메뉴 건너뛰기




Volumn 7 VOLS, Issue , 2005, Pages 3035-3038

Intensity non-uniformity correction of magnetic resonance images using a fuzzy segmentation algorithm

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; FUZZY SETS; IMAGE SEGMENTATION; PROBLEM SOLVING;

EID: 33846931397     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/iembs.2005.1617114     Document Type: Conference Paper
Times cited : (8)

References (14)
  • 1
    • 0027850154 scopus 로고
    • Correction of intensity variations in MR Images for computer-aided tissue classification
    • B. W. Dawant, A. P. Zijdenbos, and R. A. Margolin, "Correction of intensity variations in MR Images for computer-aided tissue classification, " IEEE Trans. Medical Imaging, vol. 12, no. 4, pp. 770-781, 1993.
    • (1993) IEEE Trans. Medical Imaging , vol.12 , Issue.4 , pp. 770-781
    • Dawant, B.W.1    Zijdenbos, A.P.2    Margolin, R.A.3
  • 2
    • 0036489378 scopus 로고    scopus 로고
    • A modified fuzzy c-means algorithm for bias field estimation and segmentation of MRI data
    • M. N. Ahmed, S. M. Yamany, A. A. Farag and T. Moriarty, "A modified fuzzy c-means algorithm for bias field estimation and segmentation of MRI data," IEEE Trans. Medical Imaging, vol. 21, no. 3, pp. 193-199, 2002.
    • (2002) IEEE Trans. Medical Imaging , vol.21 , Issue.3 , pp. 193-199
    • Ahmed, M.N.1    Yamany, S.M.2    Farag, A.A.3    Moriarty, T.4
  • 3
    • 0027607954 scopus 로고
    • Polynomial modeling and reduction of RF body coil spatial inhomogeneity in MRI
    • M. Tincher, C. R.Meyer, R. Gupta and D. M. Williams, "Polynomial modeling and reduction of RF body coil spatial inhomogeneity in MRI," IEEE Trans. Medical Imaging, vol. 12, no. 2, pp. 361-365, 1993.
    • (1993) IEEE Trans. Medical Imaging , vol.12 , Issue.2 , pp. 361-365
    • Tincher, M.1    Meyer, C.R.2    Gupta, R.3    Williams, D.M.4
  • 5
    • 0034745001 scopus 로고    scopus 로고
    • Segmentation of brain MR images through a hidden markov random field model and the expectation-maximization algorithm
    • Y. Y. Zhang, M. Brady and S. Smith, "Segmentation of brain MR images through a hidden markov random field model and the expectation-maximization algorithm," IEEE Trans. Medical Imaging, vol. 20, no.1, pp. 45-57, 2001.
    • (2001) IEEE Trans. Medical Imaging , vol.20 , Issue.1 , pp. 45-57
    • Zhang, Y.Y.1    Brady, M.2    Smith, S.3
  • 8
    • 25844489923 scopus 로고    scopus 로고
    • MRI fuzzy segmentation of brain tissue using neighborhood attraction with neural network optimization
    • Accepted
    • S. Shen, W. A. Sandham, M. H. Grant, A. Sterr, "MRI fuzzy segmentation of brain tissue using neighborhood attraction with neural network optimization," IEEE Trans. Inf. Technol. Biomed., Accepted.
    • IEEE Trans. Inf. Technol. Biomed
    • Shen, S.1    Sandham, W.A.2    Grant, M.H.3    Sterr, A.4
  • 9
    • 0031987382 scopus 로고    scopus 로고
    • A nonparametric method for automatic correction of intensity nonuniformity in MRI data
    • J. G. Sled, B. Zijdenbos and A. C. Evans, "A nonparametric method for automatic correction of intensity nonuniformity in MRI data," IEEE Trans. Medical Imaging, vol. 17, pp. 89-97, 1998.
    • (1998) IEEE Trans. Medical Imaging , vol.17 , pp. 89-97
    • Sled, J.G.1    Zijdenbos, B.2    Evans, A.C.3
  • 10
  • 11
    • 21544432712 scopus 로고    scopus 로고
    • BrainWeb: Online Interface to a 3D MRI Simulated Brain Database
    • C. A. Cocosco, V. Kollokian, R. K. -S. Kwan and A.C. Evans, "BrainWeb: Online Interface to a 3D MRI Simulated Brain Database," NeuroImage, vol. 5, no. 4, part 2/4, S425, 1997.
    • (1997) NeuroImage , vol.5 , Issue.4 PART 2 4
    • Cocosco, C.A.1    Kollokian, V.2    Kwan, R.K.-S.3    Evans, A.C.4
  • 12
    • 84889173716 scopus 로고    scopus 로고
    • R. K. S. Kwan, A. C. Evans and G. B. Pike, An Extensible MRI Simulator for Post-Processing Evaluation, Visualization in Biomedical Computing (VBC'96). Lect. Notes. Comput SC, 1131, pp. 135-140, Springer-Verlag, 1996.
    • R. K. S. Kwan, A. C. Evans and G. B. Pike, "An Extensible MRI Simulator for Post-Processing Evaluation," Visualization in Biomedical Computing (VBC'96). Lect. Notes. Comput SC, vol. 1131, pp. 135-140, Springer-Verlag, 1996.
  • 13
    • 0033233097 scopus 로고    scopus 로고
    • MRI simulation-based evaluation of image-processing and classification methods
    • R. K. S. Kwan, A. C. Evans and G. B. Pike, "MRI simulation-based evaluation of image-processing and classification methods," IEEE Trans. Med. Imag., vol. 18, no. 11, pp. 1085-1097, 1999.
    • (1999) IEEE Trans. Med. Imag , vol.18 , Issue.11 , pp. 1085-1097
    • Kwan, R.K.S.1    Evans, A.C.2    Pike, G.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.