메뉴 건너뛰기




Volumn 35, Issue 3, 2007, Pages 986-

Silver-coated endotracheal tubes: Is the bactericidal effect time limited? [9]

Author keywords

[No Author keywords available]

Indexed keywords

SILVER;

EID: 33947147337     PISSN: 00903493     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.CCM.0000257477.44926.90     Document Type: Letter
Times cited : (2)

References (7)
  • 1
    • 0004946462 scopus 로고    scopus 로고
    • Implications of endotracheal tube biofilm for ventilator-associated pneumonia
    • Adair CG, Gorman SP, Feron BM, et al: Implications of endotracheal tube biofilm for ventilator-associated pneumonia. Intensive Care Med 1999; 25:1072-1076
    • (1999) Intensive Care Med , vol.25 , pp. 1072-1076
    • Adair, C.G.1    Gorman, S.P.2    Feron, B.M.3
  • 2
    • 33750267926 scopus 로고    scopus 로고
    • Reduced burden of bacterial airway colonization with a novel silver-coated endotracheal tube in a randomized multiple-center feasibility study
    • Rello J, Kollef M, Diaz E, et al: Reduced burden of bacterial airway colonization with a novel silver-coated endotracheal tube in a randomized multiple-center feasibility study. Crit Care Med 2006; 34:2766-2772
    • (2006) Crit Care Med , vol.34 , pp. 2766-2772
    • Rello, J.1    Kollef, M.2    Diaz, E.3
  • 3
    • 0036202242 scopus 로고    scopus 로고
    • Silver-coated endotracheal tubes associated with reduced bacterial burden in the lungs of mechanically ventilated dogs
    • Olson ME, Harmon BG, Kollef MH: Silver-coated endotracheal tubes associated with reduced bacterial burden in the lungs of mechanically ventilated dogs. Chest 2002; 121:863-870
    • (2002) Chest , vol.121 , pp. 863-870
    • Olson, M.E.1    Harmon, B.G.2    Kollef, M.H.3
  • 4
    • 2542496745 scopus 로고    scopus 로고
    • Endotracheal tubes coated with antiseptics decrease bacterial colonization of the ventilator circuits, lungs, and endotracheal tube
    • Berra L, De Marchi L, Yu ZX, et al: Endotracheal tubes coated with antiseptics decrease bacterial colonization of the ventilator circuits, lungs, and endotracheal tube. Anesthesiology 2004; 100:1446-1456
    • (2004) Anesthesiology , vol.100 , pp. 1446-1456
    • Berra, L.1    De Marchi, L.2    Yu, Z.X.3
  • 5
    • 33947163559 scopus 로고    scopus 로고
    • Evaluation of bactericidal coated tracheal tube on prevention of bacterial colonization
    • Panzeri M, Marelli C, Brambillasca P, et al: Evaluation of bactericidal coated tracheal tube on prevention of bacterial colonization. Intensive Care Med 2005; 31:S78
    • (2005) Intensive Care Med , vol.31
    • Panzeri, M.1    Marelli, C.2    Brambillasca, P.3
  • 6
    • 33646861619 scopus 로고    scopus 로고
    • Antibacterial-coated tracheal tubes cleaned with the Mucus Shaver: A novel method to retain long-term bactericidal activity of coated tracheal tubes
    • Berra L, Curto F, Li Bassi G, et al: Antibacterial-coated tracheal tubes cleaned with the Mucus Shaver: A novel method to retain long-term bactericidal activity of coated tracheal tubes. Intensive Care Med 2006; 32:888-893
    • (2006) Intensive Care Med , vol.32 , pp. 888-893
    • Berra, L.1    Curto, F.2    Li Bassi, G.3
  • 7
    • 17844400830 scopus 로고    scopus 로고
    • Novel system for complete removal of secretions within the endotracheal tube: The Mucus Shaver
    • Kolobow T, Berra L, Li Bassi G, et al: Novel system for complete removal of secretions within the endotracheal tube: The Mucus Shaver. Anesthesiology 2005; 102:1063-1065
    • (2005) Anesthesiology , vol.102 , pp. 1063-1065
    • Kolobow, T.1    Berra, L.2    Li Bassi, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.