1
-
-
0030772658
-
Biomechanical performance of cutting edge surgical needles
-
Watkins F.H., London S.D., Neal J.G., Thacker J.G., and Edlich R.F. Biomechanical performance of cutting edge surgical needles. J Emerg Med 15 5 (1997) 679-685
-
(1997)
J Emerg Med
, vol.15
, Issue.5
, pp. 679-685
-
-
Watkins, F.H.1
London, S.D.2
Neal, J.G.3
Thacker, J.G.4
Edlich, R.F.5
-
2
-
-
0024552634
-
Surgical needle sharpness
-
Thacker J.G., Rodeheaver G.T., Towler M.A., and Edlich R.F. Surgical needle sharpness. Am J Surg 157 3 (1989) 334-339
-
(1989)
Am J Surg
, vol.157
, Issue.3
, pp. 334-339
-
-
Thacker, J.G.1
Rodeheaver, G.T.2
Towler, M.A.3
Edlich, R.F.4
-
3
-
-
0024619104
-
The sharpness of incision instruments in corneal tissue
-
Huebscher H.J., Gober G.J., and Lommatzsch P.K. The sharpness of incision instruments in corneal tissue. Ophthal Surg 20 2 (1989) 120-123
-
(1989)
Ophthal Surg
, vol.20
, Issue.2
, pp. 120-123
-
-
Huebscher, H.J.1
Gober, G.J.2
Lommatzsch, P.K.3
-
4
-
-
0033034838
-
An unusual case of suicide by stabbing with a falling weighted dagger
-
Ueno Y., Asano M., Nushida H., Adachi J., and Tatsuno Y. An unusual case of suicide by stabbing with a falling weighted dagger. Forensic Sci Int 101 3 (1999) 229-236
-
(1999)
Forensic Sci Int
, vol.101
, Issue.3
, pp. 229-236
-
-
Ueno, Y.1
Asano, M.2
Nushida, H.3
Adachi, J.4
Tatsuno, Y.5
-
5
-
-
0035314021
-
A biomechanical reconstruction of a wound caused by a glass shard: a case report
-
O'Callaghan P.T., Jones M.D., James D.S., Leadbeatter S., Evans S.L., and Nokes L.D.M. A biomechanical reconstruction of a wound caused by a glass shard: a case report. Forensic Sci Int 117 3 (2001) 221-231
-
(2001)
Forensic Sci Int
, vol.117
, Issue.3
, pp. 221-231
-
-
O'Callaghan, P.T.1
Jones, M.D.2
James, D.S.3
Leadbeatter, S.4
Evans, S.L.5
Nokes, L.D.M.6
-
6
-
-
0016785156
-
The dynamics of stab wounds
-
Knight B. The dynamics of stab wounds. Forensic Sci 6 3 (1975) 249-255
-
(1975)
Forensic Sci
, vol.6
, Issue.3
, pp. 249-255
-
-
Knight, B.1
-
7
-
-
84940993895
-
-
Saukko P, Knight B. Knight's Forensic pathology. Arnold; 2004.
