메뉴 건너뛰기




Volumn 31, Issue 3, 2007, Pages 128-140

From MIP image to MRA segmentation using fuzzy set theory

Author keywords

3D segmentation; Fuzzy logic; Maximum intensity projection; MR angiography

Indexed keywords

BIOLOGICAL ORGANS; FUZZY LOGIC; FUZZY SETS; IMAGE ANALYSIS; MEDICAL IMAGING;

EID: 33947717793     PISSN: 08956111     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.compmedimag.2006.12.002     Document Type: Article
Times cited : (23)

References (20)
  • 1
    • 0035469971 scopus 로고    scopus 로고
    • Acquisition, segmentation and tracking of the cerebral vascular tree on 3D magnetic resonance angiography images
    • Flasque N., Desvignes M., Constans J.M., and Revenu M. Acquisition, segmentation and tracking of the cerebral vascular tree on 3D magnetic resonance angiography images. Med Image Anal 5 (2001) 173-183
    • (2001) Med Image Anal , vol.5 , pp. 173-183
    • Flasque, N.1    Desvignes, M.2    Constans, J.M.3    Revenu, M.4
  • 3
    • 31744435697 scopus 로고    scopus 로고
    • Magnetic resonance angiography: from anatomical knowledge modelling to vessel segmentation
    • Passat N., Ronse C., Baruthi J., Armspach J.P., and Maillot C. Magnetic resonance angiography: from anatomical knowledge modelling to vessel segmentation. Med Image Anal 10 (2006) 259-274
    • (2006) Med Image Anal , vol.10 , pp. 259-274
    • Passat, N.1    Ronse, C.2    Baruthi, J.3    Armspach, J.P.4    Maillot, C.5
  • 4
    • 1642503005 scopus 로고    scopus 로고
    • 3D volume segmentation of MRA data sets using level sets
    • Farag A.A., Hassan H., Falk R., and Hushek S.G. 3D volume segmentation of MRA data sets using level sets. Acad Radiol 11 (2004) 419-435
    • (2004) Acad Radiol , vol.11 , pp. 419-435
    • Farag, A.A.1    Hassan, H.2    Falk, R.3    Hushek, S.G.4
  • 6
    • 0033201370 scopus 로고    scopus 로고
    • An adaptive segmentation algorithm for time of flight MRA data
    • Wilson D.L., and Noble J.A. An adaptive segmentation algorithm for time of flight MRA data. IEEE Trans Med Imag 18 (1999) 938-945
    • (1999) IEEE Trans Med Imag , vol.18 , pp. 938-945
    • Wilson, D.L.1    Noble, J.A.2
  • 7
    • 0036462551 scopus 로고    scopus 로고
    • Initialization, noise, singularities, and scale in height ridge traversal for tubular object centerline extraction
    • Aylward S.R., and Bullit E. Initialization, noise, singularities, and scale in height ridge traversal for tubular object centerline extraction. IEEE Trans Med Imag 21 (2002) 61-75
    • (2002) IEEE Trans Med Imag , vol.21 , pp. 61-75
    • Aylward, S.R.1    Bullit, E.2
  • 8
    • 49349133217 scopus 로고
    • Fuzzy sets as a basis for a theory of possibility
    • Zadeh L.A. Fuzzy sets as a basis for a theory of possibility. Fuzzy Sets Syst 1 (1978) 3-28
    • (1978) Fuzzy Sets Syst , vol.1 , pp. 3-28
    • Zadeh, L.A.1
  • 10
    • 25644444050 scopus 로고    scopus 로고
    • Statistical cerebrovascular segmentation in three-dimensional rotational angiography based on maximum intensity projections
    • Gan R., Wong W.C.K., and Chung A.C.S. Statistical cerebrovascular segmentation in three-dimensional rotational angiography based on maximum intensity projections. Med Phys 32 (2005) 3017-3028
    • (2005) Med Phys , vol.32 , pp. 3017-3028
    • Gan, R.1    Wong, W.C.K.2    Chung, A.C.S.3
  • 11
    • 1842431666 scopus 로고    scopus 로고
    • Intracranial vessel segmentation from TOF MRA using preprocessing of the MIP Z-Buffer: accuracy of the ZBS algorithm
    • Chapman B.E., Stapelton J.O., and Parker D.L. Intracranial vessel segmentation from TOF MRA using preprocessing of the MIP Z-Buffer: accuracy of the ZBS algorithm. Med Image Anal 8 (2004) 113-126
