메뉴 건너뛰기




Volumn 5, Issue 3, 2001, Pages 173-183

Acquisition, segmentation and tracking of the cerebral vascular tree on 3D magnetic resonance angiography images

Author keywords

Cerebral vascular tree; Magnetic resonance angiography

Indexed keywords

ALGORITHM; ARTICLE; CEREBRAL ARTERY DISEASE; CEREBROVASCULAR DISEASE; CONTRAST ENHANCEMENT; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIGITAL SUBTRACTION ANGIOGRAPHY; HUMAN; IMAGE ANALYSIS; IMAGE PROCESSING; IMAGE QUALITY; IMAGE RECONSTRUCTION; MAGNETIC RESONANCE ANGIOGRAPHY; OCCLUSIVE CEREBROVASCULAR DISEASE; PRIORITY JOURNAL; THREE DIMENSIONAL IMAGING; VASCULARIZATION;

EID: 0035469971     PISSN: 13618415     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1361-8415(01)00038-X     Document Type: Article
Times cited : (85)

References (29)
  • 2
    • 21844522780 scopus 로고
    • 2-D and 3-D motion analysis in digital subtraction angiography
    • Lecture Notes in Computer Science
    • Coatrieux, J.L., Mao, F., Toumoulin, C., Collorec, R., 1995. 2-D and 3-D motion analysis in digital subtraction angiography. In: CVRMed95. Lecture Notes in Computer Science, Vol. 905, pp. 295-304.
    • (1995) CVRMed95 , vol.905 , pp. 295-304
    • Coatrieux, J.L.1    Mao, F.2    Toumoulin, C.3    Collorec, R.4
  • 3
    • 0011244330 scopus 로고    scopus 로고
    • Global minimum for active contours models: A minimal path approach
    • Ceremade TR9612
    • Cohen, L., Kimmel, R., 1996. Global minimum for active contours models: a minimal path approach. Ceremade TR9612.
    • (1996)
    • Cohen, L.1    Kimmel, R.2
  • 4
    • 0011227672 scopus 로고    scopus 로고
    • Vessel enhancement filtering in magnetic resonance angiography
    • Du, Y., Parker, D., 1998. Vessel enhancement filtering in magnetic resonance angiography. Magn. Reson. Imaging 16 (2), XII-XIII.
    • (1998) Magn. Reson. Imaging , vol.16 , Issue.2
    • Du, Y.1    Parker, D.2
  • 5
    • 0029270287 scopus 로고
    • A non smoothing approach to the estimation of vessel contours in angiograms
    • Figueiredo, M., Ao, J.L., 1995. A non smoothing approach to the estimation of vessel contours in angiograms. IEEE Trans. Med. Imaging 14, 162-172.
    • (1995) IEEE Trans. Med. Imaging , vol.14 , pp. 162-172
    • Figueiredo, M.1    Ao, J.L.2
  • 6
    • 0033201371 scopus 로고    scopus 로고
    • Model based quantification of 3D magnetic resonance angiographic images
    • Frangi, A., Niessen, W.J., Hoogeven, R.M., Viergever, M., 1999. Model based quantification of 3D magnetic resonance angiographic images. IEEE Trans. Med. Imaging 18 (10), 946-956.
    • (1999) IEEE Trans. Med. Imaging , vol.18 , Issue.10 , pp. 946-956
    • Frangi, A.1    Niessen, W.J.2    Hoogeven, R.M.3    Viergever, M.4
  • 7
    • 0002854447 scopus 로고
    • Symbolic description of 3-D structures applied to cerebral vessel tree obtained from MR angiography volume data
    • Lecture Notes in Computer Science
    • Gerig, G., Koller, T., Szókely, G., Brechbühler, C., Kübler, O., 1993. Symbolic description of 3-D structures applied to cerebral vessel tree obtained from MR angiography volume data. In: Information Processing in Medical Imaging (IPMI'93). Lecture Notes in Computer Science, Vol. 687, pp. 94-111.
    • (1993) Information Processing in Medical Imaging (IPMI'93) , vol.687 , pp. 94-111
    • Gerig, G.1    Koller, T.2    Szókely, G.3    Brechbühler, C.4    Kübler, O.5
  • 10
    • 0031784731 scopus 로고    scopus 로고
    • Limits to the accuracy of vessel diameter measurement in MR angiography
    • Hoogeveen, R., Bakker, C., Viergever, M., 1998. Limits to the accuracy of vessel diameter measurement in MR angiography. JMRI 8 (6), 1228-1239.
    • (1998) JMRI , vol.8 , Issue.6 , pp. 1228-1239
    • Hoogeveen, R.1    Bakker, C.2    Viergever, M.3
  • 12
    • 0028859039 scopus 로고
    • Tracking of cerebral vessels in MR angiography after highpass filtering
    • Klose, U., Petersen, D., Martos, T.J., 1995. Tracking of cerebral vessels in MR angiography after highpass filtering. Magn. Reson. Imaging 13 (1), 45-51.
    • (1995) Magn. Reson. Imaging , vol.13 , Issue.1 , pp. 45-51
    • Klose, U.1    Petersen, D.2    Martos, T.J.3
  • 15
    • 0030081840 scopus 로고    scopus 로고
    • Extraction of line properties based on direction fields
    • Kutka, R., Stier, S., 1996. Extraction of line properties based on direction fields. IEEE Trans. Med. Imaging 15 (1), 51-58.
    • (1996) IEEE Trans. Med. Imaging , vol.15 , Issue.1 , pp. 51-58
    • Kutka, R.1    Stier, S.2
  • 16
    • 85177199074 scopus 로고
    • Simultaneous tracking of the two edges of linear structures
    • 1st ICIP, Austin, TX
    • Lecornu, L., Jacq, J.J., Roux, C., 1994. Simultaneous tracking of the two edges of linear structures. In: 1st ICIP, Austin, TX, pp. 158-161.
