메뉴 건너뛰기




Volumn 31, Issue 4, 2007, Pages 290-300

Comparing oxygen transfer performance between three membrane oxygenators: Effect of temperature changes during cardiopulmonary bypass

Author keywords

Cardiac surgery; Cardiopulmonary bypass; Gas transfer rate; Membrane oxygenator; Perfusion; Temperature

Indexed keywords

BLOOD; BLOOD PRESSURE; CARDIOVASCULAR SURGERY; MERCURY (METAL); OXYGEN SUPPLY; OXYGENATION; OXYGENATORS; RESPIRATORY THERAPY; VANADIUM DIOXIDE;

EID: 34247106696     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2007.00379.x     Document Type: Article
Times cited : (20)

References (22)
  • 5
    • 34247162107 scopus 로고    scopus 로고
    • Oxygen transfer study of the Dideco D703 during elective cardiac surgery
    • Pierrel N, Morrison S, von Segesser LK. Oxygen transfer study of the Dideco D703 during elective cardiac surgery. SwissPerfusion 1998;2:33-7.
    • (1998) SwissPerfusion , vol.2 , pp. 33-37
    • Pierrel, N.1    Morrison, S.2    von Segesser, L.K.3
  • 6
    • 0026721383 scopus 로고
    • A comparison of two oxygen transfer strategies: Bentley Univox and the Bard HF5000
    • Fried DW. A comparison of two oxygen transfer strategies: Bentley Univox and the Bard HF5000. Perfusion 1992;7:141-8.
    • (1992) Perfusion , vol.7 , pp. 141-148
    • Fried, D.W.1
  • 8
    • 0027051001 scopus 로고
    • Oxygen transfer performance of a new Sarns membrane oxygenator
    • Fried DW, Bell-Thomson J. Oxygen transfer performance of a new Sarns membrane oxygenator. Perfusion 1992;7:263-71.
    • (1992) Perfusion , vol.7 , pp. 263-271
    • Fried, D.W.1    Bell-Thomson, J.2
  • 9
    • 0035190067 scopus 로고    scopus 로고
    • Comparison of three commercially available hollow fiber oxygenators: Gas transfer performance and biocompatibility
    • de Vroege R, Wagemakers M, TeVelthuis H, et al. Comparison of three commercially available hollow fiber oxygenators: gas transfer performance and biocompatibility. ASAIO J 2001;47:37-44.
    • (2001) ASAIO J , vol.47 , pp. 37-44
    • de Vroege, R.1    Wagemakers, M.2    TeVelthuis, H.3
  • 10
    • 0346127056 scopus 로고    scopus 로고
    • Principles of oxygenator function: Gas exchange, heat transfer, and operation
    • Gravlee GP, Davis RF, Kurusz M, Utley JR, eds, Philadelphia, PA: Lippincott Williams & Wilkins
    • High KM, Bashein G, Kurusz M. Principles of oxygenator function: gas exchange, heat transfer, and operation. In: Gravlee GP, Davis RF, Kurusz M, Utley JR, eds. Cardiopulmonary Bypass: Principles and Practice. Philadelphia, PA: Lippincott Williams & Wilkins, 2000;49-68.
    • (2000) Cardiopulmonary Bypass: Principles and Practice , pp. 49-68
    • High, K.M.1    Bashein, G.2    Kurusz, M.3
  • 13
    • 34247168951 scopus 로고    scopus 로고
    • Ex-vivo evaluation of a hollow fibre membrane oxygenator compared between two animal models: Porcine and bovine
    • Jegger D, Mueller XM, Tevaearai HT, Tucker OP, Horisberger J, von Segesser LK. Ex-vivo evaluation of a hollow fibre membrane oxygenator compared between two animal models: porcine and bovine. Med Phys 2000;27:1441.
    • (2000) Med Phys , vol.27 , pp. 1441
    • Jegger, D.1    Mueller, X.M.2    Tevaearai, H.T.3    Tucker, O.P.4    Horisberger, J.5    von Segesser, L.K.6
