2
-
-
1142285433
-
Osseointegration of a hydroxyapatite-coated multilayered mesh stem
-
Kusakabe H., Sakamaki T., Nihei K., Oyama Y., Yanagimoto S., et al. Osseointegration of a hydroxyapatite-coated multilayered mesh stem. Biomaterials 25 15 (2004) 2957-2969
-
(2004)
Biomaterials
, vol.25
, Issue.15
, pp. 2957-2969
-
-
Kusakabe, H.1
Sakamaki, T.2
Nihei, K.3
Oyama, Y.4
Yanagimoto, S.5
-
3
-
-
0033984564
-
Long-term change of hydroxyapatite-coated dental implants
-
Baltag I., Watanabe K., Kusakari H., Taguchi N., Miyakawa O., Kobayashi M., et al. Long-term change of hydroxyapatite-coated dental implants. J Biomed Mater Res 53 1 (2000) 76-85
-
(2000)
J Biomed Mater Res
, vol.53
, Issue.1
, pp. 76-85
-
-
Baltag, I.1
Watanabe, K.2
Kusakari, H.3
Taguchi, N.4
Miyakawa, O.5
Kobayashi, M.6
-
4
-
-
0033014324
-
Degradation of hydroxyapatite, fluorapatite, and fluorhydroxyapatite coatings of dental implants in dogs
-
Gineste L., Gineste M., Ranz X., Ellefterion A., Guilhem A., Rouquet N., et al. Degradation of hydroxyapatite, fluorapatite, and fluorhydroxyapatite coatings of dental implants in dogs. J Biomed Mater Res 48 3 (1999) 224-234
-
(1999)
J Biomed Mater Res
, vol.48
, Issue.3
, pp. 224-234
-
-
Gineste, L.1
Gineste, M.2
Ranz, X.3
Ellefterion, A.4
Guilhem, A.5
Rouquet, N.6
-
5
-
-
0030631536
-
Resorption of hydroxyapatite and fluorapatite ceramic coatings on weight-bearing implants: a quantitative and morphological study in dogs
-
Overgaard S., Lind M., Josephsen K., Maunsbach A.B., Bunger C., and Soballe K. Resorption of hydroxyapatite and fluorapatite ceramic coatings on weight-bearing implants: a quantitative and morphological study in dogs. J Biomed Mater Res 39 1 (1998) 141-152
-
(1998)
J Biomed Mater Res
, vol.39
, Issue.1
, pp. 141-152
-
-
Overgaard, S.1
Lind, M.2
Josephsen, K.3
Maunsbach, A.B.4
Bunger, C.5
Soballe, K.6
-
6
-
-
0031124259
-
Preparation and characterization of fluoride-substituted apatite
-
Jha L.J., Best S.M., Knowles J.C., Rehman I., and Santos J.D. Preparation and characterization of fluoride-substituted apatite. J Mater Sci-Mater M 8 4 (1997) 185-191
-
(1997)
J Mater Sci-Mater M
, vol.8
, Issue.4
, pp. 185-191
-
-
Jha, L.J.1
Best, S.M.2
Knowles, J.C.3
Rehman, I.4
Santos, J.D.5
-
7
-
-
1642363037
-
Influence of fluorapatite minor additions on behavior of hydroxyapatite ceramics
-
Barinov S.M., Rustichelli F., Orlovskii V.P., Lodini A., Oscarsson S., Firstov S.A., et al. Influence of fluorapatite minor additions on behavior of hydroxyapatite ceramics. J Mater Sci-Mater M 15 3 (2004) 291-296
-
(2004)
J Mater Sci-Mater M
, vol.15
, Issue.3
, pp. 291-296
-
-
Barinov, S.M.1
Rustichelli, F.2
Orlovskii, V.P.3
Lodini, A.4
Oscarsson, S.5
Firstov, S.A.6
-
8
-
-
1142285439
-
Sol-gel derived fluor-hydroxyapatite biocoatings on zirconia substrate
-
Kim H.W., Kong Y.M., Bae C.J., Noh Y.J., and Kim H.E. Sol-gel derived fluor-hydroxyapatite biocoatings on zirconia substrate. Biomaterials 25 15 (2004) 2919-2926
-
(2004)
Biomaterials
, vol.25
, Issue.15
, pp. 2919-2926
-
-
Kim, H.W.1
Kong, Y.M.2
Bae, C.J.3
Noh, Y.J.4
Kim, H.E.5
-
9
-
-
20644443888
-
In vitro behavior of osteoblast like cells the effect of F-content in fluoridated hydroxyapatite coating
-
Cheng K., Weng W., Wang H., and Zhang S. In vitro behavior of osteoblast like cells the effect of F-content in fluoridated hydroxyapatite coating. Biomaterials 26 32 (2005) 6288-6295
-
(2005)
