메뉴 건너뛰기




Volumn 82, Issue 2, 2007, Pages 201-207

3D dose reconstruction for clinical evaluation of IMRT pretreatment verification with an EPID

Author keywords

EPID; Intensity modulated radiotherapy; Portal dosimetry; Quality assurance

Indexed keywords

ACCURACY; ALGORITHM; ARTICLE; CALIBRATION; CAMERA; CANCER RADIOTHERAPY; CLINICAL ARTICLE; COLLIMATOR; DOSIMETRY; FLUOROSCOPY; HEAD AND NECK CANCER; HUMAN; INTENSITY MODULATED RADIATION THERAPY; MEASUREMENT; PREDICTION; PRIORITY JOURNAL; QUALITY CONTROL; RADIATION DOSE; RECTUM CANCER; THREE DIMENSIONAL IMAGING; TREATMENT PLANNING;

EID: 33847018108     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radonc.2006.12.010     Document Type: Article
Times cited : (47)

References (11)
  • 1
    • 4644297164 scopus 로고    scopus 로고
    • Characteristics relevant to portal dosimetry of a cooled CCD camera-based EPID
    • Franken E.M., De Boer J.C.J., Barnhoorn J.C., et al. Characteristics relevant to portal dosimetry of a cooled CCD camera-based EPID. Med Phys 31 (2004) 2549-2551
    • (2004) Med Phys , vol.31 , pp. 2549-2551
    • Franken, E.M.1    De Boer, J.C.J.2    Barnhoorn, J.C.3
  • 2
    • 33645533283 scopus 로고    scopus 로고
    • A novel approach to accurate portal dosimetry using CCD-camera based EPIDs
    • Franken E.M., De Boer J.C.J., and Heijmen B.J.M. A novel approach to accurate portal dosimetry using CCD-camera based EPIDs. Med Phys 33 (2006) 888-903
    • (2006) Med Phys , vol.33 , pp. 888-903
    • Franken, E.M.1    De Boer, J.C.J.2    Heijmen, B.J.M.3
  • 3
    • 33847048155 scopus 로고    scopus 로고
    • A closed system for dosimetric IMRT verification with an EPID, eliminating ion chamber calibration measurements
    • Franken E., De Boer H., and Heijmen B. A closed system for dosimetric IMRT verification with an EPID, eliminating ion chamber calibration measurements. Rad Oncol 81 Supplement (2006) S157
    • (2006) Rad Oncol , vol.81 , Issue.SUPPL
    • Franken, E.1    De Boer, H.2    Heijmen, B.3
  • 4
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • Low D.A., Harms W.B., Mutic S., et al. A technique for the quantitative evaluation of dose distributions. Med Phys 25 (1998) 656-661
    • (1998) Med Phys , vol.25 , pp. 656-661
    • Low, D.A.1    Harms, W.B.2    Mutic, S.3
  • 5
    • 0029790894 scopus 로고    scopus 로고
    • Modeling dose distributions from portal dose images using the convolution/superpositions method
    • McNutt T.R., Rock Mackie T., Reckwerdt P., et al. Modeling dose distributions from portal dose images using the convolution/superpositions method. Med Phys 23 (1996) 1381-1392
    • (1996) Med Phys , vol.23 , pp. 1381-1392
    • McNutt, T.R.1    Rock Mackie, T.2    Reckwerdt, P.3
  • 6
    • 0031037018 scopus 로고    scopus 로고
    • Reporting, and analyzing dose distributions: A concept of equivalent uniform dose
    • Niemierko A. Reporting, and analyzing dose distributions: A concept of equivalent uniform dose. Med Phys 24 (1997) 103-110
    • (1997) Med Phys , vol.24 , pp. 103-110
    • Niemierko, A.1
  • 7
    • 0032717807 scopus 로고    scopus 로고
    • Dosimetric verification of intensity modulated beams produced with dynamic multileaf collimation using an electronic portal imaging device
    • Pasma K.L., Dirkx M.L.P., Kroonwijk M., et al. Dosimetric verification of intensity modulated beams produced with dynamic multileaf collimation using an electronic portal imaging device. Med Phys 26 (1999) 2373-2378
    • (1999) Med Phys , vol.26 , pp. 2373-2378
    • Pasma, K.L.1    Dirkx, M.L.P.2    Kroonwijk, M.3
  • 8
    • 0345256650 scopus 로고    scopus 로고
    • A dose delivery verification method for conventional and intensity-modulated radiation therapy using measured field fluence distributions
    • Renner W.D., Sarfaraz M., Earl M.A., et al. A dose delivery verification method for conventional and intensity-modulated radiation therapy using measured field fluence distributions. Med Phys 30 (2003) 2996-3005
    • (2003) Med Phys , vol.30 , pp. 2996-3005
    • Renner, W.D.1    Sarfaraz, M.2    Earl, M.A.3
  • 9
    • 14644390214 scopus 로고    scopus 로고
    • Three-dimensional IMRT verification with a flat-panel EPID
    • Steciw S., Warkentin B., Rathee S., et al. Three-dimensional IMRT verification with a flat-panel EPID. Med Phys 32 (2005) 600-612
    • (2005) Med Phys , vol.32 , pp. 600-612
    • Steciw, S.1    Warkentin, B.2    Rathee, S.3
  • 10
    • 4744359705 scopus 로고    scopus 로고
    • SIFT: A method to verify the IMRT fluence delivered during patient treatment using an electronic portal imaging device
    • Viera S.C., Dirkx M.L.P., Heijmen B.J.M., et al. SIFT: A method to verify the IMRT fluence delivered during patient treatment using an electronic portal imaging device. Int J Radiat Oncol Biol Phys 60 (2004) 981-993
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 981-993
    • Viera, S.C.1    Dirkx, M.L.P.2    Heijmen, B.J.M.3
  • 11
    • 33750729320 scopus 로고    scopus 로고
    • Dosimetric pretreatment verification of IMRT using an EPID; clinical experience
    • van Zijtveld M., Dirkx M.L.P., De Boer J.C.J., et al. Dosimetric pretreatment verification of IMRT using an EPID; clinical experience. Radiother Oncol 81 (2006) 168-175
    • (2006) Radiother Oncol , vol.81 , pp. 168-175
    • van Zijtveld, M.1    Dirkx, M.L.P.2    De Boer, J.C.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.