-
1
-
-
0012039211
-
Standard 210
-
Arlington Heights, Ill.: Air Movement and Control Association, Inc.
-
AMCA. 1985. Standard 210, Laboratory Methods of Testing Fans for Rating. Arlington Heights, Ill.: Air Movement and Control Association, Inc.
-
(1985)
Laboratory Methods of Testing Fans for Rating
-
-
-
2
-
-
0012092146
-
ANSI/ASHRAE Standard 116-1995
-
Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
-
ASHRAE. 1995. ANSI/ASHRAE Standard 116-1995, Methods of Testing for Seasonal Efficiency of Unitary Air Conditioners and Heat Pumps. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
-
(1995)
Methods of Testing for Seasonal Efficiency of Unitary Air Conditioners and Heat Pumps
-
-
-
4
-
-
0027874629
-
The effects of outdoor fan airflow on the frost/defrost performance of an air source heat pump
-
ASME Winter Annual Meeting, New Orleans, Louisiana, November
-
Payne, W.V., and D.L. O'Neal. 1993. The effects of outdoor fan airflow on the frost/defrost performance of an air source heat pump. Heat Pump and Refrigeration Systems Design, Analysis and Applications, AES-Volume 29. ASME Winter Annual Meeting, New Orleans, Louisiana, November.
-
(1993)
Heat Pump and Refrigeration Systems Design, Analysis and Applications
, vol.AES-29
-
-
Payne, W.V.1
O'Neal, D.L.2
-
5
-
-
4243371807
-
-
M.S. thesis, Texas A and M University, Department of Mechanical Engineering, College Station, Tex
-
Watters, R.J. 2001. Evaluation of fin staging methods for minimizing coil frost accumulation. M.S. thesis, Texas A and M University, Department of Mechanical Engineering, College Station, Tex.
-
(2001)
Evaluation of fin staging methods for minimizing coil frost accumulation
-
-
Watters, R.J.1
-
6
-
-
0035569806
-
Effect of fin staging on frost/defrost performance of a two-row heat pump evaporator at standard heat pump test conditions
-
Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
-
Watters, R.J., D.L. O'Neal, and J. Yang. 2001a. Effect of fin staging on frost/defrost performance of a two-row heat pump evaporator at standard heat pump test conditions. ASHRAE Transactions Vol. 107(2). Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
-
(2001)
ASHRAE Transactions
, vol.107
, Issue.2
-
-
Watters, R.J.1
O'Neal, D.L.2
Yang, J.3
-
7
-
-
0035571434
-
Effect of fin staging on frost/defrost performance of a two-row heat pump evaporator under heavy frosting conditions
-
Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
-
Watters, R.J., D.L. O'Neal, and J. Yang. 2001b. Effect of fin staging on frost/defrost performance of a two-row heat pump evaporator under heavy frosting conditions. ASHRAE Transactions 107(2). Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
-
(2001)
ASHRAE Transactions
, vol.107
, Issue.2
-
-
Watters, R.J.1
O'Neal, D.L.2
Yang, J.3
|