Volumn 122, Issue 1, 2007, Pages 195-203

Characterization of a planar l-glutamate amperometric biosensor immobilized with a photo-crosslinkable polymer membrane

Author keywords

Biosensor; l Glutamate; Planar electrode; PVA SbQ; Shelf life

Indexed keywords

AMPEROMETRIC SENSORS; CROSSLINKING; POLYMERIC MEMBRANES; POLYVINYL ALCOHOLS; PROTEINS;

EID: 33847038747     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2006.05.022     Document Type: Article
Times cited : (12)

References (36)
  • 2
    • 0035107908 scopus 로고    scopus 로고
    • Electrochemical biosensors: recommended definitions and classification
    • Thévenot D.R., Toth K., Durst R.A., and Wilson G.S. Electrochemical biosensors: recommended definitions and classification. Biosens. Bioelectron. 9 (2001) 121-131
    • (2001) Biosens. Bioelectron. , vol.9 , pp. 121-131
    • Thévenot, D.R.1    Toth, K.2    Durst, R.A.3    Wilson, G.S.4
  • 3
    • 4544380367 scopus 로고    scopus 로고
    • Amperometric screening of bacterial food contamination using a composite modified electrode
    • Palenzuela B., Simonet B.M., Garćýa R.M., Ŕýos A., and Valcárcel M. Amperometric screening of bacterial food contamination using a composite modified electrode. Anal. Chim. Acta 524 (2004) 167-174
    • (2004) Anal. Chim. Acta , vol.524 , pp. 167-174
    • Palenzuela, B.1    Simonet, B.M.2    Garćýa, R.M.3    Ŕýos, A.4    Valcárcel, M.5
  • 5
    • 0038241338 scopus 로고    scopus 로고
    • Screen-printed amperometric immunosensor for repeated use in the flow-through mode
    • Zeravik J., and Skladal P. Screen-printed amperometric immunosensor for repeated use in the flow-through mode. Electroanalysis 11 (1999) 851-856
    • (1999) Electroanalysis , vol.11 , pp. 851-856
    • Zeravik, J.1    Skladal, P.2
  • 6
    • 0035816469 scopus 로고    scopus 로고
    • Disposable amperometric glucose sensor electrode with enzyme-immobilized nitrocellulose strip
    • Cui G., Yoo J.H., Woo B.W., Kim S.S., Cha G.S., and Nam H. Disposable amperometric glucose sensor electrode with enzyme-immobilized nitrocellulose strip. Talanta 54 (2001) 1105-1111
    • (2001) Talanta , vol.54 , pp. 1105-1111
    • Cui, G.1    Yoo, J.H.2    Woo, B.W.3    Kim, S.S.4    Cha, G.S.5    Nam, H.6
  • 7
    • 0034950479 scopus 로고    scopus 로고
    • Physical characterizations of a screen-printed electrode for use in an amperometric biosensor system
    • Grennan K., Killard A.J., and Smyth M.R. Physical characterizations of a screen-printed electrode for use in an amperometric biosensor system. Electroanalysis 13 (2001) 745-750
    • (2001) Electroanalysis , vol.13 , pp. 745-750
    • Grennan, K.1    Killard, A.J.2    Smyth, M.R.3
  • 8
    • 0034275903 scopus 로고    scopus 로고
    • Configurations used in the design of screen-printed enzymatic biosensors. A review
    • Albareda-Sirvent M., Merkoci A., and Alegret S. Configurations used in the design of screen-printed enzymatic biosensors. A review. Sens. Actuators B 69 (2000) 153-163
    • (2000) Sens. Actuators B , vol.69 , pp. 153-163
    • Albareda-Sirvent, M.1    Merkoci, A.2    Alegret, S.3
  • 9
    • 33847053080 scopus 로고    scopus 로고
    • H. Ludi, Planar electrochemical biosensors for critical-care applications. IVD Technology, 1999, http://www.devicelink.com/ivdt/archive/99/09/009.html.
  • 11
