메뉴 건너뛰기




Volumn 17, Issue 2, 2006, Pages 139-152

First-degree atrioventricular block: Clinical manifestations, indications for pacing, pacemaker management & consequences during cardiac resynchronization

Author keywords

Atrial undersensing; Biventricular pacing; Cardiac pacing; Cardiac resynchronization; First degree atrioventricular block; Heart failure

Indexed keywords

ARTIFICIAL HEART PACEMAKER; ATRIOVENTRICULAR BLOCK; CARDIAC RESYNCHRONIZATION THERAPY; CLINICAL EVALUATION; CLINICAL FEATURE; CONGESTIVE CARDIOMYOPATHY; CONGESTIVE HEART FAILURE; DIFFERENTIAL DIAGNOSIS; ECG ABNORMALITY; ELECTROCARDIOGRAPHY MONITORING; EXERCISE TEST; HEART ATRIUM PACING; HEART FAILURE; HEART HEMODYNAMICS; HEART LEFT VENTRICLE CONTRACTION; HEART LEFT VENTRICLE ENDDIASTOLIC PRESSURE; HEART LEFT VENTRICLE FUNCTION; HEART MUSCLE CONDUCTION DISTURBANCE; HEART PRELOAD; HEART RATE; HEART RIGHT VENTRICLE; HEART VENTRICLE PACING; HEART VETRICULOATRIAL CONDUCTION BLOCK; HUMAN; LONG PR INTERVAL; MITRAL VALVE REGURGITATION; PACEMAKER LIKE SYNDROME; PRIORITY JOURNAL; REVIEW; RISK ASSESSMENT; SYSTOLE; TACHYCARDIA; TREADMILL EXERCISE; TREATMENT INDICATION; TREATMENT OUTCOME; WAVEFORM;

EID: 33947282900     PISSN: 1383875X     EISSN: 15728595     Source Type: Journal    
DOI: 10.1007/s10840-006-9065-x     Document Type: Review
Times cited : (91)

References (51)
  • 1
    • 0242701713 scopus 로고
    • Pacemaker syndrome without a pacemaker. Deleterious effects of firstdegree AV block
    • Abstract
    • Chirife, R., Ortega, D. F., & Salazar, A. I. (1990). "Pacemaker syndrome" without a pacemaker. Deleterious effects of firstdegree AV block. RBM, 12, 22. (Abstract)
    • (1990) RBM , vol.12 , pp. 22
    • Chirife, R.1    Ortega, D.F.2    Salazar, A.I.3
  • 6
    • 0347422433 scopus 로고
    • Deleterious hemodynamic consequences of isolated long PR intervals: Correction by DDD pacing
    • Abstract Suppl
    • Mabo, P., Varin, C., Vauthier, M., et al. (1992). Deleterious hemodynamic consequences of isolated long PR intervals: correction by DDD pacing. European Heart Journal, 13, 225. (Abstract Suppl)
    • (1992) European Heart Journal , vol.13 , pp. 225
    • Mabo, P.1    Varin, C.2    Vauthier, M.3
  • 7
    • 0030143986 scopus 로고    scopus 로고
    • Barold, S. S. (1996). Indications for permanent pacing in firstdegree block. Class I, II, or III? Pacing and Clinical Electrophysiology, 19, 747-751.
    • Barold, S. S. (1996). Indications for permanent pacing in firstdegree block. Class I, II, or III? Pacing and Clinical Electrophysiology, 19, 747-751.
  • 8
    • 0036852227 scopus 로고    scopus 로고
    • ACC/AHA/NASPE 2002 guideline update for implantation of cardiac pacemakers and antiarrhythmia devices: Summary article. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines)
    • Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., et al. (2002). ACC/AHA/NASPE 2002 guideline update for implantation of cardiac pacemakers and antiarrhythmia devices: Summary article. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines). Journal of Cardiovascular Electrophysiology, 13, 1183-1199.
    • (2002) Journal of Cardiovascular Electrophysiology , vol.13 , pp. 1183-1199
    • Gregoratos, G.1    Abrams, J.2    Epstein, A.E.3    Freedman, R.A.4    Hayes, D.L.5    Hlatky, M.A.6
  • 9
    • 0023873284 scopus 로고
    • Diastolic mitral and tricuspid regurgitation by Doppler echocardiography in patients with atrioventricular block: New insight into the mechanism of atrioventricular valve closure
    • Schnittger, I., Appleton, C. P., Hatle, L. K., & Popp, R. L. (1988). Diastolic mitral and tricuspid regurgitation by Doppler echocardiography in patients with atrioventricular block: New insight into the mechanism of atrioventricular valve closure. Journal of the American College of Cardiology, 11, 83-88.
