메뉴 건너뛰기




Volumn 25, Issue 10, 2003, Pages 825-831

On the secondary stability of coated cementless hip replacement: Parameters that affected interface strength

Author keywords

Asymptotic homogenisation; Bone implant interaction; Cementless hip implant; Friction coefficient; Normal contact stiffness; Secondary stability

Indexed keywords

BONE; FINITE ELEMENT METHOD; FRICTION; IMPLANTS (SURGICAL); STIFFNESS;

EID: 0242543311     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1350-4533(03)00099-7     Document Type: Article
Times cited : (28)

References (27)
  • 1
    • 0242494392 scopus 로고
    • Design factors affecting micromotion of porous-coated and low modulus hip prostheses
    • Ebramzadeh E., McKellop H., et al. Design factors affecting micromotion of porous-coated and low modulus hip prostheses. Trans Orthop Res Soc. 13:1988;351-356.
    • (1988) Trans Orthop Res Soc , vol.13 , pp. 351-356
    • Ebramzadeh, E.1    Mckellop, H.2
  • 2
    • 0019955716 scopus 로고
    • The pathology of failed total joint arthroplasty
    • Mirra J.M., Marder R.A., Amstutz H.C. The pathology of failed total joint arthroplasty. Clin Orthop. 170:1982;175-183.
    • (1982) Clin Orthop , vol.170 , pp. 175-183
    • Mirra, J.M.1    Marder, R.A.2    Amstutz, H.C.3
  • 3
    • 0028926750 scopus 로고
    • Cementless femoral components should be made from cobalt chrome
    • Sotereanos N.G., Engh C.A., et al. Cementless femoral components should be made from cobalt chrome. Clin Orthop. 313:1995;146-153.
    • (1995) Clin Orthop , vol.313 , pp. 146-153
    • Sotereanos, N.G.1    Engh, C.A.2
  • 4
    • 0026457532 scopus 로고
    • Quantification of implant micromotion, strain shielding and bone resorption with porous-coated anatomic medullary locking prosthesis
    • Engh C.A., O'Connor D., et al. Quantification of implant micromotion, strain shielding and bone resorption with porous-coated anatomic medullary locking prosthesis. Clin Orthop. 285:1992;13-29.
    • (1992) Clin Orthop , vol.285 , pp. 13-29
    • Engh, C.A.1    O'connor, D.2
  • 5
    • 0028020496 scopus 로고
    • The nature of the bone-implant interface. The lessons learned from implant retrieval and analysis in man and experimental animal
    • Boss J.H., Shajrawi I., Mendes D.G. The nature of the bone-implant interface. The lessons learned from implant retrieval and analysis in man and experimental animal. Med Prog Technol. 20:(3-4):1994;119-142.
    • (1994) Med Prog Technol , vol.20 , Issue.3-4 , pp. 119-142
    • Boss, J.H.1    Shajrawi, I.2    Mendes, D.G.3
  • 6
    • 0032953310 scopus 로고    scopus 로고
    • Implant fixation by bone ingrowth
    • Kienapfel H., Sprey C., et al. Implant fixation by bone ingrowth. J Arthroplasty. 14:(3):1999;355-368.
    • (1999) J Arthroplasty , vol.14 , Issue.3 , pp. 355-368
    • Kienapfel, H.1    Sprey, C.2
  • 7
    • 0345490858 scopus 로고    scopus 로고
    • Hydroxyapatite-coated femoral stems. Histology and histomorphometry around five components retrieved at post mortem
    • Tonino A.J., Therin M., Doyle C. Hydroxyapatite-coated femoral stems. Histology and histomorphometry around five components retrieved at post mortem. J Bone Joint Surg Br. 81:1999;148-154.
    • (1999) J Bone Joint Surg Br , vol.81 , pp. 148-154
    • Tonino, A.J.1    Therin, M.2    Doyle, C.3
  • 8
    • 0026832935 scopus 로고
    • Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions
    • Søballe K., Hansen E.S., et al. Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions. J Orthop Res. 10:(2):1992;285-299.
    • (1992) J Orthop Res , vol.10 , Issue.2 , pp. 285-299
    • Søballe, K.1    Hansen, E.S.2
  • 9
    • 0027381478 scopus 로고
    • Hydroxyapatite ceramic coating for bone implant fixation
    • Søballe K. Hydroxyapatite ceramic coating for bone implant fixation. Acta Orthop Scand. 64:(Suppl 155):1993;1-58.
    • (1993) Acta Orthop Scand , vol.64 , Issue.SUPPL. 155 , pp. 1-58
    • Søballe, K.1
  • 10
    • 0027213551 scopus 로고
    • Migration of hydroxyapatite coated femoral prostheses. A Roentgen stereophotogrammetric study
    • Søballe K., Toksvig-Larsen S., et al. Migration of hydroxyapatite coated femoral prostheses. A Roentgen stereophotogrammetric study. J Bone Joint Surg Br. 75:(5):1993;681-687.
    • (1993) J Bone Joint Surg Br , vol.75 , Issue.5 , pp. 681-687
    • Søballe, K.1    Toksvig-Larsen, S.2
  • 11
    • 0027474762 scopus 로고
    • Hydroxyapatite coating converts fibrous tissue to bone around loaded implants