    • 0345583779 scopus 로고    scopus 로고
    • Biosensors for clinical diagnostics industry
    • Malhotra B.D., and Chaubey A. Biosensors for clinical diagnostics industry. Sens. Actuators B 91 (2003) 117-127
    • (2003) Sens. Actuators B , vol.91 , pp. 117-127
    • Malhotra, B.D.1    Chaubey, A.2
  • 13
    • 0006916703 scopus 로고
    • Immobilization of enzymes with use of photosensitive polymers having the stabazolium group
    • Ichimura K., and Watanabe S. Immobilization of enzymes with use of photosensitive polymers having the stabazolium group. J. Polym. Sci., Polym. Chem. Ed. 18 (1980) 891-902
    • (1980) J. Polym. Sci., Polym. Chem. Ed. , vol.18 , pp. 891-902
    • Ichimura, K.1    Watanabe, S.2
  • 14
    • 0021529356 scopus 로고
    • A convenient photochemical method to immobilize enzyme
    • Ichimura K. A convenient photochemical method to immobilize enzyme. J. Polym. Sci., Polym. Chem. Ed. 22 (1984) 2817-2828
    • (1984) J. Polym. Sci., Polym. Chem. Ed. , vol.22 , pp. 2817-2828
    • Ichimura, K.1
  • 15
    • 0000310864 scopus 로고
    • Catalytic materials, membranes and fabrication technologies suitable for the construction of amperometric biosensors
    • Newman J.D., White S.F., Tothill I.E., and Turner A.P.F. Catalytic materials, membranes and fabrication technologies suitable for the construction of amperometric biosensors. Anal. Chem. 67 (1995) 4594-4599
    • (1995) Anal. Chem. , vol.67 , pp. 4594-4599
    • Newman, J.D.1    White, S.F.2    Tothill, I.E.3    Turner, A.P.F.4
  • 16
    • 0000324541 scopus 로고
    • Entraped enzymed in photocrosslinkable gel for enzyme electrode
    • Marty J.L., Mionetto N., and Rouillon R. Entraped enzymed in photocrosslinkable gel for enzyme electrode. Anal. Lett. 25 (1992) 1389-1398
    • (1992) Anal. Lett. , vol.25 , pp. 1389-1398
    • Marty, J.L.1    Mionetto, N.2    Rouillon, R.3
  • 17
    • 0031164717 scopus 로고    scopus 로고
    • ISFET glucose and sucrose sensors by using platinum electrode and photo-crosslinkable polymers
    • Sohn B.K., Cho B.W., Kim C.S., and Kwon D.H. ISFET glucose and sucrose sensors by using platinum electrode and photo-crosslinkable polymers. Sens. Actuators B 41 (1997) 7-11
    • (1997) Sens. Actuators B , vol.41 , pp. 7-11
    • Sohn, B.K.1    Cho, B.W.2    Kim, C.S.3    Kwon, D.H.4
  • 19
    • 0034325074 scopus 로고    scopus 로고
    • Miniaturized real-time monitoring system for l-lactate and glucose using microfabricated multi-enzyme sensors
    • Perdomo I., Hinker H., Sundermeier H., Seifert W., Martinez O., and Knoll M. Miniaturized real-time monitoring system for l-lactate and glucose using microfabricated multi-enzyme sensors. Biosens. Bioelectron. 14 (2000) 515-522
    • (2000) Biosens. Bioelectron. , vol.14 , pp. 515-522
    • Perdomo, I.1    Hinker, H.2    Sundermeier, H.3    Seifert, W.4    Martinez, O.5    Knoll, M.6
  • 20
    • 33847083161 scopus 로고    scopus 로고
    • Immobilization of acetylcholinesterase on screen-printed electrodes: comparative study between three immobilization methods and applications to the detection of organophosphorus insecticides
    • Andreescu S., Bar L., and Marty J.L. Immobilization of acetylcholinesterase on screen-printed electrodes: comparative study between three immobilization methods and applications to the detection of organophosphorus insecticides. Sens. Actuators B 64 (2002) 171-180
