Volumn 22, Issue 6 I, 1999, Pages 894-902

Diagnosis of atrial undersensing in dual chamber pacemakers: Impact of autodiagnostic features

Author keywords

Atrial sensing; Autodiagnostic features; Dual chamber pacemaker; Holter monitoring; Treadmill exercise; VDD pacing

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; ATRIOVENTRICULAR BLOCK; BODY POSITION; BREATHING; COMPUTER ASSISTED DIAGNOSIS; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; ELECTROCARDIOGRAPHY; FEMALE; FOLLOW UP; HEART ATRIUM FIBRILLATION; HISTOGRAM; HOLTER MONITORING; HUMAN; MAJOR CLINICAL STUDY; MALE; P WAVE; SINUS BRADYCARDIA; TELEMETRY; TREADMILL EXERCISE; COMPARATIVE STUDY; EQUIPMENT; EQUIPMENT DESIGN; EXERCISE TEST; HEART ATRIOVENTRICULAR NODE; HEART BLOCK; INSTRUMENTATION; MIDDLE AGED; PATHOPHYSIOLOGY; SENSITIVITY AND SPECIFICITY;

EID: 0032971419     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1999.tb06813.x     Document Type: Article
Times cited : (15)

References (17)
  • 1
    • 0028923632 scopus 로고
    • Cardiac output in single-lead VDD-pacing versus rate-matched VVIR pacing
    • Nowak B, Voigtlaender T, Himmrich E, et al. Cardiac output in single-lead VDD-pacing versus rate-matched VVIR pacing. Am J Cardiol 1995; 75:904-907.
    • (1995) Am J Cardiol , vol.75 , pp. 904-907
    • Nowak, B.1    Voigtlaender, T.2    Himmrich, E.3
  • 2
    • 0026577156 scopus 로고
    • Longevity in patients with high degree atrioventricular block paced in the atrial synchronous or the fixed rate ventricular inhibited mode
    • Linde-Edelstam C, Gullberg B, Norlander R, et al. Longevity in patients with high degree atrioventricular block paced in the atrial synchronous or the fixed rate ventricular inhibited mode. PACE 1992; 15:304-313.
    • (1992) PACE , vol.15 , pp. 304-313
    • Linde-Edelstam, C.1    Gullberg, B.2    Norlander, R.3
  • 3
    • 0028027767 scopus 로고
    • Long-term stability of p-wave sensing in single-lead VDDR pacing; clinical versus subclinical atrial undersensing
    • Lau CP, Tai YT, Leung SK, et al. Long-term stability of p-wave sensing in single-lead VDDR pacing; Clinical versus subclinical atrial undersensing. PACE 1994; 17:1849-1853.
    • (1994) PACE , vol.17 , pp. 1849-1853
    • Lau, C.P.1    Tai, Y.T.2    Leung, S.K.3
  • 4
    • 0343671953 scopus 로고
    • Assessment of transient pacemaker dysfunction and spontaneous arrhythmias in patients with dual chamber pacemakers - A Holter monitoring study
    • Brandes A, Brudna C, Potratz J, et al. Assessment of transient pacemaker dysfunction and spontaneous arrhythmias in patients with dual chamber pacemakers - A Holter monitoring study. Herzschr Elektrophys 1995; 6:47-58.
    • (1995) Herzschr Elektrophys , vol.6 , pp. 47-58
    • Brandes, A.1    Brudna, C.2    Potratz, J.3
  • 5
    • 0345309934 scopus 로고    scopus 로고
    • Should unipolar leads be implanted in the atrium? A Holter-electrocardiographic comparison of threshold-adapted unipolar and high-sensitive bipolar sensing
    • in press
    • Wiegand UKH, Schier H, Bode F, et al. Should unipolar leads be implanted in the atrium? A Holter-electrocardiographic comparison of threshold-adapted unipolar and high-sensitive bipolar sensing. PACE (in press).
    • PACE
    • Wiegand, U.K.H.1    Schier, H.2    Bode, F.3
  • 6
    • 0029011296 scopus 로고
    • Atrial sensing by a new VDD pacemaker
    • Voigtlander T, Nowak B, Treese N, et al. Atrial sensing by a new VDD pacemaker. Z Kardiol 1995; 84:459-467.
    • (1995) Z Kardiol , vol.84 , pp. 459-467
    • Voigtlander, T.1    Nowak, B.2    Treese, N.3
  • 7
    • 0031064797 scopus 로고    scopus 로고
    • Atrial sensing and AV-synchrony in single-lead VDD-pacemakers. Is the occurrence of atrial undersensing predictable?