-
-
-
-
8
-
-
0018253831
-
Stab wound dynamics: a recording technique for use in medico-legal investigations
-
Green M.A. Stab wound dynamics: a recording technique for use in medico-legal investigations. J Forensic Sci 18 3-4 (1978) 161-163
-
(1978)
J Forensic Sci
, vol.18
, Issue.3-4
, pp. 161-163
-
-
Green, M.A.1
-
9
-
-
10244270607
-
Experimental device for simulating traumatic brain injury resulting from linear accelerations
-
Gilchrist M.D. Experimental device for simulating traumatic brain injury resulting from linear accelerations. Strain 40 (2004) 180-192
-
(2004)
Strain
, vol.40
, pp. 180-192
-
-
Gilchrist, M.D.1
-
10
-
-
0038025904
-
The creation of three-dimensional finite element models for simulating head impact biomechanics
-
Horgan T.J., and Gilchrist M.D. The creation of three-dimensional finite element models for simulating head impact biomechanics. Int J Crashworthiness 8 4 (2003) 353-366
-
(2003)
Int J Crashworthiness
, vol.8
, Issue.4
, pp. 353-366
-
-
Horgan, T.J.1
Gilchrist, M.D.2
-
11
-
-
0041669230
-
Cutting moments and grip forces in meat cutting operations and the effect of knife sharpness
-
McGorry R.W., Dowd P.C., and Dempsey P.G. Cutting moments and grip forces in meat cutting operations and the effect of knife sharpness. Appl Ergon 34 4 (2003) 375-382
-
(2003)
Appl Ergon
, vol.34
, Issue.4
, pp. 375-382
-
-
McGorry, R.W.1
Dowd, P.C.2
Dempsey, P.G.3
-
12
-
-
20444435376
-
A technique for field measurement of knife sharpness
-
McGorry R.W., Dowd P.C., and Dempsey P.G. A technique for field measurement of knife sharpness. Appl Ergon 36 5 (2005) 635-640
-
(2005)
Appl Ergon
, vol.36
, Issue.5
, pp. 635-640
-
-
McGorry, R.W.1
Dowd, P.C.2
Dempsey, P.G.3
-
13
-
-
19644373674
-
The effect of blade finish and blade edge angle on forces used in meat cutting operations
-
McGorry R.W., Dowd P.C., and Dempsey P.G. The effect of blade finish and blade edge angle on forces used in meat cutting operations. Appl Ergon 36 1 (2005) 71-77
-
(2005)
Appl Ergon
, vol.36
, Issue.1
, pp. 71-77
-
-
McGorry, R.W.1
Dowd, P.C.2
Dempsey, P.G.3
-
14
-
-
0033452957
-
Knife and impact cutting of lamb bone
-
King M.J. Knife and impact cutting of lamb bone. Meat Sci 52 1 (1999) 29-38
-
(1999)
Meat Sci
, vol.52
, Issue.1
, pp. 29-38
-
-
King, M.J.1
-
16
-
-
0030798637
-
On the cutting edge: tooth blade sharpness in herbivorous and faunivorous mammals
-
Popowics T.E., and Fortelius M. On the cutting edge: tooth blade sharpness in herbivorous and faunivorous mammals. Ann Zool Fennici 34 (1997) 73-88
-
(1997)
Ann Zool Fennici
, vol.34
, pp. 73-88
-
-
Popowics, T.E.1
Fortelius, M.2
-
17
-
-
18644379859
-
Connecting morphology, function and tooth wear in microchiropterans
-
Evans A.R. Connecting morphology, function and tooth wear in microchiropterans. Biol J Linnean Soc 85 1 (2005) 81-96
-
(2005)
Biol J Linnean Soc
, vol.85
, Issue.1
, pp. 81-96
-
-
Evans, A.R.1
-
18
-
-
0030395636
-
Effect of diamond tool sharpness on minimum cutting thickness and cutting surface integrity in ultraprecision machining
-
Yuan J.J., Zhou M., and Dong S. Effect of diamond tool sharpness on minimum cutting thickness and cutting surface integrity in ultraprecision machining. J Mater Process Tech 62 4 (1996) 327-330
-
(1996)
J Mater Process Tech
, vol.62
, Issue.4
