Volumn 65, Issue 4, 2007, Pages 285-291

Humidification policies for mechanically ventilated intensive care patients and prevention of ventilator-associated pneumonia: a systematic review of randomized controlled trials

Author keywords

Humidification method; Systematic review; Ventilator associated pneumonia

Indexed keywords

ARTIFICIAL VENTILATION; CLINICAL TRIAL; COCHRANE LIBRARY; DATA EXTRACTION; HUMAN; HUMIDIFIER; INFECTION RISK; INFORMATION RETRIEVAL; INTENSIVE CARE; MEDLINE; META ANALYSIS; MICROBIAL COLONIZATION; POLICY; PUBLICATION; REVIEW; RISK ASSESSMENT; SYSTEMATIC REVIEW; VENTILATOR ASSOCIATED PNEUMONIA;

EID: 33947578746     PISSN: 01956701     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jhin.2006.10.020     Document Type: Review
Times cited : (21)

References (14)
  • 1
    • 0021275019 scopus 로고
    • Contaminated condensate in mechanical ventilator circuits: a risk for nosocomial pneumonia?
    • Craven D.E., Goularte T.A., and Make B.J. Contaminated condensate in mechanical ventilator circuits: a risk for nosocomial pneumonia?. Am Rev Respir Dis 129 (1984) 625-628
    • (1984) Am Rev Respir Dis , vol.129 , pp. 625-628
    • Craven, D.E.1    Goularte, T.A.2    Make, B.J.3
  • 2
    • 12944296648 scopus 로고    scopus 로고
    • Efficacy of heat and moisture exchangers in preventing ventilator-associated pneumonia: meta-anaysis of randomized controlled trials
    • Kola A., Eckmans T., and Gastmeier P. Efficacy of heat and moisture exchangers in preventing ventilator-associated pneumonia: meta-anaysis of randomized controlled trials. Intensive Care Med 31 (2005) 5-11
    • (2005) Intensive Care Med , vol.31 , pp. 5-11
    • Kola, A.1    Eckmans, T.2    Gastmeier, P.3
  • 3
    • 0034797673 scopus 로고    scopus 로고
    • A randomized clinical trial to compare the effects of a heat and moisture exchanger with a heated humidifying system on the occurrence rate of ventilator-associated pneumonia
    • Memish Z.A., Oni G.A., Djazmati W., Cunningham G., and Mah M.W. A randomized clinical trial to compare the effects of a heat and moisture exchanger with a heated humidifying system on the occurrence rate of ventilator-associated pneumonia. Am J Infect Control 29 (2001) 301-305
    • (2001) Am J Infect Control , vol.29 , pp. 301-305
    • Memish, Z.A.1    Oni, G.A.2    Djazmati, W.3    Cunningham, G.4    Mah, M.W.5
  • 4
    • 0030874818 scopus 로고    scopus 로고
    • Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients
    • Boots R.J., Howe S., George N., Harris F.M., and Faoagali J. Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients. Crit Care Med 25 (1997) 1707-1712
    • (1997) Crit Care Med , vol.25 , pp. 1707-1712
    • Boots, R.J.1    Howe, S.2    George, N.3    Harris, F.M.4    Faoagali, J.5
  • 5
    • 33644604269 scopus 로고    scopus 로고
    • Double-heater-wire circuits and heat-and-moisture exchangers and the risk of ventilator-associated pneumonia
    • Boots R.J., George N., Faoagali J.L., Druery J., Dean K., and Heller R.F. Double-heater-wire circuits and heat-and-moisture exchangers and the risk of ventilator-associated pneumonia. Crit Care Med 34 (2006) 687-693
    • (2006) Crit Care Med , vol.34 , pp. 687-693
    • Boots, R.J.1    George, N.2    Faoagali, J.L.3    Druery, J.4    Dean, K.5    Heller, R.F.6
  • 6
    • 0029831013 scopus 로고    scopus 로고
    • Comparison of 3 humidification techniques during mechanical ventilation: patient selection, cost, and infection considerations
    • Branson R.D., Davis K., Brown R., and Rashkin M. Comparison of 3 humidification techniques during mechanical ventilation: patient selection, cost, and infection considerations. Respir Care 41 (1996) 809-816
    • (1996) Respir Care , vol.41 , pp. 809-816
    • Branson, R.D.1    Davis, K.2    Brown, R.3    Rashkin, M.4
  • 7
    • 0034112596 scopus 로고    scopus 로고
    • Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia
    • Davis K., Evans S.L., Campbell R.S., et al. Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia. Crit Care Med 28 (2000) 1412-1418
    • (2000) Crit Care Med , vol.28 , pp. 1412-1418
    • Davis, K.1    Evans, S.L.2    Campbell, R.S.3
  • 8
    • 0028968722 scopus 로고
    • Mechanical ventilation with heated humidifiers or heat and moisture exchangers: effects on patient colonization and incidence of nosocomial pneumonia
    • Dreyfuss D., Djedaini K., Gros I., et al. Mechanical ventilation with heated humidifiers or heat and moisture exchangers: effects on patient colonization and incidence of nosocomial pneumonia. Am J Respir Crit Care Med 151 (1995) 986-992
    • (1995) Am J Respir Crit Care Med , vol.151 , pp. 986-992
    • Dreyfuss, D.1    Djedaini, K.2    Gros, I.3
  • 9
    • 0030879788 scopus 로고    scopus 로고
    • A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion
    • Kirton O.C., DeHaven B., Morgan J., Morejon O., and Civetta J. A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion. Chest 112 (1997) 1055-1059
    • (1997) Chest , vol.112 , pp. 1055-1059
    • Kirton, O.C.1    DeHaven, B.2    Morgan, J.3    Morejon, O.4    Civetta, J.5
  • 10
    • 0031888824 scopus 로고    scopus 로고
    • A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients
    • Kollef M.H., Shapiro S.D., Boyd V., et al. A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients. Chest 113 (1998) 759-767
    • (1998) Chest , vol.113 , pp. 759-767
    • Kollef, M.H.1    Shapiro, S.D.2    Boyd, V.3
  • 11
    • 30444447238 scopus 로고    scopus 로고
    • Impact of humidification systems on ventilator-associated pneumonia: a randomized multicenter trial
    • Lacherade J.C., Auburtin M., Cerf C., et al. Impact of humidification systems on ventilator-associated pneumonia: a randomized multicenter trial. Am J Respir Crit Care Med 172 (2005) 1276-1282
    • (2005) Am J Respir Crit Care Med , vol.172 , pp. 1276-1282
    • Lacherade, J.C.1    Auburtin, M.2    Cerf, C.3
  • 12
    • 0025015270 scopus 로고
    • Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit
    • Martin C., Perrin G., Gevaudan M.J., Saux P., and Gouin F. Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit. Chest 97 (1990) 144-149
    • (1990) Chest , vol.97 , pp. 144-149
    • Martin, C.1    Perrin, G.2    Gevaudan, M.J.3    Saux, P.4    Gouin, F.5
  • 13
    • 0026611461 scopus 로고
    • Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation
    • Roustan J.P., Kienlen J., Aubas P., Aubas S., and du C.J. Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation. Intens Care Med 18 (1992) 97-100
    • (1992) Intens Care Med , vol.18 , pp. 97-100
    • Roustan, J.P.1    Kienlen, J.2    Aubas, P.3    Aubas, S.4    du, C.J.5