메뉴 건너뛰기




Volumn 30, Issue 3, 1997, Pages 247-256

Effect of electrode positioning on ECG interpretation by computer

Author keywords

Body surface potential mapping; Computer assisted ECG interpretation; Electrocardiography; Precordial electrodes; Variability

Indexed keywords

ARTICLE; COMPUTER ASSISTED DIAGNOSIS; COMPUTER PROGRAM; DISEASE CLASSIFICATION; ELECTROCARDIOGRAM; ELECTRODE; HEART INFARCTION; HEART LEFT VENTRICLE HYPERTROPHY; HUMAN; HUMAN CELL; HUMAN TISSUE; INTERMETHOD COMPARISON; OBSERVER VARIATION; PRIORITY JOURNAL; SIGNAL PROCESSING;

EID: 0030863644     PISSN: 00220736     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0022-0736(97)80010-6     Document Type: Article
Times cited : (33)

References (26)
  • 1
    • 0029776044 scopus 로고    scopus 로고
    • Variability of precordial electrodes placement during routine electrocardiography
    • Wenger W, Kligfield P: Variability of precordial electrodes placement during routine electrocardiography. J Electrocardiol 29:179, 1996
    • (1996) J Electrocardiol , vol.29 , pp. 179
    • Wenger, W.1    Kligfield, P.2
  • 2
    • 0023627613 scopus 로고
    • Automated serial ECG-analysis within an epidemiological study
    • Michaelis J, Lippold R, Gluck E et al: Automated serial ECG-analysis within an epidemiological study. J Electrocardiol 20 Suppl:34, 1987
    • (1987) J Electrocardiol , vol.20 , Issue.SUPPL. , pp. 34
    • Michaelis, J.1    Lippold, R.2    Gluck, E.3
  • 3
    • 26844455312 scopus 로고
    • Correlation between subjective and objective measures of correspondence between different systems of vectorcardiography
    • Burger HC, Van Brummelen AGW, Van Herpen G: Correlation between subjective and objective measures of correspondence between different systems of vectorcardiography. Am Heart J 67:512, 1964
    • (1964) Am Heart J , vol.67 , pp. 512
    • Burger, H.C.1    Van Brummelen, A.G.W.2    Van Herpen, G.3
  • 4
    • 0015106101 scopus 로고
    • The effect of electrode position on a modified Frank electrovectorcardiographic lead system
    • Gau GT, Smith RE: The effect of electrode position on a modified Frank electrovectorcardiographic lead system. Mayo Clin Proc 46:536, 1971
    • (1971) Mayo Clin Proc , vol.46 , pp. 536
    • Gau, G.T.1    Smith, R.E.2
  • 5
    • 0017875044 scopus 로고
    • Electrode position effects on Frank lead electrocardiograms
    • Berson AS, Haisty WK, Pipberger HV: Electrode position effects on Frank lead electrocardiograms. Am Heart J 95:463, 1978
    • (1978) Am Heart J , vol.95 , pp. 463
    • Berson, A.S.1    Haisty, W.K.2    Pipberger, H.V.3
  • 6
    • 0014275581 scopus 로고
    • Beat to beat and observer variation of the electrocardiogram
    • Fischmann E, Cosma J, Pipberger HV: Beat to beat and observer variation of the electrocardiogram. Am Heart J 75:465, 1968
    • (1968) Am Heart J , vol.75 , pp. 465
    • Fischmann, E.1    Cosma, J.2    Pipberger, H.V.3
  • 7
    • 0017110915 scopus 로고
    • Accuracy and beat-to-beat variation in ECG computer measurements
    • Borovsky D, Zywietz C: Accuracy and beat-to-beat variation in ECG computer measurements. Adv Cardiol 16:176, 1976
    • (1976) Adv Cardiol , vol.16 , pp. 176
    • Borovsky, D.1    Zywietz, C.2
  • 8
    • 0026786338 scopus 로고
    • Variability in ECG computer interpretations: Analysis of individual complexes vs analysis of a representative complex
