메뉴 건너뛰기




Volumn 125, Issue 4, 2007, Pages 483-486

Preventing posterior capsular opacification with an endocapsular equator ring in a young human eye: 2-Year follow-up

Author keywords

[No Author keywords available]

Indexed keywords

POLY(METHYL METHACRYLATE); SILICONE;

EID: 34247164552     PISSN: 00039950     EISSN: 00039950     Source Type: Journal    
DOI: 10.1001/archopht.125.4.483     Document Type: Article
Times cited : (20)

References (16)
  • 1
    • 0041856088 scopus 로고    scopus 로고
    • Posterior capsule opacification after phacoemulsification: Silicone CeeOn edge versus acrylate AcrySof intraocular lens
    • Prosdocimo G, Tassinari G, Sala M, et al. Posterior capsule opacification after phacoemulsification: silicone CeeOn edge versus acrylate AcrySof intraocular lens. J Cataract Refract Surg. 2003;29:1551-1555.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1551-1555
    • Prosdocimo, G.1    Tassinari, G.2    Sala, M.3
  • 2
    • 0024205810 scopus 로고
    • Observations on lens epithelial cell and their removal in anterior capsule specimens
    • Hara T, Hara T. Observations on lens epithelial cell and their removal in anterior capsule specimens. Arch Ophthalmol. 1988;106:1683-1687.
    • (1988) Arch Ophthalmol , vol.106 , pp. 1683-1687
    • Hara, T.1    Hara, T.2
  • 3
    • 0033783243 scopus 로고    scopus 로고
    • Effect of mitomycin-C on posterior capsule opacification in rabbit eyes
    • Chung HS, Lim SJ, Kim HB. Effect of mitomycin-C on posterior capsule opacification in rabbit eyes. J Cataract Refract Surg. 2000;26:1537-1542.
    • (2000) J Cataract Refract Surg , vol.26 , pp. 1537-1542
    • Chung, H.S.1    Lim, S.J.2    Kim, H.B.3
  • 4
    • 0034127734 scopus 로고    scopus 로고
    • Double-masked prospective ocular safety study of a lens epithelial cell antibody to prevent posterior capsule opacification
    • Meacock WR, Spalton DJ, Hollick EJ, Boyce JF, Barman S, Sanguinetti G. Double-masked prospective ocular safety study of a lens epithelial cell antibody to prevent posterior capsule opacification. J Cataract Refract Surg. 2000;26:716-721.
    • (2000) J Cataract Refract Surg , vol.26 , pp. 716-721
    • Meacock, W.R.1    Spalton, D.J.2    Hollick, E.J.3    Boyce, J.F.4    Barman, S.5    Sanguinetti, G.6
  • 5
    • 0037360831 scopus 로고    scopus 로고
    • Prevention of posterior capsule opacification using capsular tension ring for zonular defects in cataract surgery
    • D'Eliseo D, Pastena B, Longanesi L, Grisanti F, Negrini V. Prevention of posterior capsule opacification using capsular tension ring for zonular defects in cataract surgery. Eur J Ophthalmol. 2003;13:151-154.
    • (2003) Eur J Ophthalmol , vol.13 , pp. 151-154
    • D'Eliseo, D.1    Pastena, B.2    Longanesi, L.3    Grisanti, F.4    Negrini, V.5
  • 6
    • 0034827421 scopus 로고    scopus 로고
    • Capsular bending ring to prevent posterior capsule opacification: 2 year follow-up
    • Nishi O, Nishi K, Menapace R, Akura J. Capsular bending ring to prevent posterior capsule opacification: 2 year follow-up. J Cataract Refract Surg. 2001;27:1359-1365.
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1359-1365
    • Nishi, O.1    Nishi, K.2    Menapace, R.3    Akura, J.4
  • 8
    • 4944259292 scopus 로고    scopus 로고
    • Effect of intraocular lenses on preventing posterior capsule opacification: Design versus material
    • Nishi O, Nishi K, Osakabe Y. Effect of intraocular lenses on preventing posterior capsule opacification: design versus material. J Cataract Refract Surg. 2004;30:2170-2176.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 2170-2176
