메뉴 건너뛰기




Volumn 28, Issue 4, 2007, Pages 645-650

Reduction of radiation dose for cerebral angiography using flat panel detector of direct conversion type: A vascular phantom study

Author keywords

[No Author keywords available]

Indexed keywords

ANEURYSM; ARTICLE; BRAIN ANGIOGRAPHY; DIGITAL SUBTRACTION ANGIOGRAPHY; FLAT PANEL DETECTOR; IMAGE INTENSIFIER; IMAGE QUALITY; NEUROIMAGING; PHANTOM; RADIATION DOSE; TELEVISION;

EID: 34247269288     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (12)

References (25)
  • 1
    • 0030050484 scopus 로고    scopus 로고
    • Techniques for reducing interventional neuroradiology skin dose: Tube position rotation and supplemental beam filtration
    • AM Norbash, D Busick, MP Marks. Techniques for reducing interventional neuroradiology skin dose: tube position rotation and supplemental beam filtration. AJNR Am J Neuroradiol 1996;17:41-49
    • (1996) AJNR Am J Neuroradiol , vol.17 , pp. 41-49
    • Norbash, A.M.1    Busick, D.2    Marks, M.P.3
  • 2
    • 0027960590 scopus 로고
    • Radiation-induced temporary epilation after a neuroradiologically guided embolization procedure
    • Huda W, Peters KR. Radiation-induced temporary epilation after a neuroradiologically guided embolization procedure. Radiology 1994;193:642-44
    • (1994) Radiology , vol.193 , pp. 642-644
    • Huda, W.1    Peters, K.R.2
  • 3
    • 0028061591 scopus 로고
    • Radiation exposure in endovascular surgery of the head and neck
    • Kuwayama N, Takaku A, Endo S, et al. Radiation exposure in endovascular surgery of the head and neck. AJNR Am J Neuroradiol 1994;15:1801-08
    • (1994) AJNR Am J Neuroradiol , vol.15 , pp. 1801-1808
    • Kuwayama, N.1    Takaku, A.2    Endo, S.3
  • 4
    • 84960950194 scopus 로고
    • A clinical study of radiation cataracts and the relationship to dose
    • Merriam GR Jr, Focht EF. A clinical study of radiation cataracts and the relationship to dose. Am J Roentgenol Radium Ther Nucl Med 1957;77:759-85
    • (1957) Am J Roentgenol Radium Ther Nucl Med , vol.77 , pp. 759-785
    • Merriam Jr, G.R.1    Focht, E.F.2
  • 6
    • 0342264667 scopus 로고    scopus 로고
    • Simulated bone erosions in a hand phantom: Detection with conventional screen-film technology versus cesium iodide-amorphous silicon flat-panel detector
    • Strotzer M, Volk M, Wild T, et al. Simulated bone erosions in a hand phantom: detection with conventional screen-film technology versus cesium iodide-amorphous silicon flat-panel detector. Radiology 2000;215:512-15
    • (2000) Radiology , vol.215 , pp. 512-515
    • Strotzer, M.1    Volk, M.2    Wild, T.3
  • 7
    • 0036153992 scopus 로고    scopus 로고
    • Performance of a flat-panel detector in detecting artificial bone lesions: Comparison with conventional screen-film and storage-phosphor radiography
    • Ludwig K, Lenzen H, Kamm KF, et al. Performance of a flat-panel detector in detecting artificial bone lesions: comparison with conventional screen-film and storage-phosphor radiography. Radiology 2002;222:453-59
    • (2002) Radiology , vol.222 , pp. 453-459
    • Ludwig, K.1    Lenzen, H.2    Kamm, K.F.3
  • 8
    • 0031859116 scopus 로고    scopus 로고
    • Clinical application of a flat-panel x-ray detector based on amorphous silicon technology: Image quality and potential for radiation dose reduction in skeletal radiography
    • Strotzer M, Gmeinwieser J, Volk M, et al. Clinical application of a flat-panel x-ray detector based on amorphous silicon technology: image quality and potential for radiation dose reduction in skeletal radiography. AJR Am J Roentgenol 1998;171:23-27
    • (1998) AJR Am J Roentgenol , vol.171 , pp. 23-27
    • Strotzer, M.1    Gmeinwieser, J.2    Volk, M.3
  • 9