Biomaterials
, vol.26
, Issue.32
, pp. 6288-6295
-
-
Cheng, K.1
Weng, W.2
Wang, H.3
Zhang, S.4
-
10
-
-
0032048317
-
Deposition of hydroxyapatite thin films by excimer laser ablation
-
Fernandez-Pradas J.M., Sardin G., Cleries L., Serra P., Ferrater C., and Morenza J.L. Deposition of hydroxyapatite thin films by excimer laser ablation. Thin Solid Films 317 1-2 (1998) 393-396
-
(1998)
Thin Solid Films
, vol.317
, Issue.1-2
, pp. 393-396
-
-
Fernandez-Pradas, J.M.1
Sardin, G.2
Cleries, L.3
Serra, P.4
Ferrater, C.5
Morenza, J.L.6
-
11
-
-
0030087954
-
Influence of annealing temperature on RF magnetron sputtered calcium phosphate coatings
-
Van Dijk K., Schaeken H.G., Wolke J.G.C., and Jansen J.A. Influence of annealing temperature on RF magnetron sputtered calcium phosphate coatings. Biomaterials 17 4 (1996) 405-410
-
(1996)
Biomaterials
, vol.17
, Issue.4
, pp. 405-410
-
-
Van Dijk, K.1
Schaeken, H.G.2
Wolke, J.G.C.3
Jansen, J.A.4
-
12
-
-
0030736017
-
Plasma sprayed hydroxyapatite (HA) coatings produced with flame spheroidised powders
-
Khor K.A., and Cheang P. Plasma sprayed hydroxyapatite (HA) coatings produced with flame spheroidised powders. J Mater Process Technol 63 1-3 (1997) 271-276
-
(1997)
J Mater Process Technol
, vol.63
, Issue.1-3
, pp. 271-276
-
-
Khor, K.A.1
Cheang, P.2
-
13
-
-
0033895431
-
Electrophoretic hydroxyapatite coatings and fibres
-
Zhitomirsky I. Electrophoretic hydroxyapatite coatings and fibres. Mater Lett 42 4 (2000) 262-271
-
(2000)
Mater Lett
, vol.42
, Issue.4
, pp. 262-271
-
-
Zhitomirsky, I.1
-
14
-
-
2942729793
-
Evaluating interface strength of calcium phosphate sol-gel derived thin films to Ti6Al4V substrate
-
Gan L., Wang J., and Pilliar R.M. Evaluating interface strength of calcium phosphate sol-gel derived thin films to Ti6Al4V substrate. Biomaterials 26 2 (2005) 189-196
-
(2005)
Biomaterials
, vol.26
, Issue.2
, pp. 189-196
-
-
Gan, L.1
Wang, J.2
Pilliar, R.M.3
-
15
-
-
0036132146
-
Sol-gel hydroxyapatite coatings on stainless steel substrates
-
Liu D.M., Yang Q., and Troczynski T. Sol-gel hydroxyapatite coatings on stainless steel substrates. Biomaterials 23 3 (2002) 691-698
-
(2002)
Biomaterials
, vol.23
, Issue.3
, pp. 691-698
-
-
Liu, D.M.1
Yang, Q.2
Troczynski, T.3
-
16
-
-
0036532938
-
Hydroxyapatite coating on Ti6Al4V alloy using a sol-gel derived precursor
-
Hshieh M.F., Pwerng L.H., and Chin T.S. Hydroxyapatite coating on Ti6Al4V alloy using a sol-gel derived precursor. Mater Chem Phys 74 3 (2002) 245-250
-
(2002)
Mater Chem Phys
, vol.74
, Issue.3
, pp. 245-250
-
-
Hshieh, M.F.1
Pwerng, L.H.2
Chin, T.S.3
-
17
-
-
0037099180
-
Influence of the interface layer on the adhesion of pulsed laser deposited hydroxyapatite coatings on titanium alloy
-
Fernandez-Pradas J.M., Garcia-Cuenca M.V., Cleries L., Sardin G., and Morenza J.L. Influence of the interface layer on the adhesion of pulsed laser deposited hydroxyapatite coatings on titanium alloy. Appl Surf Sci 195 1-4 (2002) 31-37
-
(2002)
Appl Surf Sci
, vol.195
, Issue.1-4
, pp. 31-37
-
-
Fernandez-Pradas, J.M.1
Garcia-Cuenca, M.V.2
Cleries, L.3
Sardin, G.4
Morenza, J.L.5
-
18
-
-
19944382188
-
Molecular precursor method for thin film calcium phosphate coating on titanium
-
Takahashi K., Hayakawa T., Yoshinari M., Hara H., Mochizuki C., Sato M., et al. Molecular precursor method for thin film calcium phosphate coating on titanium. Thin Solid Films 484 1-2 (2005) 1-9