    • Wiegand UKH, Schneider R, Bode F, et al. Atrial sensing and AV-synchrony in single-lead VDD-pacemakers. Is the occurrence of atrial undersensing predictable? Z Kardiol 1997; 86:95-104.
    • (1997) Z Kardiol , vol.86 , pp. 95-104
    • Wiegand, U.K.H.1    Schneider, R.2    Bode, F.3
  • 8
    • 0030724159 scopus 로고    scopus 로고
    • Holter, loop recorder and event counter capabilities of implanted devices
    • Waktare JEP, Malik M. Holter, loop recorder and event counter capabilities of implanted devices. PACE 1997; 20:2658-2669.
    • (1997) PACE , vol.20 , pp. 2658-2669
    • Waktare, J.E.P.1    Malik, M.2
  • 9
    • 0019776294 scopus 로고
    • Pacemaker assessment in the ambulant patient
    • Murray A, Jordan RS, Gold RG. Pacemaker assessment in the ambulant patient. Br Heart J 1981; 46:531-538.
    • (1981) Br Heart J , vol.46 , pp. 531-538
    • Murray, A.1    Jordan, R.S.2    Gold, R.G.3
  • 11
    • 0027379973 scopus 로고
    • Atrial sensing performance of the single-lead VDD pacemaker during exercise
    • Varialle P, Chryssos BE. Atrial sensing performance of the single-lead VDD pacemaker during exercise. J Am Coll Cardiol 1993; 22:1854-1857.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1854-1857
    • Varialle, P.1    Chryssos, B.E.2
  • 12
    • 0023915775 scopus 로고
    • Atrial sensing performance of AV universal pacemakers during exercise
    • Frohlig G, Blank W, Schwerdt H, et al. Atrial sensing performance of AV universal pacemakers during exercise. PACE 1988; 11:47-60.
    • (1988) PACE , vol.11 , pp. 47-60
    • Frohlig, G.1    Blank, W.2    Schwerdt, H.3
  • 13
    • 0021963735 scopus 로고
    • Pacemaker-mediated tachycardia initiated by coincident P-wave undersensing and ventricular blanking period
    • Lamas GA, Antman EM. Pacemaker-mediated tachycardia initiated by coincident P-wave undersensing and ventricular blanking period. PACE 1985:8:436-439.
    • (1985) PACE , vol.8 , pp. 436-439
    • Lamas, G.A.1    Antman, E.M.2
  • 14
    • 0344446947 scopus 로고    scopus 로고
    • Probleme bei der berechnung der AV-synchronität von VDD-schrittmachen
    • Israel CW, Floren E, Weber K, et al. Probleme bei der Berechnung der AV-Synchronität von VDD-Schrittmachen. (abstract) HzSchr Electrophys 1997; 8:86.
    • (1997) HzSchr Electrophys , vol.8 , pp. 86
    • Israel, C.W.1    Floren, E.2    Weber, K.3
  • 15
    • 0024445291 scopus 로고
    • Undersensing of P waves in the presence of an adequate p wave due to automatic postventricular atrial refractory period extension
    • Wilson JH, Lattner S. Undersensing of P waves in the presence of an adequate P wave due to automatic postventricular atrial refractory period extension. PACE 1989; 12:1729-1732.
    • (1989) PACE , vol.12 , pp. 1729-1732
    • Wilson, J.H.1    Lattner, S.2
  • 16
    • 0028109708 scopus 로고
    • Avoiding atrial undersensing by assessment of P-wave histogram data
    • Boute W, Albers GA, Giele V. Avoiding atrial undersensing by assessment of P-wave histogram data. PACE 1994; 17:1878-1882.
    • (1994) PACE , vol.17 , pp. 1878-1882
    • Boute, W.1    Albers, G.A.2    Giele, V.3
  • 17
    • 0030937146 scopus 로고    scopus 로고
    • Determinating optimal atrial sensitivity settings for single-lead VDD-pacing: The importance of the P-wave histogram
    • Langford EJ, Smith RE, McCrea WA, et al. Determinating optimal atrial sensitivity settings for single-lead VDD-pacing: The importance of the P-wave histogram. PACE 1997; 20:619-623.
    • (1997) PACE , vol.20 , pp. 619-623
    • Langford, E.J.1    Smith, R.E.2    McCrea, W.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.