    • Kors JA, Van Herpen G, Van Bemmel JH: Variability in ECG computer interpretations: analysis of individual complexes vs analysis of a representative complex. J Electrocardiol 25:263, 1992
    • (1992) J Electrocardiol , vol.25 , pp. 263
    • Kors, J.A.1    Van Herpen, G.2    Van Bemmel, J.H.3
  • 9
    • 0023239748 scopus 로고
    • Importance of accurate placement of precordial leads in the 12-lead electrocardiogram
    • Hill NE, Goodman JS: Importance of accurate placement of precordial leads in the 12-lead electrocardiogram. Heart Lung 16:561, 1987
    • (1987) Heart Lung , vol.16 , pp. 561
    • Hill, N.E.1    Goodman, J.S.2
  • 10
    • 0025858633 scopus 로고
    • Variability of electrocardiographic precordial lead placement: A method to improve accuracy and reliability
    • Herman MV, Ingram DA, Levy JA et al: Variability of electrocardiographic precordial lead placement: a method to improve accuracy and reliability. Clin Cardiol 14:469, 1991
    • (1991) Clin Cardiol , vol.14 , pp. 469
    • Herman, M.V.1    Ingram, D.A.2    Levy, J.A.3
  • 11
    • 0027197754 scopus 로고
    • Recognition of electrocardiographic lead misplacements
    • Peberdy MA, Omato JP: Recognition of electrocardiographic lead misplacements. Am J Emerg Med 11:403, 1993
    • (1993) Am J Emerg Med , vol.11 , pp. 403
    • Peberdy, M.A.1    Omato, J.P.2
  • 12
    • 0026580444 scopus 로고
    • Evaluation of changes in standard electrocardiographic QRS waveforms recorded from activity-compatible proximal limb lead positions
    • Pahlm O, Haisty WK, Edenbrandt L et al: Evaluation of changes in standard electrocardiographic QRS waveforms recorded from activity-compatible proximal limb lead positions. Am J Cardiol 69:253, 1992
    • (1992) Am J Cardiol , vol.69 , pp. 253
    • Pahlm, O.1    Haisty, W.K.2    Edenbrandt, L.3
  • 14
    • 0025160665 scopus 로고
    • Common standards for quantitative electrocardiography: Goals and main results
    • Willems JL, Amaud P, Van Bemmel JH et al: Common standards for quantitative electrocardiography: goals and main results. Methods Inf Med 29:263, 1990
    • (1990) Methods Inf Med , vol.29 , pp. 263
    • Willems, J.L.1    Amaud, P.2    Van Bemmel, J.H.3
  • 15
    • 0021964239 scopus 로고
    • Assessment of the performance of electrocardiographic computer programs with the use of a reference data base
    • Willems JL, Arnaud P, Van Bemmel JH et al: Assessment of the performance of electrocardiographic computer programs with the use of a reference data base. Circulation 71:523, 1985
    • (1985) Circulation , vol.71 , pp. 523
    • Willems, J.L.1    Arnaud, P.2    Van Bemmel, J.H.3
  • 16
    • 0026410610 scopus 로고
    • The diagnostic performance of computer programs for the interpretation of electrocardiograms
    • Willems JL, Abreu-Lima C, Arnaud P et al: The diagnostic performance of computer programs for the interpretation of electrocardiograms. N Engl J Med 325:1767, 1991
    • (1991) N Engl J Med , vol.325 , pp. 1767
    • Willems, J.L.1    Abreu-Lima, C.2    Arnaud, P.3
  • 17
    • 0025361546 scopus 로고
    • Stability of computer ECG amplitude measurements in the presence of noise
    • Zywietz C, Willems JL, Arnaud P et al: Stability of computer ECG amplitude measurements in the presence of noise. Comput Biomed Res 23:1990
    • (1990) Comput Biomed Res , vol.23
