메뉴 건너뛰기




Volumn 120, Issue 4, 2007, Pages 336-338

Effect of fiberoptic bronchoscope compared with direct laryngoscope on hemodynamic responses to orotracheal intubation

Author keywords

Fiberoptic bronchoscope; General anesthesia; Hemodynamic responses; Orotracheal intubation

Indexed keywords

FENTANYL; ISOFLURANE; MIDAZOLAM; NITROUS OXIDE; OXYGEN; PROPOFOL; SCOPOLAMINE; VECURONIUM;

EID: 33947154697     PISSN: 03666999     EISSN: None     Source Type: Journal    
DOI: 10.1097/00029330-200702020-00015     Document Type: Article
Times cited : (12)

References (13)
  • 1
    • 0003743609 scopus 로고    scopus 로고
    • Fiberoptic endoscopy and the difficult airway
    • New York: Raven Press
    • Ovassapian A. Fiberoptic endoscopy and the difficult airway. New York: Raven Press; 1996: 157-201.
    • (1996) , pp. 157-201
    • Ovassapian, A.1
  • 2
    • 33646530807 scopus 로고    scopus 로고
    • The adverse physiologic responses to intubation and its prevention
    • In: Xue FS, ed. Zhengzhou, China: Zhengzhou University Publishing House
    • Li P, He N, Xue FS. The adverse physiologic responses to intubation and its prevention. In: Xue FS, ed. Modern airway management - critical procedure for anesthesia and intensive care. Zhengzhou, China: Zhengzhou University Publishing House; 2002: 1020-1230.
    • (2002) Modern Airway Management - Critical Procedure for Anesthesia and Intensive Care , pp. 1020-1230
    • Li, P.1    He, N.2    Xue, F.S.3
  • 3
    • 0026502542 scopus 로고
    • Attenuating the hypertensive response to laryngoscopy and endotracheal intubation using awake fiberoptic intubation
    • Hawkyard SJ, Morrison A, Doyle LA, Croton RS, Wake PN. Attenuating the hypertensive response to laryngoscopy and endotracheal intubation using awake fiberoptic intubation. Acta Anaesthesiol Scand 1992; 36: 1-4
    • (1992) Acta Anaesthesiol Scand , vol.36 , pp. 1-4
    • Hawkyard, S.J.1    Morrison, A.2    Doyle, L.A.3    Croton, R.S.4    Wake, P.N.5
  • 4
    • 33646514660 scopus 로고    scopus 로고
    • Comparison of haemodynamic responses to orotracheal intubation with glidescope(R) videolaryngoscope and fibreoptic bronchoscope
    • Xue FS, Zhang GH, Li XY, Sun HT, Li P, Sun HY, et al. Comparison of haemodynamic responses to orotracheal intubation with glidescope(R) videolaryngoscope and fibreoptic bronchoscope. Eur J Anaesthesiol 2006; 23: 522-526.
    • (2006) Eur J Anaesthesiol , vol.23 , pp. 522-526
    • Xue, F.S.1    Zhang, G.H.2    Li, X.Y.3    Sun, H.T.4    Li, P.5    Sun, H.Y.6
  • 5
    • 0034538476 scopus 로고    scopus 로고
    • Evaluation of the cardiovascular responses to fiberoptic orotracheal intubation with television monitoring: Comparison with conventional direct laryngoscopy
    • Adachi YU, Takamatsu I, Watanabe K, Uchihashi Y, Higuchi H, Satoh T. Evaluation of the cardiovascular responses to fiberoptic orotracheal intubation with television monitoring: comparison with conventional direct laryngoscopy. J Clin Anesth 2000; 12: 503-508.
    • (2000) J Clin Anesth , vol.12 , pp. 503-508
    • Adachi, Y.U.1    Takamatsu, I.2    Watanabe, K.3    Uchihashi, Y.4    Higuchi, H.5    Satoh, T.6
  • 6
    • 0035145238 scopus 로고    scopus 로고
    • Attenuation of haemodynamic responses to tracheal intubation by the styletscope
    • Kitamura T, Yamada Y, Chinzei M, Du HL, Hanaoka K. Attenuation of haemodynamic responses to tracheal intubation by the styletscope. Br J Anaesth 2001; 86: 275-277.
    • (2001) Br J Anaesth , vol.86 , pp. 275-277