    • (2002) Sens. Actuators B , vol.64 , pp. 171-180
    • Andreescu, S.1    Bar, L.2    Marty, J.L.3
  • 21
    • 0032129145 scopus 로고    scopus 로고
    • Amperometric glucose biosens or based on sol-gel organic-inorganic hybrid material
    • Wang B., Li B., Deng Q., and Dong S. Amperometric glucose biosens or based on sol-gel organic-inorganic hybrid material. Anal. Chem. 70 (1998) 3170-3174
    • (1998) Anal. Chem. , vol.70 , pp. 3170-3174
    • Wang, B.1    Li, B.2    Deng, Q.3    Dong, S.4
  • 23
    • 3142674988 scopus 로고    scopus 로고
    • Specific detection of l-glutamate in food using flow-injection analysis and enzymatic recycling of substrate
    • Khampha W., Yakovleva J., Isarangkul D., Wiyakrutta S., Meevootisom V., and Emnéus J. Specific detection of l-glutamate in food using flow-injection analysis and enzymatic recycling of substrate. Anal. Chim. Acta 518 (2004) 127-135
    • (2004) Anal. Chim. Acta , vol.518 , pp. 127-135
    • Khampha, W.1    Yakovleva, J.2    Isarangkul, D.3    Wiyakrutta, S.4    Meevootisom, V.5    Emnéus, J.6
  • 24
    • 22044446984 scopus 로고    scopus 로고
    • Sequential fluorometric quantification of γ-aminobutyrate and l-glutamate using a single line flow-injection system with immobilized-enzyme reactors
    • Tsukatani T., and Matsumoto K. Sequential fluorometric quantification of γ-aminobutyrate and l-glutamate using a single line flow-injection system with immobilized-enzyme reactors. Anal. Chim. Acta 546 (2005) 154-160
    • (2005) Anal. Chim. Acta , vol.546 , pp. 154-160
    • Tsukatani, T.1    Matsumoto, K.2
  • 25
    • 4143113463 scopus 로고    scopus 로고
    • Spectrophotometric enzymatic cycling method using l-glutamate dehydrogenase and d-phenylglycine aminotransferase for determination of l-glutamate in foods
    • Khampha W., Meevootisom V., and Wiyakrutta S. Spectrophotometric enzymatic cycling method using l-glutamate dehydrogenase and d-phenylglycine aminotransferase for determination of l-glutamate in foods. Anal. Chim. Acta 520 (2004) 133-139
    • (2004) Anal. Chim. Acta , vol.520 , pp. 133-139
    • Khampha, W.1    Meevootisom, V.2    Wiyakrutta, S.3
  • 26
    • 0028977920 scopus 로고
    • l-Glutamate biosensor using a novel l-glutamate oxidase and its amplification to flow injection analysis system
    • Ye B.C., Li Q.S., Li Y.R., Li X.B., and Yu J.T. l-Glutamate biosensor using a novel l-glutamate oxidase and its amplification to flow injection analysis system. J. Biotechnol. 42 (1995) 45-52
    • (1995) J. Biotechnol. , vol.42 , pp. 45-52
    • Ye, B.C.1    Li, Q.S.2    Li, Y.R.3    Li, X.B.4    Yu, J.T.5
  • 27
    • 14644416517 scopus 로고    scopus 로고
    • Glutamate detection from nerve cells using a planar electrodes array integrated in a microtiter plate
    • Castillo J., Blöchl A., Dennison S., Schuhmann W., and Csöregi E. Glutamate detection from nerve cells using a planar electrodes array integrated in a microtiter plate. Biosens. Bioelectron. 20 (2005) 2116-2119
    • (2005) Biosens. Bioelectron. , vol.20 , pp. 2116-2119
    • Castillo, J.1    Blöchl, A.2    Dennison, S.3    Schuhmann, W.4    Csöregi, E.5
  • 28
    • 0026522062 scopus 로고
    • Determination of l-glutamate by ampero, etric flow-injection analysis using immobilized glutamate oxidase: manifold for simultaneous detection of component signal and blank signal
