메뉴 건너뛰기




Volumn 25, Issue 3, 2007, Pages 639-643

Reexamining the quantification of perfusion MRI data in the presence of bolus dispersion

Author keywords

Arterial input function; Bolus tracking; Cerebral blood flow quantification; Dispersion; Perfusion

Indexed keywords

ACCURACY; ALGORITHM; ARTERY OCCLUSION; ARTICLE; BRAIN BLOOD FLOW; CALCULATION; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; QUANTITATIVE DIAGNOSIS; SIMULATION; SYSTEMATIC ERROR;

EID: 33847658710     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.20781     Document Type: Article
Times cited : (20)

References (9)
  • 1
    • 0029907308 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis
    • Østergaard L. Weisskoff RM, Chesler DA, Gyldensted C, Rosen BR. High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis. Magn Reson Med 1996;36:715-725.
    • (1996) Magn Reson Med , vol.36 , pp. 715-725
    • Østergaard, L.1    Weisskoff, R.M.2    Chesler, D.A.3    Gyldensted, C.4    Rosen, B.R.5
  • 2
    • 0033812331 scopus 로고    scopus 로고
    • Delay and dispersion effects in dynamic susceptibility contrast MRI: Simulations using singular value decomposition
    • Calamante F, Gadian DG, Connelly A. Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition. Magn Reson Med 2000;44:466-473.
    • (2000) Magn Reson Med , vol.44 , pp. 466-473
    • Calamante, F.1    Gadian, D.G.2    Connelly, A.3
  • 3
    • 0042739012 scopus 로고    scopus 로고
    • Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics
    • Calamante F, Yim PJ, Cebral JR. Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics. Neuroimage 2003;19:341-353.
    • (2003) Neuroimage , vol.19 , pp. 341-353
    • Calamante, F.1    Yim, P.J.2    Cebral, J.R.3
  • 4
    • 28444462867 scopus 로고    scopus 로고
    • Bolus dispersion issues related to the quantification of perfusion MRI data
    • Calamante F. Bolus dispersion issues related to the quantification of perfusion MRI data. J Magn Reson Imaging 2005;22:718-722.
    • (2005) J Magn Reson Imaging , vol.22 , pp. 718-722
    • Calamante, F.1
  • 5
    • 0141617505 scopus 로고    scopus 로고
    • Effects of tracer arrival time on flow estimates in MR perfusion-weightecl imaging
    • Wu O, Østergaard L, Koroshetz WJ, et al. Effects of tracer arrival time on flow estimates in MR perfusion-weightecl imaging. Magn Reson Med 2003;50:856-864.
    • (2003) Magn Reson Med , vol.50 , pp. 856-864
    • Wu, O.1    Østergaard, L.2    Koroshetz, W.J.3
  • 6
    • 1542346897 scopus 로고    scopus 로고
    • Removing the effect of SVD algorithmic artefacts present in quantitative MR perfusion studies
    • Smith MR, Lu H, Trochet S, Frayne R. Removing the effect of SVD algorithmic artefacts present in quantitative MR perfusion studies. Magn Reson Med 2004;51:631-634.
    • (2004) Magn Reson Med , vol.51 , pp. 631-634
    • Smith, M.R.1    Lu, H.2    Trochet, S.3    Frayne, R.4
  • 8
    • 16444370788 scopus 로고    scopus 로고
    • An Alternative viewpoint of the similarities and differences of SVD and FT deconvolution algorithms used for quantitative MR perfusion studies
    • Salluzzi M, Frayne R, Smith MR. An Alternative viewpoint of the similarities and differences of SVD and FT deconvolution algorithms used for quantitative MR perfusion studies. Mag Reson Imaging 2005;23:481-492.
    • (2005) Mag Reson Imaging , vol.23 , pp. 481-492
    • Salluzzi, M.1    Frayne, R.2    Smith, M.R.3
  • 9
    • 32544434091 scopus 로고    scopus 로고
    • Salluzzi M, Frayne R, Smith MR. is correction necessary when clinically determining quantitative cerebral perfusion parameters from multi-slice dynamic susceptibility contrast MR studies? Phys Med Biol 2006;51:407-424.
    • Salluzzi M, Frayne R, Smith MR. is correction necessary when clinically determining quantitative cerebral perfusion parameters from multi-slice dynamic susceptibility contrast MR studies? Phys Med Biol 2006;51:407-424.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.