-
1
-
-
0029907308
-
High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis
-
Østergaard L. Weisskoff RM, Chesler DA, Gyldensted C, Rosen BR. High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis. Magn Reson Med 1996;36:715-725.
-
(1996)
Magn Reson Med
, vol.36
, pp. 715-725
-
-
Østergaard, L.1
Weisskoff, R.M.2
Chesler, D.A.3
Gyldensted, C.4
Rosen, B.R.5
-
2
-
-
0033812331
-
Delay and dispersion effects in dynamic susceptibility contrast MRI: Simulations using singular value decomposition
-
Calamante F, Gadian DG, Connelly A. Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition. Magn Reson Med 2000;44:466-473.
-
(2000)
Magn Reson Med
, vol.44
, pp. 466-473
-
-
Calamante, F.1
Gadian, D.G.2
Connelly, A.3
-
3
-
-
0042739012
-
Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics
-
Calamante F, Yim PJ, Cebral JR. Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics. Neuroimage 2003;19:341-353.
-
(2003)
Neuroimage
, vol.19
, pp. 341-353
-
-
Calamante, F.1
Yim, P.J.2
Cebral, J.R.3
-
4
-
-
28444462867
-
Bolus dispersion issues related to the quantification of perfusion MRI data
-
Calamante F. Bolus dispersion issues related to the quantification of perfusion MRI data. J Magn Reson Imaging 2005;22:718-722.
-
(2005)
J Magn Reson Imaging
, vol.22
, pp. 718-722
-
-
Calamante, F.1
-
5
-
-
0141617505
-
Effects of tracer arrival time on flow estimates in MR perfusion-weightecl imaging
-
Wu O, Østergaard L, Koroshetz WJ, et al. Effects of tracer arrival time on flow estimates in MR perfusion-weightecl imaging. Magn Reson Med 2003;50:856-864.
-
(2003)
Magn Reson Med
, vol.50
, pp. 856-864
-
-
Wu, O.1
Østergaard, L.2
Koroshetz, W.J.3
-
6
-
-
1542346897
-
Removing the effect of SVD algorithmic artefacts present in quantitative MR perfusion studies
-
Smith MR, Lu H, Trochet S, Frayne R. Removing the effect of SVD algorithmic artefacts present in quantitative MR perfusion studies. Magn Reson Med 2004;51:631-634.
-
(2004)
Magn Reson Med
, vol.51
, pp. 631-634
-
-
Smith, M.R.1
Lu, H.2
Trochet, S.3
Frayne, R.4
-
7
-
-
14644402442
-
Tracer delay correction of cerebral blood flow with dynamic susceptibility contrast-enhanced MRI
-
Ibaraki M, Shimosegawa E, Toyoshima H, Takahashi K, Miura S, Kanno I. Tracer delay correction of cerebral blood flow with dynamic susceptibility contrast-enhanced MRI. J Cereb Blood Flow Metab 2005;25:378-390.
-
(2005)
J Cereb Blood Flow Metab
, vol.25
, pp. 378-390
-
-
Ibaraki, M.1
Shimosegawa, E.2
Toyoshima, H.3
Takahashi, K.4
Miura, S.5
Kanno, I.6
-
8
-
-
16444370788
-
An Alternative viewpoint of the similarities and differences of SVD and FT deconvolution algorithms used for quantitative MR perfusion studies
-
Salluzzi M, Frayne R, Smith MR. An Alternative viewpoint of the similarities and differences of SVD and FT deconvolution algorithms used for quantitative MR perfusion studies. Mag Reson Imaging 2005;23:481-492.
-
(2005)
Mag Reson Imaging
, vol.23
, pp. 481-492
-
-
Salluzzi, M.1
Frayne, R.2
Smith, M.R.3
-
9
-
-
32544434091
-
-
Salluzzi M, Frayne R, Smith MR. is correction necessary when clinically determining quantitative cerebral perfusion parameters from multi-slice dynamic susceptibility contrast MR studies? Phys Med Biol 2006;51:407-424.
-
Salluzzi M, Frayne R, Smith MR. is correction necessary when clinically determining quantitative cerebral perfusion parameters from multi-slice dynamic susceptibility contrast MR studies? Phys Med Biol 2006;51:407-424.
-
-
-
|