    • Kitamura, T.1    Yamada, Y.2    Chinzei, M.3    Du, H.L.4    Hanaoka, K.5
  • 7
    • 0034935553 scopus 로고    scopus 로고
    • Comparison of the lightwand technique with direct laryngoscopy for awake endotracheal intubation in emergency cases
    • Nishikawa K, Kawana S, Namiki A. Comparison of the lightwand technique with direct laryngoscopy for awake endotracheal intubation in emergency cases. J Clin Anesth 2001; 13: 259-263.
    • (2001) J Clin Anesth , vol.13 , pp. 259-263
    • Nishikawa, K.1    Kawana, S.2    Namiki, A.3
  • 8
    • 0034020252 scopus 로고    scopus 로고
    • A comparison of hemodynamic changes after endotracheal intubation by using the lightwand device and the laryngoscope in normotensive and hypertensive patients
    • Nishikawa K, Omote K, Kawana S, Namiki A. A comparison of hemodynamic changes after endotracheal intubation by using the lightwand device and the laryngoscope in normotensive and hypertensive patients. Anesth Analg 2000; 90: 1203-1207.
    • (2000) Anesth Analg , vol.90 , pp. 1203-1207
    • Nishikawa, K.1    Omote, K.2    Kawana, S.3    Namiki, A.4
  • 9
    • 0035216643 scopus 로고    scopus 로고
    • Use of the fibreoptic stylet scope (Styletscope) reduces the hemodynamic response to intubation in normotensive and hypertensive patients
    • Kimura A, Yamakage M, Chen X, Kamada Y, Namiki A. Use of the fibreoptic stylet scope (Styletscope) reduces the hemodynamic response to intubation in normotensive and hypertensive patients. Can J Anaesth 2001; 48: 919-923.
    • (2001) Can J Anaesth , vol.48 , pp. 919-923
    • Kimura, A.1    Yamakage, M.2    Chen, X.3    Kamada, Y.4    Namiki, A.5
  • 10
    • 0017725120 scopus 로고
    • Circulatory changes during direct laryngoscopy and tracheal intubation: Influence of duration of laryngoscopy with or without prior lidocaine
    • Stoelting RK. Circulatory changes during direct laryngoscopy and tracheal intubation: influence of duration of laryngoscopy with or without prior lidocaine. Anesthesiology 1977; 47: 381-384.
    • (1977) Anesthesiology , vol.47 , pp. 381-384
    • Stoelting, R.K.1
  • 11
    • 0026542026 scopus 로고
    • When the endotracheal tube will not pass over the flexible fiberoptic bronchonchoscope
    • Katsnelson T, Frost EA, Farcon E, Goldinger PL. When the endotracheal tube will not pass over the flexible fiberoptic bronchonchoscope. Anesthesiology 1992; 76: 151-152.
    • (1992) Anesthesiology , vol.76 , pp. 151-152
    • Katsnelson, T.1    Frost, E.A.2    Farcon, E.3    Goldinger, P.L.4
  • 12
    • 0023150275 scopus 로고
    • Cardiovascular and catecholamine responses to laryngoscopy with and without tracheal intubation
    • Shribman AJ, Smith G, Achola KJ. Cardiovascular and catecholamine responses to laryngoscopy with and without tracheal intubation. Br J Anaesth 1987; 59: 295-299.
    • (1987) Br J Anaesth , vol.59 , pp. 295-299
    • Shribman, A.J.1    Smith, G.2    Achola, K.J.3
  • 13
    • 33745083392 scopus 로고    scopus 로고
    • Comparative study of hemodynamic responses to orotra-cheal intubation with intubating laryngeal mask airway
    • Zhang GH, Xue FS, Sun HY, Li CW, Sun HT, Li P, et al. Comparative study of hemodynamic responses to orotra-cheal intubation with intubating laryngeal mask airway. Chin Med J 2006; 119: 899-904.
    • (2006) Chin Med J , vol.119 , pp. 899-904
    • Zhang, G.H.1    Xue, F.S.2    Sun, H.Y.3    Li, C.W.4    Sun, H.T.5    Li, P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.