, pp. 327-330
-
-
Yuan, J.J.1
Zhou, M.2
Dong, S.3
-
19
-
-
0021911341
-
Measurement of scalpel blade sharpness and its relationship to wound healing
-
Black D., Marks R., and Caunt A. Measurement of scalpel blade sharpness and its relationship to wound healing. Bioengng Skin 1 (1985) 111-123
-
(1985)
Bioengng Skin
, vol.1
, pp. 111-123
-
-
Black, D.1
Marks, R.2
Caunt, A.3
-
20
-
-
0024376019
-
Evaluation of the healing of skin wounds inflicted by steel scalpels with various levels of sharpness
-
Izmailov G.A., Orenburov P.I., Repin V.A., Gorbunov S.M., and Ismailov S.G. Evaluation of the healing of skin wounds inflicted by steel scalpels with various levels of sharpness. Khirurgiia (Mosk) 6 (1989) 75-78
-
(1989)
Khirurgiia (Mosk)
, vol.6
, pp. 75-78
-
-
Izmailov, G.A.1
Orenburov, P.I.2
Repin, V.A.3
Gorbunov, S.M.4
Ismailov, S.G.5
-
21
-
-
0024208470
-
Influence of cutting edge configuration on surgical needle penetration forces
-
Towler M.A., and Rodeheaver G.T. Influence of cutting edge configuration on surgical needle penetration forces. J Emerg Med 6 6 (1988) 475-481
-
(1988)
J Emerg Med
, vol.6
, Issue.6
, pp. 475-481
-
-
Towler, M.A.1
Rodeheaver, G.T.2
-
22
-
-
0034888339
-
Resistance forces acting on suture needles
-
Frick T.B., Marucci D.D., Cartmill J.A., Martin C.J., and Walsh W.R. Resistance forces acting on suture needles. J Biomech 34 10 (2001) 1335-1340
-
(2001)
J Biomech
, vol.34
, Issue.10
, pp. 1335-1340
-
-
Frick, T.B.1
Marucci, D.D.2
Cartmill, J.A.3
Martin, C.J.4
Walsh, W.R.5
-
23
-
-
85007455855
-
Measuring grasping and cutting forces for reality-based haptic modeling
-
Tholey G., Chanthasopeephan T., Hu T., Desai J.P., and Lau A. Measuring grasping and cutting forces for reality-based haptic modeling. Int Congress Series 1256 (2003) 794-800
-
(2003)
Int Congress Series
, vol.1256
, pp. 794-800
-
-
Tholey, G.1
Chanthasopeephan, T.2
Hu, T.3
Desai, J.P.4
Lau, A.5
-
24
-
-
0029664634
-
Cutting force measurement platform for quantitative assessment of surgical cutting instruments
-
Santhanam R., and Valenta H.L. Cutting force measurement platform for quantitative assessment of surgical cutting instruments. Biomed Sci Instrum 32 (1996) 237-243
-
(1996)
Biomed Sci Instrum
, vol.32
, pp. 237-243
-
-
Santhanam, R.1
Valenta, H.L.2
-
25
-
-
10044292274
-
The effect of knife geometry on cutting force and fracture in sugar beet topping
-
Moore M.A., King F.S., Davis P.F., and Manby T.C.D. The effect of knife geometry on cutting force and fracture in sugar beet topping. J Agr Engng Res 24 1 (1979) 11-27
-
(1979)
J Agr Engng Res
, vol.24
, Issue.1
, pp. 11-27
-
-
Moore, M.A.1
King, F.S.2
Davis, P.F.3
Manby, T.C.D.4
-
26
-
-
0032689938
-
Role of blade sharpness in cutting instabilities of polyethylene terephthalate
-
Meehan R.R., Kumar J., Earl M., Svenson E., and Burns S.J. Role of blade sharpness in cutting instabilities of polyethylene terephthalate. J Mat Sci Lett 18 2 (1999) 93-95
-
(1999)
J Mat Sci Lett
, vol.18
, Issue.2
, pp. 93-95
-
-
Meehan, R.R.1
Kumar, J.2
Earl, M.3
Svenson, E.4
Burns, S.J.5
-
29
-
-
34047200952
-
-
ISO International Standard Materials and articles in contact with foodstuff - Cutlery and table hollowware. Part 5: Specification for sharpness and edge retention test of cutlery. ISO 8442-5:2004(E), 2004.