    • (1988) Journal of the American College of Cardiology , vol.11 , pp. 83-88
    • Schnittger, I.1    Appleton, C.P.2    Hatle, L.K.3    Popp, R.L.4
  • 10
    • 0025866466 scopus 로고
    • Diastolic mitral regurgitation with atrioventricular conduction abnormalities: Relation of mitral flow velocity to transmitral pressure gradients in conscious dogs
    • Appleton, C. P., Basnight, M. A., & Gonzalez, M. S. (1991). Diastolic mitral regurgitation with atrioventricular conduction abnormalities: Relation of mitral flow velocity to transmitral pressure gradients in conscious dogs. Journal of the American College of Cardiology, 18, 843-849.
    • (1991) Journal of the American College of Cardiology , vol.18 , pp. 843-849
    • Appleton, C.P.1    Basnight, M.A.2    Gonzalez, M.S.3
  • 11
    • 0022618926 scopus 로고
    • Diastolic mitral regurgitation in patients with atrioventricular conduction abnormalities: A common finding by Doppler echocardiography
    • Panidis, I. P., Ross, J., Munley, B., Nestico, P., & Mintz, G. S. (1986). Diastolic mitral regurgitation in patients with atrioventricular conduction abnormalities: A common finding by Doppler echocardiography. Journal of the American College of Cardiology, 7, 768-774.
    • (1986) Journal of the American College of Cardiology , vol.7 , pp. 768-774
    • Panidis, I.P.1    Ross, J.2    Munley, B.3    Nestico, P.4    Mintz, G.S.5
  • 12
    • 0028043703 scopus 로고
    • Critical PQ interval for the appearance of diastolic mitral regurgitation and optimal PQ interval in patients implanted with DDD pacemakers
    • Ishikawa, T., Sumica, S., Kimura, K., Kuji, N., Nakayama, R., Nagura, T., et al. (1994). Critical PQ interval for the appearance of diastolic mitral regurgitation and optimal PQ interval in patients implanted with DDD pacemakers. Pacing and Clinical Electrophysiology, 17, 1989-1994.
    • (1994) Pacing and Clinical Electrophysiology , vol.17 , pp. 1989-1994
    • Ishikawa, T.1    Sumica, S.2    Kimura, K.3    Kuji, N.4    Nakayama, R.5    Nagura, T.6
  • 13
    • 0028797006 scopus 로고
    • Mechanism of hemodynamic improvement by dualchamber pacing for severe left ventricular dysfunction; an acute doppler and catheterization hemodynamic study
    • Nishimura, R. A., Hayes, D. L., Holmes, D. R. Jr, & Tajik, A. J. (1995). Mechanism of hemodynamic improvement by dualchamber pacing for severe left ventricular dysfunction; an acute doppler and catheterization hemodynamic study. Journal of the American College of Cardiology, 25, 281-288.
    • (1995) Journal of the American College of Cardiology , vol.25 , pp. 281-288
    • Nishimura, R.A.1    Hayes, D.L.2    Holmes Jr, D.R.3    Tajik, A.J.4
  • 14
    • 0013974904 scopus 로고
    • Atriogenic diastolic reflux in patients with atrioventricular block
    • Rutishauser, W., Wirz, P., Gander, M., & Luthy, E. (1966). Atriogenic diastolic reflux in patients with atrioventricular block. Circulation, 34, 807-817.
    • (1966) Circulation , vol.34 , pp. 807-817
    • Rutishauser, W.1    Wirz, P.2    Gander, M.3    Luthy, E.4
  • 15
    • 0024227377 scopus 로고
    • Pacemaker syndrome with AAI rate variable pacing: Importance of atrioventricular conduction properties, medication, and pacemaker programmability
    • den Dulk, K., Lindemans, F. W., Brugada, P., Smeets, J. L., & Wellens, H. J. (1988). Pacemaker syndrome with AAI rate variable pacing: Importance of atrioventricular conduction properties, medication, and pacemaker programmability. Pacing and Clinical Electrophysiology, 11, 1226-1233.