    • (1994) , pp. 158-161
    • Lecornu, L.1    Jacq, J.J.2    Roux, C.3
  • 17
    • 0001055713 scopus 로고    scopus 로고
    • Multi-scale line segmentation with automatic estimation of width, contrast ant tangential direction in 2D and 3D medical images
    • 1205 Lecture Notes in Computer Science
    • Lorenz, C., Carsen, I.-C., Buzug, T., Fassnacht, C., Weese, J., 1997. Multi-scale line segmentation with automatic estimation of width, contrast ant tangential direction in 2D and 3D medical images. In: CVRMed-MRCAS'97. Lecture Notes in Computer Science, Vol. 1205, pp. 213-222.
    • (1997) CVRMed-MRCAS'97 , pp. 213-222
    • Lorenz, C.1    Carsen, I.-C.2    Buzug, T.3    Fassnacht, C.4    Weese, J.5
  • 18
    • 0011182143 scopus 로고    scopus 로고
    • Anisotropic non-linear filtering for image improvement in MR angiography
    • International Compress Series, 1224
    • Orkisz, M., Douek, R, Magnin, I., 1996. Anisotropic non-linear filtering for image improvement in MR angiography. In: Computer Assisted Radiology. International Compress Series, Vol. 1224, pp. 322-328.
    • (1996) Computer Assisted Radiology , pp. 322-328
    • Orkisz, M.1    Douek, R.2    Magnin, I.3
  • 19
    • 0025465145 scopus 로고
    • Scale-space and edge detection using anisotropic diffusion
    • Perona, P., Malik, J., 1990. Scale-space and edge detection using anisotropic diffusion. IEEE Trans. Patt. Anal. Mach. Intell. 12 (7), 629-639.
    • (1990) IEEE Trans. Patt. Anal. Mach. Intell , vol.12 , Issue.7 , pp. 629-639
    • Perona, P.1    Malik, J.2
  • 20
    • 4243396499 scopus 로고    scopus 로고
    • Efficient enhancement and segmentation of blood vessels by integration of multiple directional filters
    • Technical Report #940701, Department of Electronic Engineering, University of Florence
    • Poli, R., Valli, G., 1998. Efficient enhancement and segmentation of blood vessels by integration of multiple directional filters. Technical Report #940701, Department of Electronic Engineering, University of Florence.
    • (1998)
    • Poli, R.1    Valli, G.2
  • 21
    • 84974755199 scopus 로고
    • A 3-D moment based approach for blood vessel detection and quantification in MRA
    • Reuzé, P., Coatrieux, J.L., Luo, L.M., Dillenseger, J.L., 1993. A 3-D moment based approach for blood vessel detection and quantification in MRA. Technol. Health Care 1, 181-188.
    • (1993) Technol. Health Care , vol.1 , pp. 181-188
    • Reuzé, P.1    Coatrieux, J.L.2    Luo, L.M.3    Dillenseger, J.L.4
  • 22
    • 0032081365 scopus 로고    scopus 로고
    • Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images
    • Sato, Y., Nakajima, S., Shiraga, N., Atsumi, H., Yoshida, S., Koller, T., Gerig, G., Kikinis, R., 1998. Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images. Medical Image Analysis 2 (2), 143-168.
    • (1998) Medical Image Analysis , vol.2 , Issue.2 , pp. 143-168
    • Sato, Y.1    Nakajima, S.2    Shiraga, N.3    Atsumi, H.4    Yoshida, S.5    Koller, T.6    Gerig, G.7    Kikinis, R.8
  • 24
    • 0031397862 scopus 로고    scopus 로고
    • Multiresolution, model based segmentation of MR angiograms
    • Summers, P., Bhalerao, A.H., Hawkes, D.J., 1997. Multiresolution, model based segmentation of MR angiograms. J. Magn. Reson. 7 (6), 950-957.
    • (1997) J. Magn. Reson , vol.7 , Issue.6 , pp. 950-957
    • Summers, P.1    Bhalerao, A.H.2    Hawkes, D.J.3
  • 25
    • 0029322515 scopus 로고
    • Directional low-pass filtering for improved accuracy and reproducibility of stenosis quantification in coronary angiograms
    • Sun, Y., Lucariello, R.J., Chiaramida, S.A., 1995. Directional low-pass filtering for improved accuracy and reproducibility of stenosis quantification in coronary angiograms. IEEE Trans. Med. Imaging 14, 242-248.
    • (1995) IEEE Trans. Med. Imaging , vol.14 , pp. 242-248
    • Sun, Y.1    Lucariello, R.J.2    Chiaramida, S.A.3
  • 26
    • 0011223903 scopus 로고
    • A new system for blood vessel segmentation and visualization in 3D MR and spiral CT angiography
    • Verdonck, B., Bloch, I., Maitre, H., Vandermeulen, D., Marchal, G., 1995. A new system for blood vessel segmentation and visualization in 3D MR and spiral CT angiography. Comput. Assisted Radiol., 177-182.
    • (1995) Comput. Assisted Radiol , pp. 177-182
    • Verdonck, B.1    Bloch, I.2    Maitre, H.3    Vandermeulen, D.4    Marchal, G.5
  • 29
    • 0033201370 scopus 로고    scopus 로고
    • An adaptative segmentation algorithm for time-of-flight MRA data
    • Wilson, D.L., Noble, J.A., 1999. An adaptative segmentation algorithm for time-of-flight MRA data. IEEE Trans. Med. Imaging 18 (10), 938-945.
    • (1999) IEEE Trans. Med. Imaging , vol.18 , Issue.10 , pp. 938-945
    • Wilson, D.L.1    Noble, J.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.