메뉴 건너뛰기




Volumn 18, Issue 6, 2006, Pages 284-295

Muscle relaxation controlled by automated administration of cisatracurium

Author keywords

Automatic fuzzy logic control (FLC); Cisatracurium; Delay time; Depth of muscle relaxation (DOM); Intensive manual control; Intermitted bolus control

Indexed keywords

BIOMECHANICS; DRUG PRODUCTS; FUZZY LOGIC; INTENSIVE CARE UNITS; OPERATING ROOMS; PATIENT MONITORING; SURGERY; TIME DELAY;

EID: 33847746286     PISSN: 10162372     EISSN: None     Source Type: Journal    
DOI: 10.4015/S1016237206000439     Document Type: Article
Times cited : (5)

References (37)
  • 1
    • 0017235077 scopus 로고
    • Computer-controlled muscle relaxation: A comparison of four muscle relaxants in sheep
    • N.M. Cass, D.G. Lampard, W.A. Brown, J.R. Coles : Computer-controlled muscle relaxation: a comparison of four muscle relaxants in sheep. Anaesthesia Intensive Care 1976; 4: 16-22.
    • (1976) Anaesthesia Intensive Care , vol.4 , pp. 16-22
    • Cass, N.M.1    Lampard, D.G.2    Brown, W.A.3    Coles, J.R.4
  • 3
    • 0034425117 scopus 로고    scopus 로고
    • Hierarchical rule-based monitoring and fuzzy logic control for neuromuscular block
    • J.S. Shieh, S.Z. Fan, L.W. Chang, C.C. Liu : Hierarchical rule-based monitoring and fuzzy logic control for neuromuscular block. Clinical Monitoring and Computing 2000; 16: 583-592.
    • (2000) Clinical Monitoring and Computing , vol.16 , pp. 583-592
    • Shieh, J.S.1    Fan, S.Z.2    Chang, L.W.3    Liu, C.C.4
  • 4
    • 0030023953 scopus 로고    scopus 로고
    • Performance assessment of a fuzzy controller for atracurium-induced neuromuscular block
    • D.G. Mason, N.D. Edwards, D.A. Linkens, C.S. Reilly : Performance assessment of a fuzzy controller for atracurium-induced neuromuscular block. Brit J Anaesth 1996;76: 396-400.
    • (1996) Brit J Anaesth , vol.76 , pp. 396-400
    • Mason, D.G.1    Edwards, N.D.2    Linkens, D.A.3    Reilly, C.S.4
  • 6
  • 9
    • 0031239474 scopus 로고    scopus 로고
    • Fuzzy logic for model adaptation of a pharmacokinetic-based closed loop delivery system for pancuronium
    • S.E. Kern, J.O. Johnson, D.R. Westenskow : Fuzzy logic for model adaptation of a pharmacokinetic-based closed loop delivery system for pancuronium. Artificial Intelligence in Medicine 1997;11: 9-31.
    • (1997) Artificial Intelligence in Medicine , vol.11 , pp. 9-31
    • Kern, S.E.1    Johnson, J.O.2    Westenskow, D.R.3
  • 11
    • 0025489621 scopus 로고
    • Self-tuning PID control of atracurium-induced muscle relaxation in surgical patients
    • M Denai, DA Linkens, AJ Asbury, AD MacLeod, WM Gray : Self-tuning PID control of atracurium-induced muscle relaxation in surgical patients. IEEE Proceedings 1990; 137: 258-296.
    • (1990) IEEE Proceedings , vol.137 , pp. 258-296
    • Denai, M.1    Linkens, D.A.2    Asbury, A.J.3    MacLeod, A.D.4    Gray, W.M.5
  • 13
    • 0000784190 scopus 로고
    • Closed control of loops with dead times
    • O.H. Smith : Closed control of loops with dead times. Chemical Engineering Program 1957; 53 : 217-219.
    • (1957) Chemical Engineering Program , vol.53 , pp. 217-219
    • Smith, O.H.1