    • 0033985984 scopus 로고    scopus 로고
    • Digital radiography versus conventional radiography in chest imaging: Diagnostic performance of a large-area silicon flat-panel detector in a clinical CT-controlled study
    • Garmer M, Hennigs SP, Jager HJ, et al. Digital radiography versus conventional radiography in chest imaging: diagnostic performance of a large-area silicon flat-panel detector in a clinical CT-controlled study. AJR Am J Roentgenol 2000;174:75-80
    • (2000) AJR Am J Roentgenol , vol.174 , pp. 75-80
    • Garmer, M.1    Hennigs, S.P.2    Jager, H.J.3
  • 10
    • 0028101786 scopus 로고
    • Artificial bone erosions: Detection with magnification radiography versus conventional high-resolution radiography
    • Link TM, Rummeny EJ, Lenzen H, et al. Artificial bone erosions: detection with magnification radiography versus conventional high-resolution radiography. Radiology 1994;192:861-64
    • (1994) Radiology , vol.192 , pp. 861-864
    • Link, T.M.1    Rummeny, E.J.2    Lenzen, H.3
  • 11
    • 0032525017 scopus 로고    scopus 로고
    • Maximum-likelihood estimation of receiver operating (ROC) characteristic curves from continuously-distributed data
    • Metz CE, Herman BA, Shen JH. Maximum-likelihood estimation of receiver operating (ROC) characteristic curves from continuously-distributed data. Stat Med 1998;17:1033-53
    • (1998) Stat Med , vol.17 , pp. 1033-1053
    • Metz, C.E.1    Herman, B.A.2    Shen, J.H.3
  • 12
    • 0033740082 scopus 로고    scopus 로고
    • Experimental evaluation of a-Se and CdTe flat-panel x-ray detectors for digital radiography and fluoroscopy
    • Adachi S, Hori N, Sato K, et al. Experimental evaluation of a-Se and CdTe flat-panel x-ray detectors for digital radiography and fluoroscopy. Proc SPIE 2000;3977:38-47
    • (2000) Proc SPIE , vol.3977 , pp. 38-47
    • Adachi, S.1    Hori, N.2    Sato, K.3
  • 13
    • 0037393386 scopus 로고    scopus 로고
    • An experimental comparison of detector performance for direct and indirect digital radiography systems
    • Samei E, Flynn MJ. An experimental comparison of detector performance for direct and indirect digital radiography systems. Med Phys 2003;30:608-22
    • (2003) Med Phys , vol.30 , pp. 608-622
    • Samei, E.1    Flynn, M.J.2
  • 14
    • 0030820128 scopus 로고    scopus 로고
    • Flat-panel x-ray detector using amorphous silicon technology: Reduced radiation dose for the detection of foreign bodies
    • Voelk M, Strotzer M, Gmeinwieser J, et al. Flat-panel x-ray detector using amorphous silicon technology: reduced radiation dose for the detection of foreign bodies. Investig Radiol 1997;32:373-77
    • (1997) Investig Radiol , vol.32 , pp. 373-377
    • Voelk, M.1    Strotzer, M.2    Gmeinwieser, J.3
  • 15
    • 0025845656 scopus 로고
    • X-ray imaging using amorphous selenium: A photoinduced discharge readout method for digital mammography
    • Rowlands JA, Hunter DM, Araj N. X-ray imaging using amorphous selenium: a photoinduced discharge readout method for digital mammography. Med Phys 1991;18:421-31
    • (1991) Med Phys , vol.18 , pp. 421-431
    • Rowlands, J.A.1    Hunter, D.M.2    Araj, N.3
  • 16
    • 0033015756 scopus 로고    scopus 로고
    • Principles of digital radiography with large-area, electronically readable detectors: A review of the basics
    • Chotas HG, Dobbins JT, Rabin CE. Principles of digital radiography with large-area, electronically readable detectors: a review of the basics. Radiology 1999;210:595-99
    • (1999) Radiology , vol.210 , pp. 595-599
    • Chotas, H.G.1    Dobbins, J.T.2    Rabin, C.E.3
  • 17
    • 0037321857 scopus 로고    scopus 로고
    • imaging performance of amorphous selenium based flat-panel detectors for digital mammography: Characterization of a small area prototype detector