-
-
-
-
30
-
-
0018021089
-
Measurement of rubber cutting resistance in the absence of friction
-
Lake G.J., and Yeoh O.H. Measurement of rubber cutting resistance in the absence of friction. Int J Fract 14 5 (1978) 509-526
-
(1978)
Int J Fract
, vol.14
, Issue.5
, pp. 509-526
-
-
Lake, G.J.1
Yeoh, O.H.2
-
31
-
-
31744444709
-
A numerical and experimental investigation into the forces generated when cutting biomaterials
-
Helmus M., and Medlin D. (Eds), ASM International
-
McCarthy C.T., O'Dwyer E., Hussey M., Gilchrist M.D., and O'Dowd N.P. A numerical and experimental investigation into the forces generated when cutting biomaterials. In: Helmus M., and Medlin D. (Eds). Medical device materials II. Proceedings of the materials and processes for medical devices conference, August 25-27, 2004, St. Paul, MN, USA (2005), ASM International 140-145
-
(2005)
Medical device materials II. Proceedings of the materials and processes for medical devices conference, August 25-27, 2004, St. Paul, MN, USA
, pp. 140-145
-
-
McCarthy, C.T.1
O'Dwyer, E.2
Hussey, M.3
Gilchrist, M.D.4
O'Dowd, N.P.5
-
32
-
-
0001737632
-
Large deformation isotropic elasticity: on the correlation of theory and experiment for incompressible rubberlike solids
-
Ogden R.W. Large deformation isotropic elasticity: on the correlation of theory and experiment for incompressible rubberlike solids. Proc R Soc Lond A 326 (1972) 565-584
-
(1972)
Proc R Soc Lond A
, vol.326
, pp. 565-584
-
-
Ogden, R.W.1
-
33
-
-
10244261513
-
A simplified model to determine the contribution of strain energy in the failure process of thin biological membranes during cutting
-
Doran C.F., McCormack B.A.O., and Macey A. A simplified model to determine the contribution of strain energy in the failure process of thin biological membranes during cutting. Strain 40 4 (2004) 173-179
-
(2004)
Strain
, vol.40
, Issue.4
, pp. 173-179
-
-
Doran, C.F.1
McCormack, B.A.O.2
Macey, A.3
-
34
-
-
0031059931
-
Ranking the fracture toughness of thin mammalian soft tissues using the scissors cutting test
-
Pereira B.P., Lucas P.W., and Swee-Hin T. Ranking the fracture toughness of thin mammalian soft tissues using the scissors cutting test. J Biomech 30 1 (1997) 91-94
-
(1997)
J Biomech
, vol.30
, Issue.1
, pp. 91-94
-
-
Pereira, B.P.1
Lucas, P.W.2
Swee-Hin, T.3
-
35
-
-
11044233592
-
Toughness and cutting: a new way of simultaneously determining ductile fracture toughness and strength
-
Atkins A.G. Toughness and cutting: a new way of simultaneously determining ductile fracture toughness and strength. Engng Fract Mech 72 6 (2005) 849-860
-
(2005)
Engng Fract Mech
, vol.72
, Issue.6
, pp. 849-860
-
-
Atkins, A.G.1
-
36
-
-
17444376475
-
Cutting forces in food: experimental measurements
-
Brown T., James S.T., and Purnell G.L. Cutting forces in food: experimental measurements. J Food Engng 70 2 (2005) 165-170
-
(2005)
J Food Engng
, vol.70
, Issue.2
, pp. 165-170
-
-
Brown, T.1
James, S.T.2
Purnell, G.L.3
-
37
-
-
0030919167
-
Silicone manufacturing for long-term implants
-
Compton R.A. Silicone manufacturing for long-term implants. J Long-term Eff Med Imp 7 1 (1997) 29-54
-
(1997)
J Long-term Eff Med Imp
, vol.7
, Issue.1
, pp. 29-54
-
-
Compton, R.A.1
-
38
-
-
17144364006
-
Mechanisms of deep penetration of soft solids, with application to the injection and wounding of skin
-
Shergold O.A., and Fleck N.A. Mechanisms of deep penetration of soft solids, with application to the injection and wounding of skin. Proc R Soc Lond A 460 (2004) 3037-3058
-
(2004)
Proc R Soc Lond A
, vol.460
, pp. 3037-3058
-
-
Shergold, O.A.1
Fleck, N.A.2
-
40
-
-
34047193584
-
-
O'Dwyer E, Experimental cutting of surrogate soft biological tissue with unserrated blades, M.Eng.Sc. thesis, University College Dublin, 2005.
-
-
-
-
41
-
-
34047211004
-
-
McCarthy C, Hussey M, Gilchrist MD, On the sharpness of straight edge blades in cutting soft solids: Part II: Analysis of blade geometry, in preparation.
-
-
-
|