    • Matsumoto K., Sakoda K., and Osajima Y. Determination of l-glutamate by ampero, etric flow-injection analysis using immobilized glutamate oxidase: manifold for simultaneous detection of component signal and blank signal. Anal. Chim. Acta 261 (1992) 155-159
    • (1992) Anal. Chim. Acta , vol.261 , pp. 155-159
    • Matsumoto, K.1    Sakoda, K.2    Osajima, Y.3
  • 29
    • 33847050729 scopus 로고    scopus 로고
    • W.T. Wu, Gene cloning characterization secretion mechanism and enzyme kinetics of l-glutamate oxidase, Doctoral Thesis, Graduate Institute of Agriculture Chemistry, National Taiwan University, 1999, p. 45.
  • 31
    • 0028005116 scopus 로고
    • Stabilization of chloroplasts by entrapment in polyvinylalcohol bearing styrylpyridinium groups
    • Rouillon R., Tocabens M., and Marty J.L. Stabilization of chloroplasts by entrapment in polyvinylalcohol bearing styrylpyridinium groups. Anal. Lett. 27 (1994) 2239-2248
    • (1994) Anal. Lett. , vol.27 , pp. 2239-2248
    • Rouillon, R.1    Tocabens, M.2    Marty, J.L.3
  • 32
    • 0034864066 scopus 로고    scopus 로고
    • Effect of pre-treatment on the surface and electrochemical properties of screen-printed carbon paste electrodes
    • Cui G., Yoo J.H., Lee J.S., Yoo J., Uhm J.H., Cha G.S., and Nam H. Effect of pre-treatment on the surface and electrochemical properties of screen-printed carbon paste electrodes. Analyst 126 (2001) 1399-1403
    • (2001) Analyst , vol.126 , pp. 1399-1403
    • Cui, G.1    Yoo, J.H.2    Lee, J.S.3    Yoo, J.4    Uhm, J.H.5    Cha, G.S.6    Nam, H.7
  • 33
    • 0029382848 scopus 로고
    • Electrocatalytic surface for the oxidation of NADH and other anionic molecules of biological significance
    • Nowall W.B., and Kuhr W.G. Electrocatalytic surface for the oxidation of NADH and other anionic molecules of biological significance. Anal. Chem. 67 (1995) 3583-3588
    • (1995) Anal. Chem. , vol.67 , pp. 3583-3588
    • Nowall, W.B.1    Kuhr, W.G.2
  • 34
    • 0032811469 scopus 로고    scopus 로고
    • Disposable creatinine sensor based on thick-film hydrogen peroxide electrode system
    • Kim E.J., Haruyama T., Yanagida Y., Kobatake E., and Aizawa M. Disposable creatinine sensor based on thick-film hydrogen peroxide electrode system. Anal. Chim. Acta 394 (1999) 225-231
    • (1999) Anal. Chim. Acta , vol.394 , pp. 225-231
    • Kim, E.J.1    Haruyama, T.2    Yanagida, Y.3    Kobatake, E.4    Aizawa, M.5
  • 35
    • 33847060725 scopus 로고    scopus 로고
    • C.Y. Chen, Studies on the purification and application of biosensor using oxidase as biomaterials. Doctoral Thesis, Graduate Institute of Agriculture Chemistry, National Taiwan University, 1987, p. 226.
  • 36
    • 0343081373 scopus 로고    scopus 로고
    • Sensitive detection of pesticide using ENFET with enzymes immobilized by cross-linking and entrapment method
    • Wan K., Chovelon J.M., Jaffrezic-Renault N., and Soldatkin A.P. Sensitive detection of pesticide using ENFET with enzymes immobilized by cross-linking and entrapment method. Sens. Actuators B 58 (1999) 399-408
    • (1999) Sens. Actuators B , vol.58 , pp. 399-408
    • Wan, K.1    Chovelon, J.M.2    Jaffrezic-Renault, N.3    Soldatkin, A.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.