메뉴 건너뛰기




Volumn 23, Issue 2, 2007, Pages 139-142

Impact of intracardiac echocardiography on radiation exposure during adult congenital heart disease catheter-based interventions

Author keywords

Catheterization; Congenital Heart Disease; Interventional; Intracardiac echocardiography; Radiation

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CLINICAL ASSESSMENT; CONGENITAL HEART DISEASE; CONTROLLED STUDY; DOSIMETRY; ECHOCARDIOGRAPHY; FEMALE; HEART ATRIUM SEPTUM DEFECT; HEART CATHETERIZATION; HEART SURGERY; HUMAN; INTERMETHOD COMPARISON; MALE; OPERATION DURATION; PATIENT REFERRAL; RADIATION DOSE DISTRIBUTION; RADIATION EXPOSURE; SCLEROTHERAPY; STATISTICAL SIGNIFICANCE;

EID: 33947241918     PISSN: 15695794     EISSN: 18758312     Source Type: Journal    
DOI: 10.1007/s10554-006-9125-4     Document Type: Article
Times cited : (11)

References (20)
  • 2
    • 0037134834 scopus 로고    scopus 로고
    • Intracardiac echocardiography-guided, anatomically based radiofrequency ablation of focal atrial fibrillation originating from pulmonary veins
    • Mangrum JM, Mounsey JP, Kok LC, DiMarco JP, Haines DE (2002) Intracardiac echocardiography-guided, anatomically based radiofrequency ablation of focal atrial fibrillation originating from pulmonary veins. J Am Coll Cardiol 39:1964-1972
    • (2002) J Am Coll Cardiol , vol.39 , pp. 1964-1972
    • Mangrum, J.M.1    Mounsey, J.P.2    Kok, L.C.3    DiMarco, J.P.4    Haines, D.E.5
  • 3
    • 0030024604 scopus 로고    scopus 로고
    • Usefulness of intracardiac echocardiography in complex transseptal catheterization during percutaneous transvenous mitral commissurotomy
    • Hung JS, Fu M, Yeh KH, Wu CJ, Wong P (1996) Usefulness of intracardiac echocardiography in complex transseptal catheterization during percutaneous transvenous mitral commissurotomy. Mayo Clin Proc 71:134-140
    • (1996) Mayo Clin Proc , vol.71 , pp. 134-140
    • Hung, J.S.1    Fu, M.2    Yeh, K.H.3    Wu, C.J.4    Wong, P.5
  • 4
    • 0035143017 scopus 로고    scopus 로고
    • Transcatheter closure of atrial septal defects and patent foramen ovale under intracardiac echocardiographic guidance: Feasibility and comparison with transesophageal echocardiography
    • Hijazi Z, Wang Z, Cao Q, Koenig P, Waight D, Lang R (2001) Transcatheter closure of atrial septal defects and patent foramen ovale under intracardiac echocardiographic guidance: Feasibility and comparison with transesophageal echocardiography. Catheter Cardiovasc Interv 52:194-199
    • (2001) Catheter Cardiovasc Interv , vol.52 , pp. 194-199
    • Hijazi, Z.1    Wang, Z.2    Cao, Q.3    Koenig, P.4    Waight, D.5    Lang, R.6
  • 5
    • 0037327570 scopus 로고    scopus 로고
    • Intracardiac echocardiography and transcranial Doppler ultrasound to guide closure of patent foramen ovale
    • Zanchetta M, Rigatelli G, Onorato E (2003) Intracardiac echocardiography and transcranial Doppler ultrasound to guide closure of patent foramen ovale. J Invasive Cardiol 15:93-96
    • (2003) J Invasive Cardiol , vol.15 , pp. 93-96
    • Zanchetta, M.1    Rigatelli, G.2    Onorato, E.3
  • 6
    • 27744545009 scopus 로고    scopus 로고
    • Expanding the use of intracardiac echocardiography in congenital heart disease catheter-based interventions
    • Rigatelli G (2005) Expanding the use of intracardiac echocardiography in congenital heart disease catheter-based interventions. J Am Soc Echocardiogr 18:1230-1231
    • (2005) J Am Soc Echocardiogr , vol.18 , pp. 1230-1231
    • Rigatelli, G.1
  • 7
    • 85081444351 scopus 로고    scopus 로고
    • Intracardiac echocardiography guidance in cardiovascular interventions: Different devices for different purposes
    • (in press)
    • Rigatelli G, Hjiazi Z Intracardiac echocardiography guidance in cardiovascular interventions: Different devices for different purposes. J Invas Cardiol (in press)
    • J Invas Cardiol
    • Rigatelli, G.1    Hjiazi, Z.2
  • 8
    • 0036672811 scopus 로고    scopus 로고
    • Intracardiac echocardiography during catheter-based procedures: Ultrasound system, examination technique, and image presentation
