메뉴 건너뛰기




Volumn 262, Issue 9-10, 2007, Pages 1171-1181

Isolation, characterization and quantification of polyethylene wear debris from periprosthetic tissues around total joint replacements

Author keywords

Arthroplasty; Isolation of wear debris; Quantification of wear particles; SEM; Total joint replacements; UHMWPE

Indexed keywords

CHEMICAL ANALYSIS; ENERGY DISPERSIVE SPECTROSCOPY; POLYETHYLENES; SCANNING ELECTRON MICROSCOPY; TISSUE;

EID: 33947628250     PISSN: 00431648     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.wear.2006.11.005     Document Type: Article
Times cited : (34)

References (24)
  • 3
    • 0003912158 scopus 로고    scopus 로고
    • Wright T.M., and Goodman S.B. (Eds), American Academy of Orthopaedic Surgeons, Illinois, USA pp. 5 and 8
    • In: Wright T.M., and Goodman S.B. (Eds). Implant Wear in Total Joint Replacement (2001), American Academy of Orthopaedic Surgeons, Illinois, USA pp. 5 and 8
    • (2001) Implant Wear in Total Joint Replacement
  • 6
    • 0028076951 scopus 로고
    • Isolation and characterization of debris in membranes around total joint prostheses
    • Margevicius K.J., Bauer T.W., McMahon J.T., Brown S.A., and Merritt K. Isolation and characterization of debris in membranes around total joint prostheses. J. Bone Joint Surg. 76-A (1994) 1664-1675
    • (1994) J. Bone Joint Surg. , vol.76 -A , pp. 1664-1675
    • Margevicius, K.J.1    Bauer, T.W.2    McMahon, J.T.3    Brown, S.A.4    Merritt, K.5
  • 7
    • 0035482379 scopus 로고    scopus 로고
    • Do current wear particle isolation procedures underestimate the number of particles generated by prosthetic bearing components?
    • Scott M., Widding K., and Jani S. Do current wear particle isolation procedures underestimate the number of particles generated by prosthetic bearing components?. Wear 251 (2001) 1213-1217
    • (2001) Wear , vol.251 , pp. 1213-1217
    • Scott, M.1    Widding, K.2    Jani, S.3
  • 10
    • 0036023691 scopus 로고    scopus 로고
    • Quantitative analysis of UHMWPE wear debris isolated from the periprosthetic femoral tissues from a series of Charnley total hip arthoplasties
    • Bell J., Tipper J.L., Ingham E., Stone M.H., Wroblewski B.M., and Fisher J. Quantitative analysis of UHMWPE wear debris isolated from the periprosthetic femoral tissues from a series of Charnley total hip arthoplasties. Biomed. Mater. Eng. 12 (2002) 198-201
    • (2002) Biomed. Mater. Eng. , vol.12 , pp. 198-201
    • Bell, J.1    Tipper, J.L.2    Ingham, E.3    Stone, M.H.4    Wroblewski, B.M.5    Fisher, J.6
  • 12
    • 0029147350 scopus 로고
    • Isolation and characterization of wear particles generated in patients who have had failure of a hip arthroplasty without cement
    • Maloney W.J., Smith R.L., Schmalzried T.P., Chiba J., Huene D., and Rubash H. Isolation and characterization of wear particles generated in patients who have had failure of a hip arthroplasty without cement. J. Bone Joint Surg. 77-A (1995) 1301-1310
    • (1995) J. Bone Joint Surg. , vol.77 -A , pp. 1301-1310
    • Maloney, W.J.1    Smith, R.L.2    Schmalzried, T.P.3    Chiba, J.4    Huene, D.5    Rubash, H.6
  • 13
    • 0345168808 scopus 로고    scopus 로고
    • The nature and dissemination of UHMWPE wear debris retrieved from periprosthetic tissue of THR
    • Elfick A.P.D., Green S.M., Krikler S., and Unsworth A. The nature and dissemination of UHMWPE wear debris retrieved from periprosthetic tissue of THR. J. Biomed. Mater. Res. 65A (2003) 95-108
    • (2003) J. Biomed. Mater. Res. , vol.65 A , pp. 95-108
    • Elfick, A.P.D.1    Green, S.M.2    Krikler, S.3    Unsworth, A.4
  • 14
    • 0031912659 scopus 로고    scopus 로고
    • Quantitative comparison of wear debris from UHMWPE that has and has not been sterilised by gamma irradiation
