메뉴 건너뛰기




Volumn 48, Issue 5, 2007, Pages 1462-1471

Modelling and evaluation of cooling capacity of earth-air-pipe systems

Author keywords

Cooling capacity; Earth air pipe; Energy conservation; Soil temperature; Space cooling; Thermal performance

Indexed keywords

BUILDINGS; COMPUTATIONAL FLUID DYNAMICS; COOLING SYSTEMS; HEAT TRANSFER; MATHEMATICAL MODELS;

EID: 33947285395     PISSN: 01968904     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enconman.2006.12.021     Document Type: Article
Times cited : (135)

References (29)
  • 1
    • 0242489301 scopus 로고    scopus 로고
    • Optimal placement for air-ground heat transfer systems
    • Stevens J.W. Optimal placement for air-ground heat transfer systems. Appl Thermal Eng 24 (2004) 149-157
    • (2004) Appl Thermal Eng , vol.24 , pp. 149-157
    • Stevens, J.W.1
  • 2
    • 0037332319 scopus 로고    scopus 로고
    • Experimental study of a closed loop vertical ground source heat pump system
    • Hepbasli A., Akdemira O., and Hancioglub E. Experimental study of a closed loop vertical ground source heat pump system. Energy Convers Manage 44 4 (2003) 527-548
    • (2003) Energy Convers Manage , vol.44 , Issue.4 , pp. 527-548
    • Hepbasli, A.1    Akdemira, O.2    Hancioglub, E.3
  • 3
    • 0032816427 scopus 로고    scopus 로고
    • Energy from a two-pipe, earth-to-air heat exchanger
    • Bojic M., Papadakis G., and Kyritsis S. Energy from a two-pipe, earth-to-air heat exchanger. Energy 24 (1999) 519-523
    • (1999) Energy , vol.24 , pp. 519-523
    • Bojic, M.1    Papadakis, G.2    Kyritsis, S.3
  • 4
    • 0344118171 scopus 로고    scopus 로고
    • Energy and exergy analysis of a ground source (geothermal) heat pump system
    • Hepbasli A., and Akdemir O. Energy and exergy analysis of a ground source (geothermal) heat pump system. Energy Convers Manage 45 5 (2004) 737-753
    • (2004) Energy Convers Manage , vol.45 , Issue.5 , pp. 737-753
    • Hepbasli, A.1    Akdemir, O.2
  • 5
    • 0041511798 scopus 로고    scopus 로고
    • Evaluation of earth-to-air heat exchangers with a standardized method to calculate energy efficiency
    • Pfafferott J. Evaluation of earth-to-air heat exchangers with a standardized method to calculate energy efficiency. Energy Build 35 (2003) 971-983
    • (2003) Energy Build , vol.35 , pp. 971-983
    • Pfafferott, J.1
  • 6
    • 0029525703 scopus 로고
    • Parametric prediction of the buried pipes cooling potential for passive cooling applications
    • Mihalakakou G., Santamouris M., Asimakopoulos D., et al. Parametric prediction of the buried pipes cooling potential for passive cooling applications. Solar Energy 55 3 (1995) 163-173
    • (1995) Solar Energy , vol.55 , Issue.3 , pp. 163-173
    • Mihalakakou, G.1    Santamouris, M.2    Asimakopoulos, D.3
  • 7
    • 0029358372 scopus 로고
    • Use of buried pipes for energy conservation in cooling of agricultural greenhouses
    • Santamouris M., Mihalakakou G., Balaras C.A., et al. Use of buried pipes for energy conservation in cooling of agricultural greenhouses. Solar Energy 55 2 (1995) 11-124
    • (1995) Solar Energy , vol.55 , Issue.2 , pp. 11-124
    • Santamouris, M.1    Mihalakakou, G.2    Balaras, C.A.3
  • 8
    • 0033106133 scopus 로고    scopus 로고
    • An experimental study of summer performance of re-circulation type underground air-pipe air-conditioning systems
    • Sawhney R.L., Buddhi D., and Thanu N.M. An experimental study of summer performance of re-circulation type underground air-pipe air-conditioning systems. Build Environ 34 (1999) 189-196
    • (1999) Build Environ , vol.34 , pp. 189-196
