메뉴 건너뛰기




Volumn 122, Issue 2, 2007, Pages 395-402

Optimizing the ratio of horseradish peroxidase and glucose oxidase on a bienzyme electrode: Comparison of a theoretical and experimental approach

Author keywords

Biosensor; Horseradish peroxidase glucose oxidase electrode; Mathematical and computational modelling; Michaelis Menten kinetics

Indexed keywords

BOUNDARY CONDITIONS; COMPUTER SIMULATION; ELECTRODES; ENZYME KINETICS; MATHEMATICAL MODELS; NUMERICAL METHODS; PARTIAL DIFFERENTIAL EQUATIONS;

EID: 33947167814     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2006.06.006     Document Type: Article
Times cited : (43)

References (8)
  • 4
    • 21544481063 scopus 로고    scopus 로고
    • Enzyme biosensors based on electron transfer between electrode and immobilized peroxidases
    • Mulchandani A., and Rogers K.R. (Eds), Humana Press, Totowa, NJ
    • Gorton L., Csöregi E., Ruzgas T., Gazaryan I., and Marko-Varga G. Enzyme biosensors based on electron transfer between electrode and immobilized peroxidases. In: Mulchandani A., and Rogers K.R. (Eds). Enzyme and Microbial Biosensors. Techniques and Protocols vol. 6 (1998), Humana Press, Totowa, NJ 93-120
    • (1998) Enzyme and Microbial Biosensors. Techniques and Protocols , vol.6 , pp. 93-120
    • Gorton, L.1    Csöregi, E.2    Ruzgas, T.3    Gazaryan, I.4    Marko-Varga, G.5
  • 5
    • 0032746224 scopus 로고    scopus 로고
    • Development of an electrochemical flow-injection immunoassay (FIIA) for the real-time monitoring of biospecific interactions
    • Killard A.J., Zhang S., Zhao H., John R., Iwuoha E.I., and Smyth M.R. Development of an electrochemical flow-injection immunoassay (FIIA) for the real-time monitoring of biospecific interactions. Anal. Chim. Acta 400 (1999) 109-119
    • (1999) Anal. Chim. Acta , vol.400 , pp. 109-119
    • Killard, A.J.1    Zhang, S.2    Zhao, H.3    John, R.4    Iwuoha, E.I.5    Smyth, M.R.6
  • 6
    • 0001676625 scopus 로고    scopus 로고
    • Reactivities of organic phase biosensors. 1. Enhancement of the sensitivity and stability of am-perometric peroxidase biosensors using chemically modified enzymes
    • Iwuoha E.I., Leister I., Miland E., Smyth M.R., and Fágáin C.O. Reactivities of organic phase biosensors. 1. Enhancement of the sensitivity and stability of am-perometric peroxidase biosensors using chemically modified enzymes. Anal. Chem. 69 (1997) 1674-1681
    • (1997) Anal. Chem. , vol.69 , pp. 1674-1681
    • Iwuoha, E.I.1    Leister, I.2    Miland, E.3    Smyth, M.R.4    Fágáin, C.O.5
  • 7
    • 0031440098 scopus 로고    scopus 로고
    • Reactivities of organic phase biosensors. 2. The amperometric behaviour of horseradish peroxidase immobilised on a platinum electrode modified with an electrosynthetic polyaniline film
    • Iwuoha E.I., Leister I., Miland E., Smyth M.R., and Fágáin C.O. Reactivities of organic phase biosensors. 2. The amperometric behaviour of horseradish peroxidase immobilised on a platinum electrode modified with an electrosynthetic polyaniline film. Bios. Biolectron. 12 (1997) 749-761
    • (1997) Bios. Biolectron. , vol.12 , pp. 749-761
    • Iwuoha, E.I.1    Leister, I.2    Miland, E.3    Smyth, M.R.4    Fágáin, C.O.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.