-
(2005)
Thin Solid Films
, vol.484
, Issue.1-2
, pp. 1-9
-
-
Takahashi, K.1
Hayakawa, T.2
Yoshinari, M.3
Hara, H.4
Mochizuki, C.5
Sato, M.6
-
19
-
-
0034308347
-
Surface roughness parameters as predictors of anchorage strength in bone: a critical analysis
-
Hansson S. Surface roughness parameters as predictors of anchorage strength in bone: a critical analysis. J Biomech 33 10 (2000) 1297-1303
-
(2000)
J Biomech
, vol.33
, Issue.10
, pp. 1297-1303
-
-
Hansson, S.1
-
20
-
-
0035877411
-
Dissolution response of hydroxyapatite coatings to residual stress
-
Han Y., Xu K., and Lu J. Dissolution response of hydroxyapatite coatings to residual stress. J Biomed Mater Res 55 4 (2001) 596-602
-
(2001)
J Biomed Mater Res
, vol.55
, Issue.4
, pp. 596-602
-
-
Han, Y.1
Xu, K.2
Lu, J.3
-
21
-
-
0034992460
-
Influence of residual stress on bonding strength and fracture of plasma-sprayed hydroxyapatite coatings on Ti-6Al-4V substrate
-
Yang Y.C., and Chang E. Influence of residual stress on bonding strength and fracture of plasma-sprayed hydroxyapatite coatings on Ti-6Al-4V substrate. Biomaterials 22 13 (2001) 1827-1836
-
(2001)
Biomaterials
, vol.22
, Issue.13
, pp. 1827-1836
-
-
Yang, Y.C.1
Chang, E.2
-
22
-
-
0037461131
-
-
Weng W., Zhang S., Cheng K., Qu H., Du P., Shen G., et al. Surf Coat Technol 167 2-3 (2003) 292-296
-
(2003)
Surf Coat Technol
, vol.167
, Issue.2-3
, pp. 292-296
-
-
Weng, W.1
Zhang, S.2
Cheng, K.3
Qu, H.4
Du, P.5
Shen, G.6
-
23
-
-
33646139172
-
-
Zhang S., Zeng X.T., Wang Y.S., Cheng K., and Weng W. Surf Coat Technol 200 22-3 (2006) 6350-6354
-
(2006)
Surf Coat Technol
, vol.200
, Issue.22-3
, pp. 6350-6354
-
-
Zhang, S.1
Zeng, X.T.2
Wang, Y.S.3
Cheng, K.4
Weng, W.5
-
24
-
-
0024649447
-
Measurement of the ultimate shear strength of a metal-ceramic interface
-
Agrawal D.C., and Raj R. Measurement of the ultimate shear strength of a metal-ceramic interface. Acta Metall 37 4 (1989) 1265-1270
-
(1989)
Acta Metall
, vol.37
, Issue.4
, pp. 1265-1270
-
-
Agrawal, D.C.1
Raj, R.2
-
25
-
-
0025445627
-
Ultimate shear strength of copper-silica and nickel-silica interface
-
Agrawal D.C., and Raj R. Ultimate shear strength of copper-silica and nickel-silica interface. Mater Sci Engng A 126 1-2 (1990) 125-131
-
(1990)
Mater Sci Engng A
, vol.126
, Issue.1-2
, pp. 125-131
-
-
Agrawal, D.C.1
Raj, R.2
-
26
-
-
0030561069
-
Evaluating of sol-gel ceramics thin film for metal implant applications. II Adhesion and fatigue properties of Zirconia films on Ti-6Al-4V
-
Filiaggi M.J., Pilliar R.M., and Abdulla D. Evaluating of sol-gel ceramics thin film for metal implant applications. II Adhesion and fatigue properties of Zirconia films on Ti-6Al-4V. J Biomed Mater Res (Appl Biomater) 33 4 (1996) 239-256
-
(1996)
J Biomed Mater Res (Appl Biomater)
, vol.33
, Issue.4
, pp. 239-256
-
-
Filiaggi, M.J.1
Pilliar, R.M.2
Abdulla, D.3
-
27
-
-
0036133293
-
Measurement of the residual stress in a Pt-aluminide bond coat
-
Watanabe M., Mumm D.R., Chiras S., and Evans A.G. Measurement of the residual stress in a Pt-aluminide bond coat. Scripta Mater 46 1 (2002) 67-70
-
(2002)
Scripta Mater
, vol.46
, Issue.1
, pp. 67-70
-
-
Watanabe, M.1
Mumm, D.R.2
Chiras, S.3
Evans, A.G.4
-
28
-
-
0037680198
-
Measuring the adhesion of sol-gel derived coatings to a ductile substrate by an indentation method
-