    • Sawhney, R.L.1    Buddhi, D.2    Thanu, N.M.3
  • 9
    • 20244376603 scopus 로고    scopus 로고
    • On the ground temperature profile for passive cooling applications in buildings
    • Jacovides C.P., Mihalakakou G., Santamouris M., et al. On the ground temperature profile for passive cooling applications in buildings. Solar Energy 57 3 (1996) 467-475
    • (1996) Solar Energy , vol.57 , Issue.3 , pp. 467-475
    • Jacovides, C.P.1    Mihalakakou, G.2    Santamouris, M.3
  • 10
    • 0029407639 scopus 로고
    • An underground pipe system as an energy source for cooling/heating purposes
    • Jacovides C.P., and Mihalakakou G. An underground pipe system as an energy source for cooling/heating purposes. Renew Energy l6 8 (1995) 893-900
    • (1995) Renew Energy , vol.l6 , Issue.8 , pp. 893-900
    • Jacovides, C.P.1    Mihalakakou, G.2
  • 11
    • 0038683372 scopus 로고    scopus 로고
    • Performance evaluation and energy conservation potential of earth-air-tunnel system coupled with non-air-conditioned building
    • Kumar R., Ramesh R., and Kaushik S.C. Performance evaluation and energy conservation potential of earth-air-tunnel system coupled with non-air-conditioned building. Build Environ 38 (2003) 807-813
    • (2003) Build Environ , vol.38 , pp. 807-813
    • Kumar, R.1    Ramesh, R.2    Kaushik, S.C.3
  • 12
    • 26944489554 scopus 로고    scopus 로고
    • The cooling potential of earth-air heat exchangers for domestic building in a desert climate
    • Al-Ajmi F., Loveday D.L., and Hanby V.I. The cooling potential of earth-air heat exchangers for domestic building in a desert climate. Build Environ 41 (2006) 235-244
    • (2006) Build Environ , vol.41 , pp. 235-244
    • Al-Ajmi, F.1    Loveday, D.L.2    Hanby, V.I.3
  • 13
    • 0036462273 scopus 로고    scopus 로고
    • Ground heat exchanger temperature distribution analysis and experimental verification
    • Bi Y.H., Chen L., and Wu C. Ground heat exchanger temperature distribution analysis and experimental verification. Appl Thermal Eng 22 2 (2002) 183-189
    • (2002) Appl Thermal Eng , vol.22 , Issue.2 , pp. 183-189
    • Bi, Y.H.1    Chen, L.2    Wu, C.3
  • 14
    • 10444286875 scopus 로고    scopus 로고
    • Computational model for a ground coupled space cooling system with an underground energy storage tank
    • Yumruta R., Kanoglu M., Bolatturk A., et al. Computational model for a ground coupled space cooling system with an underground energy storage tank. Energy Build 37 (2005) 353-360
    • (2005) Energy Build , vol.37 , pp. 353-360
    • Yumruta, R.1    Kanoglu, M.2    Bolatturk, A.3
  • 15
    • 5644263860 scopus 로고    scopus 로고
    • Modeling of a space cooling with underground storage
    • Yumruta R., Kanoglu M., Bolatturk A., et al. Modeling of a space cooling with underground storage. Appl Thermal Eng 25 (2005) 227-339
    • (2005) Appl Thermal Eng , vol.25 , pp. 227-339
    • Yumruta, R.1    Kanoglu, M.2    Bolatturk, A.3
  • 16
    • 33947216389 scopus 로고    scopus 로고
    • Wu HJ, Zhu DS, Zou HS, et al. Thermodynamic analysis and simulation of ground source heat pump with adsorption dehumidification. In: Proceedings of the international sorption heat pump conference, 2002, pp. 528-532.
  • 17
    • 0042941688 scopus 로고    scopus 로고
    • Thermodynamic analysis of earth cooling system combined with adsorption dehumidification for air conditioning
    • Wu H.J., Zhu D.S., Li J., et al. Thermodynamic analysis of earth cooling system combined with adsorption dehumidification for air conditioning. J South China Univ Technol 31 7 (2003) 37-41