  • 14
    • 0024070450 scopus 로고
    • Exploitation of time delays for improved process control
    • N. Shanmugathasan, R.D. Johnston : Exploitation of time delays for improved process control, Internal Journal of Control 1988; 48 (3): 1137-1162.
    • (1988) Internal Journal of Control , vol.48 , Issue.3 , pp. 1137-1162
    • Shanmugathasan, N.1    Johnston, R.D.2
  • 15
    • 0034479714 scopus 로고    scopus 로고
    • Output feedback robust control of uncertain fuzzy dynamic systems with time-varying delay
    • K.R. Lee, J.H. Kim, E.T. Jeung, H.B. Park : Output feedback robust control of uncertain fuzzy dynamic systems with time-varying delay. IEEE Transactions on Fuzzy Systems 2000; 8 (6): 657-664.
    • (2000) IEEE Transactions on Fuzzy Systems , vol.8 , Issue.6 , pp. 657-664
    • Lee, K.R.1    Kim, J.H.2    Jeung, E.T.3    Park, H.B.4
  • 17
    • 0033204741 scopus 로고    scopus 로고
    • Higher order fuzzy control structure for higher order or time-delay systems
    • H.X. Li, S.K. Tso : Higher order fuzzy control structure for higher order or time-delay systems, IEEE Transactions on Fuzzy Systems 1999; 7 (5): 540-552.
    • (1999) IEEE Transactions on Fuzzy Systems , vol.7 , Issue.5 , pp. 540-552
    • Li, H.X.1    Tso, S.K.2
  • 18
    • 1942436728 scopus 로고    scopus 로고
    • Delay-dependent guaranteed cost control for T-S fuzzy systems with time delays
    • X.P. Guan, C.L. Chen : Delay-dependent guaranteed cost control for T-S fuzzy systems with time delays. IEEE Transactions on Fuzzy Systems 2004; 12 (2): 236-249.
    • (2004) IEEE Transactions on Fuzzy Systems , vol.12 , Issue.2 , pp. 236-249
    • Guan, X.P.1    Chen, C.L.2
  • 19
    • 0033721189 scopus 로고    scopus 로고
    • Analysis and synthesis of nonlinear time-delay systems via fuzzy control approach
    • Y.Y. Cao, P.M. Frank : Analysis and synthesis of nonlinear time-delay systems via fuzzy control approach. IEEE Transactions on Fuzzy Systems 2000; 8 (2): 200-211.
    • (2000) IEEE Transactions on Fuzzy Systems , vol.8 , Issue.2 , pp. 200-211
    • Cao, Y.Y.1    Frank, P.M.2
  • 20
    • 0037911622 scopus 로고    scopus 로고
    • An optimal control method for linear systems with time delay
    • G.P. Cai, J.Z. Huang, S.X. Yang : An optimal control method for linear systems with time delay. Computers and Structures 2003 ; 81: 1539-1546.
    • (2003) Computers and Structures , vol.81 , pp. 1539-1546
    • Cai, G.P.1    Huang, J.Z.2    Yang, S.X.3
  • 21
    • 0000824505 scopus 로고
    • Comparison of equipotent dose of 51W89 and atracurium
    • 3A, A1090
    • J.Y. Lepage and J.M. Malinovsky : Comparison of equipotent dose of 51W89 and atracurium, Anesthesiology 1994; 81 (3A): A1090.
    • (1994) Anesthesiology , pp. 81
    • Lepage, J.Y.1    Malinovsky, J.M.2
  • 22
    • 0032955521 scopus 로고    scopus 로고
    • Clinical pharmacokinetics of cisatracurium bseilate
    • D.F. Kisor and V.D. Schmith : Clinical pharmacokinetics of cisatracurium bseilate. Clinical Pharmacokinetics. 1999; 36(1): 27-40.
    • (1999) Clinical Pharmacokinetics , vol.36 , Issue.1 , pp. 27-40
    • Kisor, D.F.1    Schmith, V.D.2
  • 23
    • 4344606162 scopus 로고    scopus 로고