    • Besong A.A., Tipper J.L., Ingham E., Stone M.H., Wroblewski B.M., and Fisher J. Quantitative comparison of wear debris from UHMWPE that has and has not been sterilised by gamma irradiation. J. Bone Joint Surg. 80B (1998) 340-344
    • (1998) J. Bone Joint Surg. , vol.80 B , pp. 340-344
    • Besong, A.A.1    Tipper, J.L.2    Ingham, E.3    Stone, M.H.4    Wroblewski, B.M.5    Fisher, J.6
  • 15
    • 0029839935 scopus 로고    scopus 로고
    • Characterisation and comparison of wear debris from failed total hip implants of different types
    • Hirakawa K., Bauer T.W., Stulberg B.N., Wilde A.H., and Secic M. Characterisation and comparison of wear debris from failed total hip implants of different types. J. Bone Joint Surg. 78A (1996) 1235-1243
    • (1996) J. Bone Joint Surg. , vol.78 A , pp. 1235-1243
    • Hirakawa, K.1    Bauer, T.W.2    Stulberg, B.N.3    Wilde, A.H.4    Secic, M.5
  • 18
    • 0029748331 scopus 로고    scopus 로고
    • Wear and morphology of ultra-high molecular weight polyethylene wear particles from total hip replacements
    • Campbell P., Doorn P., Dorey F., and Amstutz H.C. Wear and morphology of ultra-high molecular weight polyethylene wear particles from total hip replacements. Proc. Inst. Mech. Eng. Part H 210 (1996) 167-174
    • (1996) Proc. Inst. Mech. Eng. Part H , vol.210 , pp. 167-174
    • Campbell, P.1    Doorn, P.2    Dorey, F.3    Amstutz, H.C.4
  • 19
    • 0030175572 scopus 로고    scopus 로고
    • Comparison and quantification of wear debris of failed total hip and knee arthroplasty
    • Hirakawa K., Bauer T.W., Stulberg B.N., and Wilde A.H. Comparison and quantification of wear debris of failed total hip and knee arthroplasty. J. Biomed. Mater. Res. 31 (1996) 257-263
    • (1996) J. Biomed. Mater. Res. , vol.31 , pp. 257-263
    • Hirakawa, K.1    Bauer, T.W.2    Stulberg, B.N.3    Wilde, A.H.4
  • 22
    • 21044443759 scopus 로고    scopus 로고
    • Analysis of polyethylene particles isolated from periprosthetic tissue of loosened hip arthroplasty and comparison with radiographic appearance
    • Koseki H., Matsumoto T., Ito S., and Doukawa H. Analysis of polyethylene particles isolated from periprosthetic tissue of loosened hip arthroplasty and comparison with radiographic appearance. J. Orthop. Sci. 10 (2005) 284-290
    • (2005) J. Orthop. Sci. , vol.10 , pp. 284-290
    • Koseki, H.1    Matsumoto, T.2    Ito, S.3    Doukawa, H.4
  • 23
    • 33947626629 scopus 로고    scopus 로고
    • Comparison of the wear, wear debris and functional biological activity of non-crosslinked and crosslinked GUR 1020 and GUR 1050 polyethylenes used in total hip prostheses
    • Costa L., Brach del Prever E.M., and Bracco P. (Eds), Litografia MG snc, Torino, Italy
    • Tipper J.L., Galvin A.L., Ingham E., and Fisher J. Comparison of the wear, wear debris and functional biological activity of non-crosslinked and crosslinked GUR 1020 and GUR 1050 polyethylenes used in total hip prostheses. In: Costa L., Brach del Prever E.M., and Bracco P. (Eds). UHMWPE for Arthroplasty: from Synthesis to Implant (2005), Litografia MG snc, Torino, Italy 107-120
    • (2005) UHMWPE for Arthroplasty: from Synthesis to Implant , pp. 107-120
    • Tipper, J.L.1    Galvin, A.L.2    Ingham, E.3    Fisher, J.4
  • 24
    • 33646387152 scopus 로고    scopus 로고
    • Bio-ferrography to capture and separate polyethylene wear debris from hip simulator fluid and compared with conventional filter method
    • Meyer D.M., Tillinghast A., Hanumara N.C., and Franco A. Bio-ferrography to capture and separate polyethylene wear debris from hip simulator fluid and compared with conventional filter method. J. Tribol.: Trans. ASME 128 (2006) 436-441
    • (2006) J. Tribol.: Trans. ASME , vol.128 , pp. 436-441
    • Meyer, D.M.1    Tillinghast, A.2    Hanumara, N.C.3    Franco, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.