메뉴 건너뛰기




Volumn 45, Issue 3, 2000, Pages 729-733

An efficient method of measuring the 4 mm helmet output factor for the Gamma Knife

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; COLLIMATOR; DIODE; DOSIMETRY; GAMMA RADIATION; PRIORITY JOURNAL; RADIATION DOSE; RADIOSURGERY; SYSTEM ANALYSIS; TRIGEMINUS NEURALGIA; X RAY FILM;

EID: 0034021168     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/45/3/311     Document Type: Article
Times cited : (23)

References (13)
  • 1
    • 0031441806 scopus 로고    scopus 로고
    • Stereotactic radiosurgery and radiotherapy: New developments and new directions
    • Benjamin W C, Curran W J Jr, Shrieve D C and Loeffler J S 1997 Stereotactic radiosurgery and radiotherapy: new developments and new directions Semin. Oncol. 24 707-14
    • (1997) Semin. Oncol. , vol.24 , pp. 707-714
    • Benjamin, W.C.1    Curran W.J., Jr.2    Shrieve, D.C.3    Loeffler, J.S.4
  • 2
    • 0023138959 scopus 로고
    • PRESTA: The parameter reduced electron-step transport algorithm
    • Bielajew A F and Rogers D W O 1987 PRESTA: the parameter reduced electron-step transport algorithm Nucl. Instrum. Methods B 18 165-81
    • (1987) Nucl. Instrum. Methods B , vol.18 , pp. 165-181
    • Bielajew, A.F.1    Rogers, D.W.O.2
  • 3
    • 0029872899 scopus 로고    scopus 로고
    • Use of micro-ionization chamber and an anthropomorphic head phantom in a quality assurance program for stereotactic radiosurgery
    • Duggan D M and Coffey C W 1996 Use of micro-ionization chamber and an anthropomorphic head phantom in a quality assurance program for stereotactic radiosurgery Med. Phys. 23 513-6
    • (1996) Med. Phys. , vol.23 , pp. 513-516
    • Duggan, D.M.1    Coffey, C.W.2
  • 4
    • 0032934217 scopus 로고    scopus 로고
    • Simulation of dose distribution irradiation by the Leksell Gamma Unit
    • Liu X and Zhang C 1999 Simulation of dose distribution irradiation by the Leksell Gamma Unit Phys. Med. Biol. 44 441-5
    • (1999) Phys. Med. Biol. , vol.44 , pp. 441-445
    • Liu, X.1    Zhang, C.2
  • 5
    • 0027471614 scopus 로고
    • Stereotactic radiosurgery: Principles and comparison of treatment methods
    • Luxton G, Petrovich Z, Jozsef G, Nedzi L A and Apuzzo M L 1993 Stereotactic radiosurgery: principles and comparison of treatment methods Neurosurgery 32 241-59
    • (1993) Neurosurgery , vol.32 , pp. 241-259
    • Luxton, G.1    Petrovich, Z.2    Jozsef, G.3    Nedzi, L.A.4    Apuzzo, M.L.5
  • 7
    • 0028218940 scopus 로고
    • The use of a radiochromic detector for the determination of stereotactic radiosurgery dose characteristics
    • McLaughlin W L, Soares C G, Sayeg J A, McCullough E C, Kline R W, Wu A and Maitz A H 1994 The use of a radiochromic detector for the determination of stereotactic radiosurgery dose characteristics Med. Phys. 21 379-88
    • (1994) Med. Phys. , vol.21 , pp. 379-388
    • McLaughlin, W.L.1    Soares, C.G.2    Sayeg, J.A.3    McCullough, E.C.4    Kline, R.W.5    Wu, A.6    Maitz, A.H.7
  • 9
    • 0032436637 scopus 로고    scopus 로고
    • 60Co gamma-ray beams and dosimetry of the Gamma Knife
    • 60Co gamma-ray beams and dosimetry of the Gamma Knife Med. Phys. 25 2347-51
    • (1998) Med. Phys. , vol.25 , pp. 2347-2351
    • Nizin, P.S.1
  • 11
    • 0032518344 scopus 로고    scopus 로고
    • Comparison of radiosurgery treatment modalities based on complication and control probabilities
    • Smith V, Verhey L J and Serago C F 1998 Comparison of radiosurgery treatment modalities based on complication and control probabilities Int. J. Radiat. Oncol. Biol. Phys. 40 507-13
    • (1998) Int. J. Radiat. Oncol. Biol. Phys. , vol.40 , pp. 507-513
    • Smith, V.1    Verhey, L.J.2    Serago, C.F.3
  • 12
    • 0032518343 scopus 로고    scopus 로고
    • Comparison of radiosurgery treatment modalities based on physical dose distributions
    • Verhey L J, Smith V and Serago C F 1998 Comparison of radiosurgery treatment modalities based on physical dose distributions Int. J. Radiat. Oncol. Biol. Phys. 40 497-505
    • (1998) Int. J. Radiat. Oncol. Biol. Phys. , vol.40 , pp. 497-505
    • Verhey, L.J.1    Smith, V.2    Serago, C.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.