    • (1988) Pacing and Clinical Electrophysiology , vol.11 , pp. 1226-1233
    • den Dulk, K.1    Lindemans, F.W.2    Brugada, P.3    Smeets, J.L.4    Wellens, H.J.5
  • 16
    • 26444599967 scopus 로고    scopus 로고
    • Multicenter, prospective, randomized safety and efficacy study of a new atrial-based managed ventricular pacing mode (MVP) in dual chamber ICDs
    • Sweeney, M. O., Ellenbogen, K. A., Casavant, D., Betzold, R., Sheldon, T., Tang, F., et al. (2005). Multicenter, prospective, randomized safety and efficacy study of a new atrial-based managed ventricular pacing mode (MVP) in dual chamber ICDs. Journal of Cardiovascular Electrophysiology, 16, 811-817.
    • (2005) Journal of Cardiovascular Electrophysiology , vol.16 , pp. 811-817
    • Sweeney, M.O.1    Ellenbogen, K.A.2    Casavant, D.3    Betzold, R.4    Sheldon, T.5    Tang, F.6
  • 20
    • 0029011512 scopus 로고
    • Hemodynamic importance of preserving the normal sequence of ventricular activation in permanent cardiac pacing
    • Leclercq, C., Gras, D., Le Helloco, A., Nicol, L., Mabo, P., & Daubert, C. (1995). Hemodynamic importance of preserving the normal sequence of ventricular activation in permanent cardiac pacing. American Heart Journal, 129, 1133-1141.
    • (1995) American Heart Journal , vol.129 , pp. 1133-1141
    • Leclercq, C.1    Gras, D.2    Le Helloco, A.3    Nicol, L.4    Mabo, P.5    Daubert, C.6
  • 23
    • 0026325531 scopus 로고
    • Lack of physiological adaptation of the atrioventricular interval to heart rate in patients chronically paced in the AAIR mode
    • Mabo, P., Pouillot, C., Kermarrec, A., Lelong, B., Lebreton, H., & Daubert, C. (1991). Lack of physiological adaptation of the atrioventricular interval to heart rate in patients chronically paced in the AAIR mode. Pacing and Clinical Electrophysiology, 14, 2133-2142.
    • (1991) Pacing and Clinical Electrophysiology , vol.14 , pp. 2133-2142
    • Mabo, P.1    Pouillot, C.2    Kermarrec, A.3    Lelong, B.4    Lebreton, H.5    Daubert, C.6
  • 25
    • 0033978778 scopus 로고    scopus 로고
    • Preserving normal ventricular activation versus atrioventricular delay optimization during pacing: The role of intrinsic atrioventricular conduction and pacing rate
    • Iliev, I. I., Yamachika, S., Muta, K., Hayano, M., Ishimatsu, T., Nakao, K., et al. (2000). Preserving normal ventricular activation versus atrioventricular delay optimization during pacing: The role of intrinsic atrioventricular conduction and pacing rate. Pacing and Clinical Electrophysiology, 23, 74-80.
    • (2000) Pacing and Clinical Electrophysiology , vol.23 , pp. 74-80
    • Iliev, I.I.1    Yamachika, S.2    Muta, K.3    Hayano, M.4    Ishimatsu, T.5    Nakao, K.6
  • 26
    • 32044474926 scopus 로고    scopus 로고
    • Harmful effects of long-term right ventricular pacing
    • Barold, S. S., & Stroobandt, R. X. (2006). Harmful effects of long-term right ventricular pacing. Acta Cardiologica, 61, 103-110.
    • (2006) Acta Cardiologica , vol.61 , pp. 103-110
    • Barold, S.S.1    Stroobandt, R.X.2
  • 27
    • 0033962463 scopus 로고    scopus 로고
    • Pacing for patients with congestive heart failure and dilated cardiomyopathy
    • Peters, R. W., & Gold, M. R. (2000). Pacing for patients with congestive heart failure and dilated cardiomyopathy. Cardiovascular Clinics, 18, 55-66.
    • (2000) Cardiovascular Clinics , vol.18 , pp. 55-66
    • Peters, R.W.1    Gold, M.R.2
  • 28
    • 33745636160 scopus 로고    scopus 로고
    • Effects of right ventricular pacing on intra-left ventricular electromechanical activation in patients with native narrow QRS
    • Lupi, G., Sassone, B., Badano, L., Peraldo, C., Gaddi, O., Sitges, M., et al. (2006). Effects of right ventricular pacing on intra-left ventricular electromechanical activation in patients with native narrow QRS. American Journal of Cardiology, 98, 219-222.
    • (2006) American Journal of Cardiology , vol.98 , pp. 219-222
    • Lupi, G.1    Sassone, B.2    Badano, L.3    Peraldo, C.4    Gaddi, O.5    Sitges, M.6
  • 29
    • 33749521290 scopus 로고    scopus 로고
    • Right ventricular pacing can induce ventricular dyssynchrony in patients with atrial fibrillation after atrioventricular node ablation
    • Tops, L. F., Schalij, M. J., Holman, E. R., van Erven, L., van der Wall, E. E., & Bax, J. J. (2006). Right ventricular pacing can induce ventricular dyssynchrony in patients with atrial fibrillation after atrioventricular node ablation. Journal of the American College of Cardiology, 48, 1642-1648.