    • (2004) Med Image Anal , vol.8 , pp. 113-126
    • Chapman, B.E.1    Stapelton, J.O.2    Parker, D.L.3
  • 12
    • 0025032564 scopus 로고
    • Displays for MR angiography
    • Laub G. Displays for MR angiography. Magn Reson Med 14 (1990) 222-229
    • (1990) Magn Reson Med , vol.14 , pp. 222-229
    • Laub, G.1
  • 13
    • 0035544621 scopus 로고    scopus 로고
    • Volume delineation by fusion of fuzzy sets obtained from multiplanar tomographic images
    • Vial S., Gibon D., Vasseur C., and Rousseau J. Volume delineation by fusion of fuzzy sets obtained from multiplanar tomographic images. IEEE Trans Med Imag 20 (2001) 1362-1372
    • (2001) IEEE Trans Med Imag , vol.20 , pp. 1362-1372
    • Vial, S.1    Gibon, D.2    Vasseur, C.3    Rousseau, J.4
  • 14
    • 0029756565 scopus 로고    scopus 로고
    • Information combination operator for data fusion: a comparative review with classification
    • Bloch I. Information combination operator for data fusion: a comparative review with classification. IEEE Trans Syst Man Cybern 26 (1996) 52-67
    • (1996) IEEE Trans Syst Man Cybern , vol.26 , pp. 52-67
    • Bloch, I.1
  • 15
    • 0001967103 scopus 로고
    • Combination of fuzzy information in the framework of possibility theory
    • Abidi M.A., and Gonzalez R.C. (Eds), Academic Press, New York
    • Dubois D., and Prade H. Combination of fuzzy information in the framework of possibility theory. In: Abidi M.A., and Gonzalez R.C. (Eds). Data Fusion in Robotics and Machine Intelligence (1992), Academic Press, New York 481-505
    • (1992) Data Fusion in Robotics and Machine Intelligence , pp. 481-505
    • Dubois, D.1    Prade, H.2
  • 16
    • 0033430135 scopus 로고    scopus 로고
    • Automatic quality assessment protocol for MRI equipment
    • Bourel P., Gibon D., Coste E., Daanen V., and Rousseau J. Automatic quality assessment protocol for MRI equipment. Med Phys 26 (1999) 2693-2700
    • (1999) Med Phys , vol.26 , pp. 2693-2700
    • Bourel, P.1    Gibon, D.2    Coste, E.3    Daanen, V.4    Rousseau, J.5
  • 18
    • 33947731147 scopus 로고    scopus 로고
    • Yushkevich PA, Piven J, Cody H, Ho S, Gee JC, Gerig G. User-guided level set segmentation of anatomical structures with ITK-SNAP. Insight journal special issue on ISC/NA-MIC/MICCAI workshop on open-source software, 2005.
  • 19
    • 33947713280 scopus 로고    scopus 로고
    • 3D reconstruction of the encapsulating contour of arteriovenous malformations for radiosurgery using digital subtraction angiography
    • Coste E., Gibon D., Leclerc X., Verdonck B., Vasseur C., and Rousseau J. 3D reconstruction of the encapsulating contour of arteriovenous malformations for radiosurgery using digital subtraction angiography. Int J Rad Oncol Biol Phys 50 (2001) 255-263
    • (2001) Int J Rad Oncol Biol Phys , vol.50 , pp. 255-263
    • Coste, E.1    Gibon, D.2    Leclerc, X.3    Verdonck, B.4    Vasseur, C.5    Rousseau, J.6
  • 20
    • 0035384138 scopus 로고    scopus 로고
    • Symbolic description of intracerebral vessels segmented from magnetic resonance angiograms and evaluation by comparison with X-ray angiograms
    • Bullit E., Aylward S., Smith K., Mukherji S., Jiroutek M., and Muller K. Symbolic description of intracerebral vessels segmented from magnetic resonance angiograms and evaluation by comparison with X-ray angiograms. Med Image Anal 5 (2001) 157-169
    • (2001) Med Image Anal , vol.5 , pp. 157-169
    • Bullit, E.1    Aylward, S.2    Smith, K.3    Mukherji, S.4    Jiroutek, M.5    Muller, K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.