    • Zanchetta M, Rigatelli G, Pedon L, Zennaro M, Onorato E, Maiolino P (2002) Intracardiac echocardiography during catheter-based procedures: ultrasound system, examination technique, and image presentation. Echocardiography 19:501-507
    • (2002) Echocardiography , vol.19 , pp. 501-507
    • Zanchetta, M.1    Rigatelli, G.2    Pedon, L.3    Zennaro, M.4    Onorato, E.5    Maiolino, P.6
  • 9
    • 0242720939 scopus 로고    scopus 로고
    • Intracardiac echocardiography-guided transcatheter closure of secundum atrial septal defect: A new efficient device selection method
    • Zanchetta M, Onorato E, Rigatelli G, Pedon L, Zennaro M, Maiolino P (2003) Intracardiac echocardiography-guided transcatheter closure of secundum atrial septal defect: A new efficient device selection method. J Am Coll Cardiol 42:1677-1682
    • (2003) J Am Coll Cardiol , vol.42 , pp. 1677-1682
    • Zanchetta, M.1    Onorato, E.2    Rigatelli, G.3    Pedon, L.4    Zennaro, M.5    Maiolino, P.6
  • 12
    • 27744527721 scopus 로고    scopus 로고
    • Radiation exposure in stent-grafting of abdominal aortic aneurysms
    • Geijer H, Larzon T, Popek R, Beckman KW (2005) Radiation exposure in stent-grafting of abdominal aortic aneurysms. Br J Radiol 78:906-912
    • (2005) Br J Radiol , vol.78 , pp. 906-912
    • Geijer, H.1    Larzon, T.2    Popek, R.3    Beckman, K.W.4
  • 15
    • 0017863110 scopus 로고
    • Measurement of atrial septal defect during cardiac catheterization. Experimental and clinical results
    • King TD, Thompson SL, Mills NL (1978) Measurement of atrial septal defect during cardiac catheterization. Experimental and clinical results. Am J Cardiol 41:537-542
    • (1978) Am J Cardiol , vol.41 , pp. 537-542
    • King, T.D.1    Thompson, S.L.2    Mills, N.L.3
  • 16
    • 0025797609 scopus 로고
    • Relationship of echocardiographic, shunt flow, and angiographic size to the stretched diameter of the atrial septal defect
    • Rao PS, Langhough R (1991) Relationship of echocardiographic, shunt flow, and angiographic size to the stretched diameter of the atrial septal defect. Am Heart J 122:505-508
    • (1991) Am Heart J , vol.122 , pp. 505-508
    • Rao, P.S.1    Langhough, R.2
  • 17
    • 0027494271 scopus 로고
    • Two-dimensional echocardiographic and color Doppler measurements of atrial septal defect, and comparison with the balloon-stretched diameter
    • Godart F, Rey C, Francart C, et al (1993) Two-dimensional echocardiographic and color Doppler measurements of atrial septal defect, and comparison with the balloon-stretched diameter. Am J Cardiol 72:1095-1097
    • (1993) Am J Cardiol , vol.72 , pp. 1095-1097
    • Godart, F.1    Rey, C.2    Francart, C.3
  • 18
    • 0025276752 scopus 로고
    • Transesophageal echocardiographic guidance of transcatheter closure of atrial septal defect
    • Hellebrand WE, Fahey JT, Mc Gowan FX, et al (1990) Transesophageal echocardiographic guidance of transcatheter closure of atrial septal defect. Am J Cardiol 66:207-213
    • (1990) Am J Cardiol , vol.66 , pp. 207-213
    • Hellebrand, W.E.1    Fahey, J.T.2    Mc Gowan, F.X.3
  • 19
    • 0027284977 scopus 로고
    • Biplane transesophageal echo-Doppler studies of atrial septal defects: Quantitative evaluation and monitoring for transcatheter closure
    • Ishii M, Kato H, Inoue O, et al (1993) Biplane transesophageal echo-Doppler studies of atrial septal defects: Quantitative evaluation and monitoring for transcatheter closure. Am Heart J 125:1363-1375
    • (1993) Am Heart J , vol.125 , pp. 1363-1375
    • Ishii, M.1    Kato, H.2    Inoue, O.3
  • 20
    • 0035143017 scopus 로고    scopus 로고
    • Transcatheter closure of atrial septal defects and patent foramen ovale under intracardiac echocardiographic guidance: Feasibility and comparison with transesophageal echocardiography
    • Hijazi Z, Wang Z, Cao Q, Koenig P, Waight D, Lang R (2001) Transcatheter closure of atrial septal defects and patent foramen ovale under intracardiac echocardiographic guidance: Feasibility and comparison with transesophageal echocardiography. Catheter Cardiovasc Interv 52:194-199
    • (2001) Catheter Cardiovasc Interv , vol.52 , pp. 194-199
    • Hijazi, Z.1    Wang, Z.2    Cao, Q.3    Koenig, P.4    Waight, D.5    Lang, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.