    • (2006) Journal of the American College of Cardiology , vol.48 , pp. 1642-1648
    • Tops, L.F.1    Schalij, M.J.2    Holman, E.R.3    van Erven, L.4    van der Wall, E.E.5    Bax, J.J.6
  • 30
    • 33646443390 scopus 로고    scopus 로고
    • Heart failure during cardiac pacing
    • Sweeney, M. O., & Hellkamp, A. S. (2006). Heart failure during cardiac pacing. Circulation, 113, 2082-2088.
    • (2006) Circulation , vol.113 , pp. 2082-2088
    • Sweeney, M.O.1    Hellkamp, A.S.2
  • 31
    • 33749535685 scopus 로고    scopus 로고
    • Selection of permanent ventricular pacing site: How far should we go?
    • Tse, H. F., & Lau, C. P. (2006). Selection of permanent ventricular pacing site: How far should we go? Journal of the American College of Cardiology, 48, 1649-1651.
    • (2006) Journal of the American College of Cardiology , vol.48 , pp. 1649-1651
    • Tse, H.F.1    Lau, C.P.2
  • 32
    • 33745085195 scopus 로고    scopus 로고
    • Primary prevention of heart failure in cardiac pacing
    • Barold, S. S., & Lau, C. P. (2006). Primary prevention of heart failure in cardiac pacing. Pacing and Clinical Electrophysiology, 29, 217-219.
    • (2006) Pacing and Clinical Electrophysiology , vol.29 , pp. 217-219
    • Barold, S.S.1    Lau, C.P.2
  • 33
    • 0032705349 scopus 로고    scopus 로고
    • Pacemaker inhibition due to prolonged native AV interval in dual-chamber devices
    • Bode, F., Wiegand, U., Katus, H. A., & Potratz, J. (1999). Pacemaker inhibition due to prolonged native AV interval in dual-chamber devices. Pacing and Clinical Electrophysiology, 22, 1425-1431.
    • (1999) Pacing and Clinical Electrophysiology , vol.22 , pp. 1425-1431
    • Bode, F.1    Wiegand, U.2    Katus, H.A.3    Potratz, J.4
  • 34
    • 0024445291 scopus 로고
    • Undersensing of P waves in the presence of adequate P wave due to automatic postventricular atrial refractory period extension
    • Wilson, J. H., & Lattner, S. (1989). Undersensing of P waves in the presence of adequate P wave due to automatic postventricular atrial refractory period extension. Pacing and Clinical Electrophysiology, 10, 1729-1732.
    • (1989) Pacing and Clinical Electrophysiology , vol.10 , pp. 1729-1732
    • Wilson, J.H.1    Lattner, S.2
  • 37
    • 0013559413 scopus 로고
    • Functional loss of atrial sensing causing sustained first to high-degree AV block in patients with dual-chamber pacemakers (abstract)
    • Dodinot, B., Beurrier, D., Simon, J. P., & Sadoul, N. (1993). "Functional" loss of atrial sensing causing sustained first to high-degree AV block in patients with dual-chamber pacemakers (abstract). Pacing and Clinical Electrophysiology, 16, 1189.
    • (1993) Pacing and Clinical Electrophysiology , vol.16 , pp. 1189
    • Dodinot, B.1    Beurrier, D.2    Simon, J.P.3    Sadoul, N.4
  • 38
    • 0002283539 scopus 로고    scopus 로고
    • Timing cycles and operational characteristics of pacemakers
    • K. Ellenbogen, N. Kay, & B. Wilkoff Eds, 2nd ed, Philadelphia PA: W.B. Saunders
    • Barold, S. S. (2000). Timing cycles and operational characteristics of pacemakers. In K. Ellenbogen, N. Kay, & B. Wilkoff (Eds.), Clinical cardiac pacing and defibrillation (pp. 727-825), (2nd ed.). Philadelphia PA: W.B. Saunders.
    • (2000) Clinical cardiac pacing and defibrillation , pp. 727-825
    • Barold, S.S.1
  • 39
    • 26844500625 scopus 로고    scopus 로고
    • Ventriculo-atrial gradient due to first degree atrio-ventricular block: A case report
    • Ando', G., & Versaci, F. (2005). Ventriculo-atrial gradient due to first degree atrio-ventricular block: A case report. BMC Cardiovascular Disorders, 5, 23.