    • Nishi, O.1    Nishi, K.2    Osakabe, Y.3
  • 9
    • 0025784515 scopus 로고
    • Equator ring for maintenance of the completely circular contour of the capsular bag equator after cataract removal
    • Hara T, Hara T, Yamada Y. Equator ring for maintenance of the completely circular contour of the capsular bag equator after cataract removal. Ophthalmic Surg. 1991;22:358-359.
    • (1991) Ophthalmic Surg , vol.22 , pp. 358-359
    • Hara, T.1    Hara, T.2    Yamada, Y.3
  • 10
    • 0028805830 scopus 로고
    • Efficacy of equator rings in an experimental rabbit eyes
    • Hara T, Hara T, Sakanishi K, Yamada Y. Efficacy of equator rings in an experimental rabbit eyes. Arch Ophthalmol. 1995;113:1060-1065.
    • (1995) Arch Ophthalmol , vol.113 , pp. 1060-1065
    • Hara, T.1    Hara, T.2    Sakanishi, K.3    Yamada, Y.4
  • 11
    • 0031899915 scopus 로고    scopus 로고
    • Equator ring efficacy in maintaining capsular bag integrity and transparency after cataract removal in monkey eyes
    • Hashizoe M, Hara T, Ogura Y, Sakanishi K, Honda Y, Hara T. Equator ring efficacy in maintaining capsular bag integrity and transparency after cataract removal in monkey eyes. Graefes Arch Clin Exp Ophthalmol. 1998;236:375-379.
    • (1998) Graefes Arch Clin Exp Ophthalmol , vol.236 , pp. 375-379
    • Hashizoe, M.1    Hara, T.2    Ogura, Y.3    Sakanishi, K.4    Honda, Y.5    Hara, T.6
  • 12
    • 0031890039 scopus 로고    scopus 로고
    • The inhibition of lens epithelial cell migration by a discontinuous capsular bend created by a band-shaped circular loop or a capsule-bending ring
    • Nishi O, Nishi K, Mano C, Ichihara M, Honda T. The inhibition of lens epithelial cell migration by a discontinuous capsular bend created by a band-shaped circular loop or a capsule-bending ring. Ophthalmic Surg Lasers. 1998;29:119-125.
    • (1998) Ophthalmic Surg Lasers , vol.29 , pp. 119-125
    • Nishi, O.1    Nishi, K.2    Mano, C.3    Ichihara, M.4    Honda, T.5
  • 13
    • 0029866388 scopus 로고    scopus 로고
    • Retrospective survey of surgical outcome on rhegmatogenous retinal detachments associated with atopic dermatitis
    • Azuma N, Hida T, Katsura H, Takeuchi S, Danjo S, Tano Y. Retrospective survey of surgical outcome on rhegmatogenous retinal detachments associated with atopic dermatitis. Arch Ophthalmol. 1996;114:281-285.
    • (1996) Arch Ophthalmol , vol.114 , pp. 281-285
    • Azuma, N.1    Hida, T.2    Katsura, H.3    Takeuchi, S.4    Danjo, S.5    Tano, Y.6
  • 14
    • 0032100759 scopus 로고    scopus 로고
    • In vivo quantitative measurement of posterior capsular opacification after extracapsular cataract surgery
    • Hayashi K, Hayashi H, Nakao F, Hayashi F. In vivo quantitative measurement of posterior capsular opacification after extracapsular cataract surgery. Am J Ophthalmol. 1998;125:837-843.
    • (1998) Am J Ophthalmol , vol.125 , pp. 837-843
    • Hayashi, K.1    Hayashi, H.2    Nakao, F.3    Hayashi, F.4
  • 15
    • 3543113323 scopus 로고    scopus 로고
    • Personal phacoemulsification techniques
    • Buratto L, ed, Thorofare, NJ: Slack Inc;
    • Hara T. Personal phacoemulsification techniques. In: Buratto L, ed. Phacoemulsification: Principles and Techniques. Thorofare, NJ: Slack Inc; 1997:427-432.
    • (1997) Phacoemulsification: Principles and Techniques , pp. 427-432
    • Hara, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.