    • Zywietz, C.1    Willems, J.L.2    Arnaud, P.3
  • 18
    • 0027478540 scopus 로고
    • Body surface potential mapping of ST segment changes in acute myocardial infarction
    • Kornreich F, Montague TJ, Rautaharju PM: Body surface potential mapping of ST segment changes in acute myocardial infarction. Circulation 87:773, 1993
    • (1993) Circulation , vol.87 , pp. 773
    • Kornreich, F.1    Montague, T.J.2    Rautaharju, P.M.3
  • 19
    • 0019504890 scopus 로고
    • Isointegral analysis of body surface maps: Surface distribution and temporal variability in normal subjects
    • Montague TJ, Smith ER, Cameron DA et al: Isointegral analysis of body surface maps: surface distribution and temporal variability in normal subjects. Circulation 63:1166, 1981
    • (1981) Circulation , vol.63 , pp. 1166
    • Montague, T.J.1    Smith, E.R.2    Cameron, D.A.3
  • 20
    • 0022356477 scopus 로고
    • Identification of best electrocardiographic leads for diagnosing myocardial infarction by statistical analysis of body surface potential maps
    • Kornreich F, Rautaharju PM, Warren JW et al: Identification of best electrocardiographic leads for diagnosing myocardial infarction by statistical analysis of body surface potential maps. Am J Cardiol 56:852, 1985
    • (1985) Am J Cardiol , vol.56 , pp. 852
    • Kornreich, F.1    Rautaharju, P.M.2    Warren, J.W.3
  • 22
    • 0014715953 scopus 로고
    • Differences caused by changes in electrode positions in two corrected orthogonal lead systems
    • Berson AS, Gamboa R, Naval A, Pipberger HV: Differences caused by changes in electrode positions in two corrected orthogonal lead systems. J Electrocardiol 3:29, 1970
    • (1970) J Electrocardiol , vol.3 , pp. 29
    • Berson, A.S.1    Gamboa, R.2    Naval, A.3    Pipberger, H.V.4
  • 23
    • 0014147924 scopus 로고
    • Day-to-day variability in the normal electrocardiogram
    • Michaels L, Cadoret RJ: Day-to-day variability in the normal electrocardiogram. Br Heart J 29:913, 1967
    • (1967) Br Heart J , vol.29 , pp. 913
    • Michaels, L.1    Cadoret, R.J.2
  • 24
    • 0015336042 scopus 로고
    • Day-to-day variation of the normal orthogonal electrocardiogram and vectorcardiogram
    • Willems JL, Poblete PF, Pipberger HV: Day-to-day variation of the normal orthogonal electrocardiogram and vectorcardiogram. Circulation 45:1057, 1972
    • (1972) Circulation , vol.45 , pp. 1057
    • Willems, J.L.1    Poblete, P.F.2    Pipberger, H.V.3
  • 25
    • 0021321693 scopus 로고
    • Year-to-year variation of the normal orthogonal electrocardiogram and vectorcardiogram in 243 white males
    • McManus C, Doyle J, Pipberger HV: Year-to-year variation of the normal orthogonal electrocardiogram and vectorcardiogram in 243 white males. J Electrocardiol 17:107, 1984
    • (1984) J Electrocardiol , vol.17 , pp. 107
    • McManus, C.1    Doyle, J.2    Pipberger, H.V.3
  • 26
    • 0025129151 scopus 로고
    • Day-to-day variability of voltage measurements used in electrocardiographic criteria for left ventricular hypertrophy
    • Farb A, Devereux RB, Kligfield P: Day-to-day variability of voltage measurements used in electrocardiographic criteria for left ventricular hypertrophy. J Am Coll Cardiol 15:618, 1990
    • (1990) J Am Coll Cardiol , vol.15 , pp. 618
    • Farb, A.1    Devereux, R.B.2    Kligfield, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.