volumn 25, Issue 3, 2004, Pages 271-274

Interobserver agreement of coiling of Med-El cochlear implant: Plain x-ray studies

Author keywords

Cochlear implant; Electrode; Observer variation; X ray

Indexed keywords

ANALYTIC METHOD; ARTICLE; COCHLEA PROSTHESIS; ELECTRODE; HUMAN; IMAGE ANALYSIS; MEASUREMENT; MEDICAL SPECIALIST; OBSERVER VARIATION; OTORHINOLARYNGOLOGY; PRIORITY JOURNAL; RADIOGRAPHY; REPRODUCIBILITY; TREATMENT OUTCOME;

EID: 4043056685     PISSN: 15317129     EISSN: None     Source Type: Journal    
DOI: 10.1097/00129492-200405000-00012     Document Type: Article
Times cited : (17)

References (10)
  • 1
    • 4043062118 scopus 로고    scopus 로고
    • Sylmar, CA: Advanced Bionics Corp
    • Surgical Support Information Guide. Sylmar, CA: Advanced Bionics Corp; 2001:30.
    • (2001) Surgical Support Information Guide , pp. 30
  • 4
    • 0027236682 scopus 로고
    • Radiologic evaluation of multichannel intracochlear implant insertion depth
    • Marsh MA, Xu J, Blamey PJ, et al. Radiologic evaluation of multichannel intracochlear implant insertion depth. Am J Otol 1993;14:386-91.
    • (1993) Am J Otol , vol.14 , pp. 386-391
    • Marsh, M.A.1    Xu, J.2    Blamey, P.J.3
  • 5
  • 6
    • 0033985953 scopus 로고    scopus 로고
    • Cochlear view: Postoperative radiography for cochlear implantation
    • Xu J, Xu SA, Cohen LT, et al. Cochlear view: postoperative radiography for cochlear implantation. Am J Otol 2000;21:49-56.
    • (2000) Am J Otol , vol.21 , pp. 49-56
    • Xu, J.1    Xu, S.A.2    Cohen, L.T.3
  • 7
    • 0034595867 scopus 로고    scopus 로고
    • Postoperative imaging and evaluation of the electrode position and depth of insertion of multichannel cochlear implants by means of high-resolution computed tomography and conventional x-rays
    • Czerny C, Gstoettner W, Adunka O, et al. Postoperative imaging and evaluation of the electrode position and depth of insertion of multichannel cochlear implants by means of high-resolution computed tomography and conventional x-rays [in German]. Wien Klin Wochenschr 2000;112:509-11.
    • (2000) Wien Klin Wochenschr , vol.112 , pp. 509-511
    • Czerny, C.1    Gstoettner, W.2    Adunka, O.3
  • 9
    • 0026625643 scopus 로고
    • High-resolution CT of the temporal bone: A modified baseline
    • Torizuka T, Hayakawa K, Satoh Y, et al. High-resolution CT of the temporal bone: a modified baseline. Radiology 1992;184:109-11.
    • (1992) Radiology , vol.184 , pp. 109-111
    • Torizuka, T.1    Hayakawa, K.2    Satoh, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.