    • Physicochemical properties of neuromuscular blocking agents and their impact on the pharmacokinetic-pharmacodynamic relationship
    • J.J. Roy and F. Varin : Physicochemical properties of neuromuscular blocking agents and their impact on the pharmacokinetic-pharmacodynamic relationship. Brit J Anaesth 2004 ; 93 (2) : 241-248.
    • (2004) Brit J Anaesth , vol.93 , Issue.2 , pp. 241-248
    • Roy, J.J.1    Varin, F.2
  • 24
    • 0029988636 scopus 로고    scopus 로고
    • Pharmacokinetics and pharmacodynamics of cisatracurium in patients with end-stage liver disease undergoing liver transplantation
    • A.M.D. Wolf, J.A. Freeman, V.L. Scott, W. Tullock, D.A. Smith, D.F. Kisor, S. Kerls, D.R. Cook : Pharmacokinetics and pharmacodynamics of cisatracurium in patients with end-stage liver disease undergoing liver transplantation. Brit J Anaesth 1996;76: 624-628.
    • (1996) Brit J Anaesth , vol.76 , pp. 624-628
    • Wolf, A.M.D.1    Freeman, J.A.2    Scott, V.L.3    Tullock, W.4    Smith, D.A.5    Kisor, D.F.6    Kerls, S.7    Cook, D.R.8
  • 25
    • 0029979425 scopus 로고    scopus 로고
    • Pharmacokinetics and pharmacodynamics of cisatracurium in young and elderly adult patients
    • S. Sorooshian, M. Stafford, N. Eastwood. A. Boyd, C. Hull, P. Wright : Pharmacokinetics and pharmacodynamics of cisatracurium in young and elderly adult patients. Anesthesiology 1996 ; 84 (5) : 1083-1091.
    • (1996) Anesthesiology , vol.84 , Issue.5 , pp. 1083-1091
    • Sorooshian, S.1    Stafford, M.2    Eastwood, N.3    Boyd, A.4    Hull, C.5    Wright, P.6
  • 26
    • 0029916055 scopus 로고    scopus 로고
    • J.Y. Lepage, J.M. Malinovsky. M. Malinge, T. Lechevalier, C. Dupuch, A. Cozian, M. Pinaud, R. : Souron, Pharmacodynamic dose-response and safety study of cisatracurium (51W89) in adult surgical patients during N2O-O2-Opioid anesthesia. Anesthesia and analgesia 1996 ; 83 : 823-829.
    • J.Y. Lepage, J.M. Malinovsky. M. Malinge, T. Lechevalier, C. Dupuch, A. Cozian, M. Pinaud, R. : Souron, Pharmacodynamic dose-response and safety study of cisatracurium (51W89) in adult surgical patients during N2O-O2-Opioid anesthesia. Anesthesia and analgesia 1996 ; 83 : 823-829.
  • 28
    • 0031785114 scopus 로고    scopus 로고
    • Pharmacokinetics and pharmacodynamics of cisatracurium after a short infusion in patients under propofol anesthesia
    • T.V. Tran, P. Fiset, F. Varin : Pharmacokinetics and pharmacodynamics of cisatracurium after a short infusion in patients under propofol anesthesia. Anesthesia and analgesia 1998;87: 1158-63.
    • (1998) Anesthesia and analgesia , vol.87 , pp. 1158-1163
    • Tran, T.V.1    Fiset, P.2    Varin, F.3
  • 29
    • 0028783628 scopus 로고
    • Pharmacokinetics of 1R-cis 1'R-cis atracurium besylate (51W89) and plasma laudanosine concentrations in health and chronic renal failure
    • N.B. Eastwood, A.H. Boyd, C.J.R. Parker. J.M. Hunter : Pharmacokinetics of 1R-cis 1'R-cis atracurium besylate (51W89) and plasma laudanosine concentrations in health and chronic renal failure. Brit J Anaesth 1995; 75 : 431-435.
    • (1995) Brit J Anaesth , vol.75 , pp. 431-435
