메뉴 건너뛰기




Volumn 62, Issue 4, 2007, Pages 1069-1070

Letters to the editor [12]

Author keywords

[No Author keywords available]

Indexed keywords

ACUTE HEART FAILURE; AORTA FLOW; ASCENDING AORTA; DOPPLER ECHOCARDIOGRAPHY; EMERGENCY CARE; EMERGENCY HEALTH SERVICE; HEART OUTPUT; HEART STROKE VOLUME; HEMODYNAMIC MONITORING; HUMAN; LETTER; MONITOR; NON INVASIVE MEASUREMENT; PRIORITY JOURNAL; PULSE PRESSURE; SWAN GANZ CATHETER; SYSTOLIC BLOOD PRESSURE; ULTRASONIC CARDIAC OUTPUT MONITOR;

EID: 34247259046     PISSN: 00225282     EISSN: 15298809     Source Type: Journal    
DOI: 10.1097/TA.0b013e3180342979     Document Type: Letter
Times cited : (3)

References (6)
  • 1
    • 33748750333 scopus 로고    scopus 로고
    • Arterial pulse pressure and its association with reduced stroke volume during progressive central hypovolemia
    • Convertino VA, Cooke WH, Holcomb JB. Arterial pulse pressure and its association with reduced stroke volume during progressive central hypovolemia. J Trauma. 2006;61:629-634.
    • (2006) J Trauma , vol.61 , pp. 629-634
    • Convertino, V.A.1    Cooke, W.H.2    Holcomb, J.B.3
  • 2
    • 33644545393 scopus 로고    scopus 로고
    • Arterial pulse pressure and its association with reduced stroke volume during progressive central hypovolemia
    • Shochat M, Charach G, Meyler S, et al. Arterial pulse pressure and its association with reduced stroke volume during progressive central hypovolemia. Cardiovasc Revasc Med. 2006;7:41-45.
    • (2006) Cardiovasc Revasc Med , vol.7 , pp. 41-45
    • Shochat, M.1    Charach, G.2    Meyler, S.3
  • 3
    • 14544292461 scopus 로고    scopus 로고
    • Testing the reliability of a new ultrasonic cardiac output monitor, the USCOM, by using aortic flowprobes in anesthetized dogs
    • Critchley LA, Peng ZY, Fok BS, Lee A, Phillips RA. Testing the reliability of a new ultrasonic cardiac output monitor, the USCOM, by using aortic flowprobes in anesthetized dogs. Anesth Analg. 2005;100:748-753.
    • (2005) Anesth Analg , vol.100 , pp. 748-753
    • Critchley, L.A.1    Peng, Z.Y.2    Fok, B.S.3    Lee, A.4    Phillips, R.A.5
  • 4
    • 25144520471 scopus 로고    scopus 로고
    • Non-invasive cardiac output determination by two-dimensional independent Doppler during and after cardiac surgery
    • Knobloch K, Lichtenberg A, Winterhalter M, Rossner D, Pichlmaier M, Phillips R. Non-invasive cardiac output determination by two-dimensional independent Doppler during and after cardiac surgery. Ann Thorac Surg. 2005;80:1479-1483.
    • (2005) Ann Thorac Surg , vol.80 , pp. 1479-1483
    • Knobloch, K.1    Lichtenberg, A.2    Winterhalter, M.3    Rossner, D.4    Pichlmaier, M.5    Phillips, R.6
  • 5
    • 14844354490 scopus 로고    scopus 로고
    • Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit
    • Tan HL, Pinder M, Parsons R, Roberts B, van Heerden PV. Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit. Br J Anaesth. 2005;94:287-291.
    • (2005) Br J Anaesth , vol.94 , pp. 287-291
    • Tan, H.L.1    Pinder, M.2    Parsons, R.3    Roberts, B.4    van Heerden, P.V.5
  • 6
    • 30044435121 scopus 로고    scopus 로고
    • Non-invasive determination of cardiac output by continuous wave Doppler in air rescue service
    • Knobloch K, Hubrich V, Rohmann P, et al. Non-invasive determination of cardiac output by continuous wave Doppler in air rescue service. Anasthesiol Intensivmed Notfallmed Schmerzther. 2005;40:750-755.
    • (2005) Anasthesiol Intensivmed Notfallmed Schmerzther , vol.40 , pp. 750-755
    • Knobloch, K.1    Hubrich, V.2    Rohmann, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.