Xie Y., and Hawthorne H.M. Measuring the adhesion of sol-gel derived coatings to a ductile substrate by an indentation method. Surf Coat Technol 172 1 (2003) 42-50
-
(2003)
Surf Coat Technol
, vol.172
, Issue.1
, pp. 42-50
-
-
Xie, Y.1
Hawthorne, H.M.2
-
29
-
-
0036119049
-
Properties of heat-treated calcium phosphate coatings deposited by high-velocity oxy-fuel spray
-
Li H., Khor K.A., and Cheang P. Properties of heat-treated calcium phosphate coatings deposited by high-velocity oxy-fuel spray. Biomaterials 23 10 (2002) 2105-2112
-
(2002)
Biomaterials
, vol.23
, Issue.10
, pp. 2105-2112
-
-
Li, H.1
Khor, K.A.2
Cheang, P.3
-
30
-
-
1942453208
-
Hydroxyapatite thin films grown by pulsed laser deposition and radio-frequency magnetron sputtering: comparative study
-
Nelea V., Morosanu C., Iliescu M., and Mihailescu I.N. Hydroxyapatite thin films grown by pulsed laser deposition and radio-frequency magnetron sputtering: comparative study. Appl Surf Sci 228 1-4 (2004) 346-356
-
(2004)
Appl Surf Sci
, vol.228
, Issue.1-4
, pp. 346-356
-
-
Nelea, V.1
Morosanu, C.2
Iliescu, M.3
Mihailescu, I.N.4
-
31
-
-
0345392761
-
Sintered hydroxyfluorapatites. Part II: Mechanical properties of solid solutions determined by microindentation
-
Gross K.A., and Rodriguez-Lorenzao L.M. Sintered hydroxyfluorapatites. Part II: Mechanical properties of solid solutions determined by microindentation. Biomaterials 25 7-8 (2004) 1385-1394
-
(2004)
Biomaterials
, vol.25
, Issue.7-8
, pp. 1385-1394
-
-
Gross, K.A.1
Rodriguez-Lorenzao, L.M.2
-
33
-
-
0028566279
-
Post-deposition treatment effects on hydroxyapatite vacuum plasma spray coatings
-
Brossa F., Cigada A., Chiesa R., Paracchini L., and Consonni C. Post-deposition treatment effects on hydroxyapatite vacuum plasma spray coatings. J Mater Sci-Mater M 5 (1994) 855-857
-
(1994)
J Mater Sci-Mater M
, vol.5
, pp. 855-857
-
-
Brossa, F.1
Cigada, A.2
Chiesa, R.3
Paracchini, L.4
Consonni, C.5
-
34
-
-
0031555507
-
In vitro and in vivo mechanical evaluations of plasma-sprayed hydroxyapatite coatings on titanium implants: the effect of coating characteristics
-
Yang C.Y., Lin R.M., Wang B.C., Lee T.M., Chang E., Hang Y.S., et al. In vitro and in vivo mechanical evaluations of plasma-sprayed hydroxyapatite coatings on titanium implants: the effect of coating characteristics. J Biomed Mater Res 37 3 (1997) 335-345
-
(1997)
J Biomed Mater Res
, vol.37
, Issue.3
, pp. 335-345
-
-
Yang, C.Y.1
Lin, R.M.2
Wang, B.C.3
Lee, T.M.4
Chang, E.5
Hang, Y.S.6
-
35
-
-
0035001735
-
Mechanical and histological evaluation of hydroxyapatite-coated and noncoated Ti6Al4V implants in tibia bone
-
Chang C.K., Wu J.S., Mao D.L., and Ding C.X. Mechanical and histological evaluation of hydroxyapatite-coated and noncoated Ti6Al4V implants in tibia bone. J Biomed Mater Res 56 1 (2001) 17-23
-
(2001)
J Biomed Mater Res
, vol.56
, Issue.1
, pp. 17-23
-
-
Chang, C.K.1
Wu, J.S.2
Mao, D.L.3
Ding, C.X.4
-
37
-
-
9744253169
-
-
Zhang S., Sun D., Fu Y., Du H., and Zhang Q. Diam Relat Mater 13 10 (2004) 1777-1784
-
(2004)
Diam Relat Mater
, vol.13
, Issue.10
, pp. 1777-1784
-
-
Zhang, S.1
Sun, D.2
Fu, Y.3
Du, H.4
Zhang, Q.5
-
38
-
-
20744456613
-
The F content in sol-gel derived FHA coatings: an XPS study
-
Cheng K., Zhang S., and Weng W. The F content in sol-gel derived FHA coatings: an XPS study. Surf Coat Technol 198 1-3 (2005) 237-241
-
(2005)
Surf Coat Technol
, vol.198
, Issue.1-3
, pp. 237-241
-
-
Cheng, K.1
Zhang, S.2
Weng, W.3
|