메뉴 건너뛰기




Volumn 31, Issue 1, 2007, Pages 51-59

Measuring the effect of field strength on noise amplification factor

Author keywords

High field imaging; Parallel imaging; Reconstruction

Indexed keywords


EID: 33947525707     PISSN: 15525031     EISSN: 1552504X     Source Type: Journal    
DOI: 10.1002/cmr.b.20077     Document Type: Article
Times cited : (2)

References (14)
  • 2
    • 7544231110 scopus 로고    scopus 로고
    • Parallel imaging performance as a function of field strength - an experimental investigation using electrodynamic scaling
    • Wiesinger F, Van de Moortele PF, Adriany G, De Zanche N, Ugurbil K, Pruessmann KP. 2004. Parallel imaging performance as a function of field strength - an experimental investigation using electrodynamic scaling. Magn Reson Med 52:953-964.
    • (2004) Magn Reson Med , vol.52 , pp. 953-964
    • Wiesinger, F.1    Van de Moortele, P.F.2    Adriany, G.3    De Zanche, N.4    Ugurbil, K.5    Pruessmann, K.P.6
  • 4
    • 0023574349 scopus 로고
    • Radiofrequency penetration and absorption in the human body: Limitations to high-field whole-body nuclear magnetic resonance imaging
    • Roschmann P. 1987. Radiofrequency penetration and absorption in the human body: limitations to high-field whole-body nuclear magnetic resonance imaging. Med Phys 14:922-931.
    • (1987) Med Phys , vol.14 , pp. 922-931
    • Roschmann, P.1
  • 6
    • 0033945956 scopus 로고    scopus 로고
    • Sensitivity and power deposition in a high-field imaging experiment
    • Hoult DI. 2000. Sensitivity and power deposition in a high-field imaging experiment. J Magn Reson Imaging 12:46-67.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 46-67
    • Hoult, D.I.1
  • 8
    • 0018306059 scopus 로고
    • A threshold selection method from gray-level histograms
    • Otsu N. 1979. A threshold selection method from gray-level histograms. IEEE Trans Syst Man Cybern 9:62-66.
    • (1979) IEEE Trans Syst Man Cybern , vol.9 , pp. 62-66
    • Otsu, N.1
  • 9
    • 0035744171 scopus 로고    scopus 로고
    • Spatial dependence of a differential shading artifact in images from coil arrays with reactive cross-talk at 1.5 T
    • Tropp J, Schirmer T. 2001. Spatial dependence of a differential shading artifact in images from coil arrays with reactive cross-talk at 1.5 T. J Magn Reson 151:146-151.
    • (2001) J Magn Reson , vol.151 , pp. 146-151
    • Tropp, J.1    Schirmer, T.2
  • 10
    • 0035088714 scopus 로고    scopus 로고
    • Calculations of B(1) distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model
    • Collins CM, Smith MB. 2001. Calculations of B(1) distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model. Magn Reson Med 45:692-699.
    • (2001) Magn Reson Med , vol.45 , pp. 692-699
    • Collins, C.M.1    Smith, M.B.2
  • 11
    • 28444473098 scopus 로고    scopus 로고
    • B(1) destructive interferences and spatial phase patterns at 7T with a head transceiver array coil
    • Van de Moortele PF, Akgun C, Adriany G, Moeller S, Ritter J, Collins CM, et al. 2005. B(1) destructive interferences and spatial phase patterns at 7T with a head transceiver array coil. Magn Reson Med 54:1503-1518.
    • (2005) Magn Reson Med , vol.54 , pp. 1503-1518
    • Van de Moortele, P.F.1    Akgun, C.2    Adriany, G.3    Moeller, S.4    Ritter, J.5    Collins, C.M.6
  • 12
    • 0024411731 scopus 로고
    • Power deposition and noise correlation in NMR samples
    • Carlson JW. 1989. Power deposition and noise correlation in NMR samples. Magn Reson Med 10:399-403.
    • (1989) Magn Reson Med , vol.10 , pp. 399-403
    • Carlson, J.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.