    • (2003) J South China Univ Technol , vol.31 , Issue.7 , pp. 37-41
    • Wu, H.J.1    Zhu, D.S.2    Li, J.3
  • 18
    • 33947234089 scopus 로고    scopus 로고
    • Wu HJ, Zhu DS, Li J, et al. Thermal performance studies and energy conversation potential of an earth-air-pipe system with desiccant cooling. In: Proceedings of international symposium of enhanced heat transfer & energy conservation, China 2004. p. 1405-11.
  • 19
    • 0026097031 scopus 로고
    • Thermal performance of underground air pipe. Different earth surface treatments
    • Sodha M.S., Buddhi D., and Sawhney R.L. Thermal performance of underground air pipe. Different earth surface treatments. Energy Convers Manage 31 1 (1991) 95-104
    • (1991) Energy Convers Manage , vol.31 , Issue.1 , pp. 95-104
    • Sodha, M.S.1    Buddhi, D.2    Sawhney, R.L.3
  • 20
    • 33947237132 scopus 로고
    • A numerical analysis of heat transfer process in an underground heat tube
    • Sulaiman F. A numerical analysis of heat transfer process in an underground heat tube. J Phys Sci 6 (1995) 57-67
    • (1995) J Phys Sci , vol.6 , pp. 57-67
    • Sulaiman, F.1
  • 21
    • 0006507672 scopus 로고    scopus 로고
    • Analytical model for heat transfer in an underground air tunnel
    • Krarti M., and Kreider J.F. Analytical model for heat transfer in an underground air tunnel. Energy Convers Manage 37 10 (1996) 1561-1574
    • (1996) Energy Convers Manage , vol.37 , Issue.10 , pp. 1561-1574
    • Krarti, M.1    Kreider, J.F.2
  • 22
    • 0032314416 scopus 로고    scopus 로고
    • Cooling effect of cool tube-Part 1: Evaluation of cooling effect without moisture transfer
    • Hokoi Sh., Ueda Sh., and Yoshida T. Cooling effect of cool tube-Part 1: Evaluation of cooling effect without moisture transfer. ASHRAE Trans 104 2 (1998) 398-402
    • (1998) ASHRAE Trans , vol.104 , Issue.2 , pp. 398-402
    • Hokoi, Sh.1    Ueda, Sh.2    Yoshida, T.3
  • 23
    • 0028496177 scopus 로고
    • Modeling the thermal performance of the earth to air heat exchangers
    • Mihalakakou G., Santamouris M., and Asimakopoulos D. Modeling the thermal performance of the earth to air heat exchangers. Solar Energy 53 (1994) 301-305
    • (1994) Solar Energy , vol.53 , pp. 301-305
    • Mihalakakou, G.1    Santamouris, M.2    Asimakopoulos, D.3
  • 25
    • 33947257168 scopus 로고    scopus 로고
    • Jurges W. Der Warmeubergang an einer ebenen Wand (in German), Beih. Z., Gesundheits Ingenieur 1924;19(1):51.
  • 26
    • 85008036022 scopus 로고
    • Effective thermal conductivity of packed beds
    • Wakao N., and Kato K. Effective thermal conductivity of packed beds. J Chem Eng Japan 2 1 (1969) 24-33
    • (1969) J Chem Eng Japan , vol.2 , Issue.1 , pp. 24-33
    • Wakao, N.1    Kato, K.2
  • 27
    • 33947237626 scopus 로고    scopus 로고
    • Spalding DB. PHOENICS Documentation, Version 2.2, CHAM, London, UK, 1995.
  • 28
    • 16644367269 scopus 로고    scopus 로고
    • Numerical simulation of the heat transfer in an earth-air heat exchange system
    • Wu H.J., Zhu D.S., and Sun J.L. Numerical simulation of the heat transfer in an earth-air heat exchange system. J South China Univ Technol 32 11 (2004) 24-27
    • (2004) J South China Univ Technol , vol.32 , Issue.11 , pp. 24-27
    • Wu, H.J.1    Zhu, D.S.2    Sun, J.L.3
  • 29
    • 33947259899 scopus 로고    scopus 로고
    • Wu HJ, Zhu DS, Mao BP, et al. Application of earth cooling system combined with desiccant refrigeration for space cooling in a primary school. International Congress of Refrigeration Washington, DC, 2003 (CDrom).


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.