  • 15
    • 0030859666 scopus 로고    scopus 로고
    • Clinical evaluation of six hollow-fibre membrane oxygenators
    • Visser C, de Jong DS. Clinical evaluation of six hollow-fibre membrane oxygenators. Perfusion 1997;12:357-68.
    • (1997) Perfusion , vol.12 , pp. 357-368
    • Visser, C.1    de Jong, D.S.2
  • 16
    • 0027174470 scopus 로고
    • The clinical significance of the oxygen transfer slope
    • Fried DW, Bell-Thomson J. The clinical significance of the oxygen transfer slope. Perfusion 1993;8:169-75.
    • (1993) Perfusion , vol.8 , pp. 169-175
    • Fried, D.W.1    Bell-Thomson, J.2
  • 17
    • 29244479980 scopus 로고    scopus 로고
    • Ex vivo evaluation of a new extracorporeal lung assist device: NovaLung® membrane oxygenator
    • Jegger D, Revelly J-P, Horisberger J, et al. Ex vivo evaluation of a new extracorporeal lung assist device: NovaLung® membrane oxygenator. Int J Artif Organs 2005;28:985-99.
    • (2005) Int J Artif Organs , vol.28 , pp. 985-999
    • Jegger, D.1    Revelly, J.-P.2    Horisberger, J.3
  • 18
    • 5444240838 scopus 로고    scopus 로고
    • Ex vivo evaluation of a new neonatal/infant oxygenator: Comparison of the Terumo CAPIOX® Baby RX with Dideco Lilliput 1 and Polystan Safe Micro I the piglet model
    • Dubois J, Jamaer L, Mees U, et al. Ex vivo evaluation of a new neonatal/infant oxygenator: comparison of the Terumo CAPIOX® Baby RX with Dideco Lilliput 1 and Polystan Safe Micro I the piglet model. Perfusion 2004;19:315-21.
    • (2004) Perfusion , vol.19 , pp. 315-321
    • Dubois, J.1    Jamaer, L.2    Mees, U.3
  • 19
    • 4444226266 scopus 로고    scopus 로고
    • Compact intra- and extracorporeal oxygenator developments
    • Cattaneo G, Strau BA, Reul H. Compact intra- and extracorporeal oxygenator developments. Perfusion 2004;19:251-5.
    • (2004) Perfusion , vol.19 , pp. 251-255
    • Cattaneo, G.1    Strau, B.A.2    Reul, H.3
  • 20
    • 2542439065 scopus 로고    scopus 로고
    • Development of a novel polyimide hollow-fiber oxygenator
    • Niwa M, Kawakai H, Nagaoka S, et al. Development of a novel polyimide hollow-fiber oxygenator. Artif Organs 2004;28:487-95.
    • (2004) Artif Organs , vol.28 , pp. 487-495
    • Niwa, M.1    Kawakai, H.2    Nagaoka, S.3
  • 21
    • 0035190067 scopus 로고    scopus 로고
    • Comparison of three commercially available hollow fiber oxygenators: Gas transfer performance and biocompatibility
    • de Vroege R, Wagemakers M, TeVelthuis H, et al. Comparison of three commercially available hollow fiber oxygenators: gas transfer performance and biocompatibility. ASAIO J 2001;47:37-44.
    • (2001) ASAIO J , vol.47 , pp. 37-44
    • de Vroege, R.1    Wagemakers, M.2    TeVelthuis, H.3
  • 22
    • 0032723938 scopus 로고    scopus 로고
    • In vivo evaluation of a phosphorylcholine coated cardiopulmonary bypass circuit
    • De Somer F, Van Belleghem Y, Foubert L, et al. In vivo evaluation of a phosphorylcholine coated cardiopulmonary bypass circuit. J Extra Corpor Technol 1999;31:62-6.
    • (1999) J Extra Corpor Technol , vol.31 , pp. 62-66
    • De Somer, F.1    Van Belleghem, Y.2    Foubert, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.