    • Søballe K., Hansen E.S., et al. Hydroxyapatite coating converts fibrous tissue to bone around loaded implants. J Bone Joint Surg Br. 75:(2):1993;270-278.
    • (1993) J Bone Joint Surg Br , vol.75 , Issue.2 , pp. 270-278
    • Søballe, K.1    Hansen, E.S.2
  • 12
    • 0030483180 scopus 로고    scopus 로고
    • Role of different loading conditions on resorption of hydroxyapatite coating evaluated by histomorphometric and stereological methods
    • Overgaard S., Søballe K., et al. Role of different loading conditions on resorption of hydroxyapatite coating evaluated by histomorphometric and stereological methods. J Orthop Res. 14:(6):1996;888-894.
    • (1996) J Orthop Res , vol.14 , Issue.6 , pp. 888-894
    • Overgaard, S.1    Søballe, K.2
  • 13
    • 0032997613 scopus 로고    scopus 로고
    • The relation between surface roughness and interfacial shear strength for bone-anchored implants. A mathematical model
    • Hansson S., Norton M. The relation between surface roughness and interfacial shear strength for bone-anchored implants. A mathematical model. J Biomech. 32:1999;829-836.
    • (1999) J Biomech , vol.32 , pp. 829-836
    • Hansson, S.1    Norton, M.2
  • 15
    • 0040056644 scopus 로고    scopus 로고
    • Homogenization of solutions of the Poisson equation in a domain perforated along a hypersurface, with mixed boundary conditions on the boundary of the cavities
    • Jäger W., Oleinik O.A., Shaposhnikova T.A. Homogenization of solutions of the Poisson equation in a domain perforated along a hypersurface, with mixed boundary conditions on the boundary of the cavities. Trans Moscow Math Soc. 59:1998;135-157.
    • (1998) Trans Moscow Math Soc , vol.59 , pp. 135-157
    • Jäger, W.1    Oleinik, O.A.2    Shaposhnikova, T.A.3
  • 16
    • 25944446444 scopus 로고    scopus 로고
    • On homogenization of solutions of the Poisson equation in a perforated domain with different types of boundary conditions on different cavities
    • Jäger W., Oleinik O.A., Shaposhnikova T.A. On homogenization of solutions of the Poisson equation in a perforated domain with different types of boundary conditions on different cavities. Applicable Anal. 65:1997;205-223.
    • (1997) Applicable Anal , vol.65 , pp. 205-223
    • Jäger, W.1    Oleinik, O.A.2    Shaposhnikova, T.A.3
  • 17
    • 22044458679 scopus 로고    scopus 로고
    • Asymptotic behaviour of a solution to a boundary value problem in a perforated domain with oscillating boundary
    • Belyaev A.G., Piatnitski A.L., Chechkin G.A. Asymptotic behaviour of a solution to a boundary value problem in a perforated domain with oscillating boundary. Sib Math J. 39:(4):1998;621-644.
    • (1998) Sib Math J , vol.39 , Issue.4 , pp. 621-644
    • Belyaev, A.G.1    Piatnitski, A.L.2    Chechkin, G.A.3
  • 20
    • 0000275736 scopus 로고    scopus 로고
    • On the numerical approximation of a frictional contact problem with normal compliance
    • Han W. On the numerical approximation of a frictional contact problem with normal compliance. Numer Funct Anal Optim. 17:(3-4):1996;307-321.
    • (1996) Numer Funct Anal Optim , vol.17 , Issue.3-4 , pp. 307-321
    • Han, W.1
  • 21
    • 21144473666 scopus 로고
    • Homogenization and two-scale convergence
    • Allaire G. Homogenization and two-scale convergence. SIAM J Math Anal. 23:1992;1482-1518.
    • (1992) SIAM J Math Anal , vol.23 , pp. 1482-1518
    • Allaire, G.1
  • 23
    • 3242828407 scopus 로고    scopus 로고
    • Existence results for the static contact problem with Coulomb friction
    • Eck C., Jarusek J. Existence results for the static contact problem with Coulomb friction. Math Models Methods Appl Sci. 8:(3):1998;445-468.
    • (1998) Math Models Methods Appl Sci , vol.8 , Issue.3 , pp. 445-468
    • Eck, C.1    Jarusek, J.2
  • 26
    • 0034761815 scopus 로고    scopus 로고
    • Even a thin layer of soft tissue may compromise the primary stability of cementless hip stems
    • Viceconti M., Monti L., et al. Even a thin layer of soft tissue may compromise the primary stability of cementless hip stems. Clin Biomech. 16:2001;765-775.
    • (2001) Clin Biomech , vol.16 , pp. 765-775
    • Viceconti, M.1    Monti, L.2
  • 27
    • 0027608006 scopus 로고
    • Frictional interface micromotions and anisotropic stress distribution in a femoral total hip component
    • Rubin P.J., Rakotomanana R.L., et al. Frictional interface micromotions and anisotropic stress distribution in a femoral total hip component. J Biomech. 26:(6):1993;725-739.
    • (1993) J Biomech , vol.26 , Issue.6 , pp. 725-739
    • Rubin, P.J.1    Rakotomanana, R.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.