    • (2005) BMC Cardiovascular Disorders , vol.5 , pp. 23
    • Ando', G.1    Versaci, F.2
  • 42
    • 0032935113 scopus 로고    scopus 로고
    • Sustained inhibition of a DDD pacemaker at rates below the programmed lower rate during automatic PVARP extension
    • Barold, S. S. (1999). Sustained inhibition of a DDD pacemaker at rates below the programmed lower rate during automatic PVARP extension. Pacing and Clinical Electrophysiology, 22, 521-524.
    • (1999) Pacing and Clinical Electrophysiology , vol.22 , pp. 521-524
    • Barold, S.S.1
  • 45
    • 0025814759 scopus 로고
    • Catheter ablation of ventriculoatrial conduction in the treatment of pacemaker mediated tachycardia
    • Pitney, M., & Davis, M. (1991). Catheter ablation of ventriculoatrial conduction in the treatment of pacemaker mediated tachycardia. Pacing and Clinical Electrophysiology, 14, 1013-1017.
    • (1991) Pacing and Clinical Electrophysiology , vol.14 , pp. 1013-1017
    • Pitney, M.1    Davis, M.2
  • 48
    • 33645211727 scopus 로고    scopus 로고
    • Clinical predictors and timing of New York Heart Association class improvement with cardiac resynchronization therapy in patients with advanced chronic heart failure: Results from the Multicenter InSync Randomized Clinical Evaluation (MIRACLE) and Multicenter InSync ICD Randomized Clinical Evaluation (MIRACLE-ICD) trials
    • & MIRACLE and MIRACLE-ICD Investigators
    • Pires, L. A., Abraham, W. T., Young, J. B., Johnson, K. M., & MIRACLE and MIRACLE-ICD Investigators (2006). Clinical predictors and timing of New York Heart Association class improvement with cardiac resynchronization therapy in patients with advanced chronic heart failure: results from the Multicenter InSync Randomized Clinical Evaluation (MIRACLE) and Multicenter InSync ICD Randomized Clinical Evaluation (MIRACLE-ICD) trials. American Heart Journal, 151, 837-843.
    • (2006) American Heart Journal , vol.151 , pp. 837-843
    • Pires, L.A.1    Abraham, W.T.2    Young, J.B.3    Johnson, K.M.4
  • 49
    • 33744518036 scopus 로고    scopus 로고
    • Relation of right ventricular peak systolic pressure to major adverse events in patients undergoing cardiac resynchronization therapy
    • Tedrow, U. B., Kramer, D. B., Stevenson, L. W., Stevenson, W. G., Baughman, K. L., Epstein, L. M., et al. (2006). Relation of right ventricular peak systolic pressure to major adverse events in patients undergoing cardiac resynchronization therapy. American Journal of Cardiology, 97, 1737-1740.
    • (2006) American Journal of Cardiology , vol.97 , pp. 1737-1740
    • Tedrow, U.B.1    Kramer, D.B.2    Stevenson, L.W.3    Stevenson, W.G.4    Baughman, K.L.5    Epstein, L.M.6
  • 50
    • 27844514301 scopus 로고    scopus 로고
    • Invasive optimization of cardiac resynchronization therapy: Role of sequential biventricular and left ventricular pacing
    • Kurzidim, K., Reinke, H., Sperzel, J., Schneider, H. J., Danilovic, D., Siemon, G., et al. (2005). Invasive optimization of cardiac resynchronization therapy: Role of sequential biventricular and left ventricular pacing. Pacing and Clinical Electrophysiology, 28, 754-761.
    • (2005) Pacing and Clinical Electrophysiology , vol.28 , pp. 754-761
    • Kurzidim, K.1    Reinke, H.2    Sperzel, J.3    Schneider, H.J.4    Danilovic, D.5    Siemon, G.6
  • 51
    • 28944455512 scopus 로고    scopus 로고
    • The hemodynamic effect of intrinsic conduction during left ventricular pacing as compared to biventricular pacing
    • van Gelder, B. M., Bracke, F. A., Meijer, A., & Pijls, N. H. (2005). The hemodynamic effect of intrinsic conduction during left ventricular pacing as compared to biventricular pacing. Journal of the American College of Cardiology, 4(6), 2305-2310.
    • (2005) Journal of the American College of Cardiology , vol.4 , Issue.6 , pp. 2305-2310
    • van Gelder, B.M.1    Bracke, F.A.2    Meijer, A.3    Pijls, N.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.