    • Eastwood, N.B.1    Boyd, A.H.2    Parker, C.J.R.3    Hunter, J.M.4
  • 30
    • 0034299691 scopus 로고    scopus 로고
    • A self-tuning fuzzy PI controller
    • R.K. Mudi, N.R. Pal : A self-tuning fuzzy PI controller. Fuzzy Sets and Systems 2000 : 115 : 327-338.
    • (2000) Fuzzy Sets and Systems , vol.115 , pp. 327-338
    • Mudi, R.K.1    Pal, N.R.2
  • 31
    • 0028287747 scopus 로고
    • The hybrid model: A new pharmacokinetic model for computer-controlled infusion pumps
    • D.R. Wada and D.S. Ward : The hybrid model: a new pharmacokinetic model for computer-controlled infusion pumps. IEEE Transactions on Biomedical Engineering 1994 ; 41 (2) : 134-142.
    • (1994) IEEE Transactions on Biomedical Engineering , vol.41 , Issue.2 , pp. 134-142
    • Wada, D.R.1    Ward, D.S.2
  • 32
    • 0035188779 scopus 로고    scopus 로고
    • Neuro-fuzzy closed-loop control of depth of anaesthesia
    • R. Allen and D. Smith : Neuro-fuzzy closed-loop control of depth of anaesthesia. Artificial Intelligence in Medicine 2001 ; 21 : 185-191.
    • (2001) Artificial Intelligence in Medicine , vol.21 , pp. 185-191
    • Allen, R.1    Smith, D.2
  • 33
    • 0003043428 scopus 로고    scopus 로고
    • J.S. Shieh, D.A. Linkens, J.E.: Peacock, Hierarchical rule-based and self-organizing fuzzy logic control for depth of anaesthesia. IEEE Transactions on Systems, Man, and Cybernetics - Part C: Applications and Reviews 1999 ; 29 (1): 98-109.
    • J.S. Shieh, D.A. Linkens, J.E.: Peacock, Hierarchical rule-based and self-organizing fuzzy logic control for depth of anaesthesia. IEEE Transactions on Systems, Man, and Cybernetics - Part C: Applications and Reviews 1999 ; 29 (1): 98-109.
  • 34
    • 0002714130 scopus 로고    scopus 로고
    • Fuzzy logic for auditory evoke response monitoring and control of depth of anaesthesia
    • M. Elkfafi, J.S. Shieh, D.A. Linkens, J.E. Peacock : Fuzzy logic for auditory evoke response monitoring and control of depth of anaesthesia. Fuzzy Sets and Systems 1998 ; 100 : 29-43.
    • (1998) Fuzzy Sets and Systems , vol.100 , pp. 29-43
    • Elkfafi, M.1    Shieh, J.S.2    Linkens, D.A.3    Peacock, J.E.4
  • 35
    • 0026895556 scopus 로고
    • Self-adaptive and self-organising control applied to nonlinear multivariable anaesthesia: A comparative model-based study
    • D.A. Linkens, M. Mahfour, M. Abbod : Self-adaptive and self-organising control applied to nonlinear multivariable anaesthesia: a comparative model-based study. IEE Proceedings-D 1992 ;139 (4) : 381-394.
    • (1992) IEE Proceedings-D , vol.139 , Issue.4 , pp. 381-394
    • Linkens, D.A.1    Mahfour, M.2    Abbod, M.3
  • 37
    • 1442308365 scopus 로고    scopus 로고
    • M.M.R.F. Struys, TD. Smet, S. Greenwald, A.R. Absalom, S. Binge, E.P. : Mortier, Performance evaluation of two published closed-loop control systems using bispectral index monitoring. Anesthesiology 2004 ; 100 : 640-647.
    • M.M.R.F. Struys, TD. Smet, S. Greenwald, A.R. Absalom, S. Binge, E.P. : Mortier, Performance evaluation of two published closed-loop control systems using bispectral index monitoring. Anesthesiology 2004 ; 100 : 640-647.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.