Volumn 38, Issue 6, 2003, Pages 807-813

Performance evaluation and energy conservation potential of earth-air-tunnel system coupled with non-air-conditioned building

Author keywords

ACH (air change rate); Auxiliary energy load; Cooling heating capacity; Earth air heat exchanger; Soil temperature; Space cooling

Indexed keywords

ATMOSPHERIC HUMIDITY; BUILDING CODES; BUILDINGS; COMPUTER SIMULATION; COOLING; ELECTRIC LOADS; ENERGY CONSERVATION; FAST FOURIER TRANSFORMS; FINITE DIFFERENCE METHOD; HEAT TRANSFER; MASS TRANSFER; TEMPERATURE DISTRIBUTION;

EID: 0038683372     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0360-1323(03)00024-6     Document Type: Article
Times cited : (102)

References (13)
  • 3
    • 0019668691 scopus 로고
    • Temperature distribution inside ground for various surface conditions
    • Bharadwaj S.S. Bansal N.K. Temperature distribution inside ground for various surface conditions ASHRAE 16 3-B 1983 183 192
    • (1983) ASHRAE , vol.16 , Issue.3 B , pp. 183-192
    • Bharadwaj, S.S.1    Bansal, N.K.2
  • 5
    • 84984485414 scopus 로고
    • Solar thermal modelling of a non-airconditioned building: Evaluation of overall heat flux
    • Kaushik S.C. Sodha M.S. Bansal P.K. Bhardwaj S.C. Solar thermal modelling of a non-airconditioned building: evaluation of overall heat flux Energy Research 6 1982 143 160
    • (1982) Energy Research , vol.6 , pp. 143-160
    • Kaushik, S.C.1    Sodha, M.S.2    Bansal, P.K.3    Bhardwaj, S.C.4
  • 6
    • 85047698630 scopus 로고
    • Performance evaluation of an earth air tunnel for space heating of a non air-conditioned building
    • Kaushik S.C. Kumar G.S. Performance evaluation of an earth air tunnel for space heating of a non air-conditioned building International Journal of Ambient Energy 15 3 1994 1 12
    • (1994) International Journal of Ambient Energy , vol.15 , Issue.3 , pp. 1-12
    • Kaushik, S.C.1    Kumar, G.S.2
  • 7
    • 0037500037 scopus 로고    scopus 로고
    • Cooling and heating of buildings with buried earth-tube heat exchanger: An experimental study
    • Chandra M. Puri J.S. Cooling and heating of buildings with buried earth-tube heat exchanger: an experimental study Journal of the Solar Energy Society of India 10 1 2000 1 10
    • (2000) Journal of the Solar Energy Society of India , vol.10 , Issue.1 , pp. 1-10
    • Chandra, M.1    Puri, J.S.2
  • 8
    • 0028483509 scopus 로고
    • Optimization of earth-air-tunnel system for space cooling
    • Singh S.P. Optimization of earth-air-tunnel system for space cooling Energy Conversion and Management 35 8 1994 721 725
    • (1994) Energy Conversion and Management , vol.35 , Issue.8 , pp. 721-725
    • Singh, S.P.1
  • 10
    • 0021938029 scopus 로고
    • Evaluation of an earth-air-tunnel system for cooling/heating of a hospital complex
    • Sodha M.S. Sharma A.K. Singh S.P. Bansal N.K. Kumar A. Evaluation of an earth-air-tunnel system for cooling/heating of a hospital complex Building and Environment 20 2 1985 115 122
    • (1985) Building and Environment , vol.20 , Issue.2 , pp. 115-122
    • Sodha, M.S.1    Sharma, A.K.2    Singh, S.P.3    Bansal, N.K.4    Kumar, A.5
  • 11
    • 0026711820 scopus 로고
    • Analysis of the accuracy and sensitivity of eight models to predict the performance of earth-to-air heat exchangers
    • Tzaferis A. Liparkis D. Analysis of the accuracy and sensitivity of eight models to predict the performance of earth-to-air heat exchangers Energy and Buildings 18 1992 35 43
    • (1992) Energy and Buildings , vol.18 , pp. 35-43
    • Tzaferis, A.1    Liparkis, D.2
  • 12
    • 0028425502 scopus 로고
    • Design and operation of a low energy consumption passive solar agricultural greenhouse
    • Santamouris M, Argiriou, Vallindras M. Design and operation of a low energy consumption passive solar agricultural greenhouse. Solar Energy 1994;52(5).
    • (1994) Solar Energy , vol.52 , Issue.5
    • Santamouris, M.1    Argiriou Vallindras, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.