    • Zhao W, Ji WG, Debrie A, et al. imaging performance of amorphous selenium based flat-panel detectors for digital mammography: characterization of a small area prototype detector. Med Phys 2003;30:254-63
    • (2003) Med Phys , vol.30 , pp. 254-263
    • Zhao, W.1    Ji, W.G.2    Debrie, A.3
  • 18
    • 0021248140 scopus 로고
    • Characterization of the veiling glare PSF in x-ray image intensified fluoroscopy
    • Seibert JA, Nalrioglu O, Roeck WW. Characterization of the veiling glare PSF in x-ray image intensified fluoroscopy. Med Phys 1984;11:172-79
    • (1984) Med Phys , vol.11 , pp. 172-179
    • Seibert, J.A.1    Nalrioglu, O.2    Roeck, W.W.3
  • 19
    • 0032767558 scopus 로고    scopus 로고
    • Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography
    • Aufrichtig R. Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography. Med Phys 1999;26:1349-58
    • (1999) Med Phys , vol.26 , pp. 1349-1358
    • Aufrichtig, R.1
  • 20
    • 0034051282 scopus 로고    scopus 로고
    • Digital radiography with a large-area, amorphous-silicon, flat-panel x-ray detector system
    • Spahn M, Strotzer M, Volk M, et al. Digital radiography with a large-area, amorphous-silicon, flat-panel x-ray detector system. Investig Radiol 2000;35:260-66
    • (2000) Investig Radiol , vol.35 , pp. 260-266
    • Spahn, M.1    Strotzer, M.2    Volk, M.3
  • 21
    • 0035119131 scopus 로고    scopus 로고
    • Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography
    • Floyd CE, Warp RJ, Dobbins JT, et al. Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography. Radiology 2001;218:683-88
    • (2001) Radiology , vol.218 , pp. 683-688
    • Floyd, C.E.1    Warp, R.J.2    Dobbins, J.T.3
  • 22
    • 10744230069 scopus 로고    scopus 로고
    • Difference in configuration of ruptured and unruptured intracranial aneurysms determined by biplanar digital subtraction angiography
    • Beck J, Rohde S, el Beltagy M, et al. Difference in configuration of ruptured and unruptured intracranial aneurysms determined by biplanar digital subtraction angiography. Acta Neurochir (Wien) 2003;145:861-65
    • (2003) Acta Neurochir (Wien) , vol.145 , pp. 861-865
    • Beck, J.1    Rohde, S.2    el Beltagy, M.3
  • 23
    • 4544269899 scopus 로고    scopus 로고
    • Radiation doses in interventional radiology procedures: The RAD-IR Study. Part III: Dosimetric performance of the interventional fluoroscopy units
    • Balter S, Schueler BA, Miller DL, et al. Radiation doses in interventional radiology procedures: the RAD-IR Study. Part III: Dosimetric performance of the interventional fluoroscopy units. J Vasc Interv Radiol 2004;15:919-26
    • (2004) J Vasc Interv Radiol , vol.15 , pp. 919-926
    • Balter, S.1    Schueler, B.A.2    Miller, D.L.3
  • 24
    • 0038294287 scopus 로고    scopus 로고
    • Radiation doses in interventional radiology procedures: The RAD-IR study, part II: skin dose
    • Miller DL, Balter S, Cole PE, et al. Radiation doses in interventional radiology procedures: the RAD-IR study, part II: skin dose. J Vasc Interv Radiol 2003;14:977-90
    • (2003) J Vasc Interv Radiol , vol.14 , pp. 977-990
    • Miller, D.L.1    Balter, S.2    Cole, P.E.3
  • 25
    • 0037833538 scopus 로고    scopus 로고
    • Radiation doses in interventional radiology procedures: The RAD-IR study: part I: overall measures of dose
    • Miller DL, Balter S, Cole PE, et al. Radiation doses in interventional radiology procedures: the RAD-IR study: part I: overall measures of dose. J Vasc Interv Radiol 2003;14:711-27
    • (2003) J Vasc Interv Radiol , vol.14 , pp. 711-727
    • Miller, D.L.1    Balter, S.2    Cole, P.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.