메뉴 건너뛰기




Volumn 117, Issue 7, 1999, Pages 868-870

Corneal thickness measurements with the Topcon SP-2000P specular microscope and an ultrasound pachymeter

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CELL DENSITY; CORNEA THICKNESS; DEVICE; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; HUMAN; HUMAN CELL; HUMAN TISSUE; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; OBSERVER VARIATION; PACHOMETRY; PRIORITY JOURNAL; REPRODUCIBILITY;

EID: 0032798810     PISSN: 00039950     EISSN: None     Source Type: Journal    
DOI: 10.1001/archopht.117.7.868     Document Type: Article
Times cited : (116)

References (10)
  • 2
    • 0030732713 scopus 로고    scopus 로고
    • Corneal thickness measurements with the Orbscan Topography System and ultrasonic pachymetry
    • Yaylali V, Kaufman SC, Thompson HW. Corneal thickness measurements with the Orbscan Topography System and ultrasonic pachymetry. J Cataract Retract Surg. 1997;23:1345-1350.
    • (1997) J Cataract Retract Surg. , vol.23 , pp. 1345-1350
    • Yaylali, V.1    Kaufman, S.C.2    Thompson, H.W.3
  • 3
    • 0024457845 scopus 로고
    • Feasibility test of a new method to measure retinal thickness noninvasively
    • Zeimer RC, Mori MT, Khoobehi B. Feasibility test of a new method to measure retinal thickness noninvasively. Invest Ophthalmol Vis Sci. 1989;30:2099-2105.
    • (1989) Invest Ophthalmol Vis Sci. , vol.30 , pp. 2099-2105
    • Zeimer, R.C.1    Mori, M.T.2    Khoobehi, B.3
  • 5
    • 0027985314 scopus 로고
    • Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography
    • Izatt JA, Hee MR, Swanson EA, et al. Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography. Arch Ophthalmol. 1994; 112:1584-1589.
    • (1994) Arch Ophthalmol. , vol.112 , pp. 1584-1589
    • Izatt, J.A.1    Hee, M.R.2    Swanson, E.A.3
  • 6
    • 0029068398 scopus 로고
    • Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography
    • Schuman JS, Hee MR, Puliafito CA, et al. Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography. Arch Ophthalmol. 1995;113:586-596.
    • (1995) Arch Ophthalmol. , vol.113 , pp. 586-596
    • Schuman, J.S.1    Hee, M.R.2    Puliafito, C.A.3
  • 7
    • 0000485558 scopus 로고
    • Analysis of messy data
    • New York, NY: Van Nostrand Reinhold
    • Milliken GA, Johnson DE. Analysis of messy data. In: Designed Experiments. New York, NY: Van Nostrand Reinhold; 1984:473.
    • (1984) Designed Experiments , pp. 473
    • Milliken, G.A.1    Johnson, D.E.2
  • 10
    • 0021675214 scopus 로고
    • A guide to pachymeters
    • Thornton SP. A guide to pachymeters. Ophthalmic Surg. 1984;15:993-995.
    • (1984) Ophthalmic Surg. , vol.15 , pp. 993-995
    • Thornton, S.P.1