-
1
-
-
0022339872
-
Course of angina 1 to 12 years after aortocoronary bypass surgery related to changes in grafts and native coronary arteries
-
Campeau L., Enjalbert M., Lesperance J., and Bourassa M.G. Course of angina 1 to 12 years after aortocoronary bypass surgery related to changes in grafts and native coronary arteries. Can J Surg 28 (1985) 496-498
-
(1985)
Can J Surg
, vol.28
, pp. 496-498
-
-
Campeau, L.1
Enjalbert, M.2
Lesperance, J.3
Bourassa, M.G.4
-
2
-
-
9644291513
-
Long-term patency of saphenous vein and left internal mammary artery grafts after coronary artery bypass surgery: results from a Department of Veterans Affairs Cooperative Study
-
Goldman S., Zadina K., Moritz T., et al. Long-term patency of saphenous vein and left internal mammary artery grafts after coronary artery bypass surgery: results from a Department of Veterans Affairs Cooperative Study. J Am Coll Cardiol 44 (2004) 2149-2156
-
(2004)
J Am Coll Cardiol
, vol.44
, pp. 2149-2156
-
-
Goldman, S.1
Zadina, K.2
Moritz, T.3
-
3
-
-
0032167742
-
Arterial graft patency in coronary artery bypass grafting: what do we really know?
-
Mack M.J., Osborne J.A., and Shennib H. Arterial graft patency in coronary artery bypass grafting: what do we really know?. Ann Thorac Surg 66 (1998) 1055-1059
-
(1998)
Ann Thorac Surg
, vol.66
, pp. 1055-1059
-
-
Mack, M.J.1
Osborne, J.A.2
Shennib, H.3
-
4
-
-
0030245599
-
Coronary bypass graft fate and patient outcome: angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years
-
Fitzgibbon G.M., Kafka H.P., Leach A.J., et al. Coronary bypass graft fate and patient outcome: angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years. J Am Coll Cardiol 28 (1996) 616-626
-
(1996)
J Am Coll Cardiol
, vol.28
, pp. 616-626
-
-
Fitzgibbon, G.M.1
Kafka, H.P.2
Leach, A.J.3
-
5
-
-
0025322475
-
Intimal protection of bypass-veins during intraoperative storage in blood or Euro-Collins-solution: the role of medium, temperature, and time
-
Wagner R. Intimal protection of bypass-veins during intraoperative storage in blood or Euro-Collins-solution: the role of medium, temperature, and time. Thorac Cardiovasc Surg 38 (1990) 151-156
-
(1990)
Thorac Cardiovasc Surg
, vol.38
, pp. 151-156
-
-
Wagner, R.1
-
6
-
-
0037383581
-
Multi-photon microscopic evaluation of saphenous vein endothelium and its preservation with a new solution, GALA
-
Thatte H.S., Biswas K.S., Najjar S.F., et al. Multi-photon microscopic evaluation of saphenous vein endothelium and its preservation with a new solution, GALA. Ann Thorac Surg 75 (2003) 1145-1152
-
(2003)
Ann Thorac Surg
, vol.75
, pp. 1145-1152
-
-
Thatte, H.S.1
Biswas, K.S.2
Najjar, S.F.3
-
7
-
-
0035098651
-
High early patency of saphenous vein graft for coronary artery bypass harvested with surrounding tissue
-
Souza D.S., Bomfim V., Skoglund H., et al. High early patency of saphenous vein graft for coronary artery bypass harvested with surrounding tissue. Ann Thorac Surg 71 (2001) 797-800
-
(2001)
Ann Thorac Surg
, vol.71
, pp. 797-800
-
-
Souza, D.S.1
Bomfim, V.2
Skoglund, H.3
-
8
-
-
0035665359
-
The coronary artery bypass conduit: I. Intraoperative endothelial injury and its implication on graft patency
-
Thatte H.S., and Khuri S.F. The coronary artery bypass conduit: I. Intraoperative endothelial injury and its implication on graft patency. Ann Thorac Surg 72 suppl (2001) S2245-S2252
-
(2001)
Ann Thorac Surg
, vol.72
, Issue.SUPPL
-
-
Thatte, H.S.1
Khuri, S.F.2
-
10
-
-
0141955000
-
Optical Coherence Tomography (OCT). Potential of a new high-resolution intracoronary imaging technique
-
Gerckens U., Buellesfeld L., McNamara E., and Grube E. Optical Coherence Tomography (OCT). Potential of a new high-resolution intracoronary imaging technique. Herz 28 (2003) 496-500
-
(2003)
Herz
, vol.28
, pp. 496-500
-
-
Gerckens, U.1
Buellesfeld, L.2
McNamara, E.3
Grube, E.4
-
11
-
-
0037680185
-
In vitro comparison of glyceryl trinitrate-verapamil with other dilators of human saphenous vein
-
Jesuthasan L.S., Angus J.A., and Rosenfeldt F.L. In vitro comparison of glyceryl trinitrate-verapamil with other dilators of human saphenous vein. ANZ J Surg 73 (2003) 313-320
-
(2003)
ANZ J Surg
, vol.73
, pp. 313-320
-
-
Jesuthasan, L.S.1
Angus, J.A.2
Rosenfeldt, F.L.3
-
12
-
-
33746928791
-
Intravascular optical coherence tomography: comparison with histopathology in atherosclerotic peripheral artery specimens
-
Meissner O.A., Rieber J., Babaryka G., et al. Intravascular optical coherence tomography: comparison with histopathology in atherosclerotic peripheral artery specimens. J Vasc Interv Radiol 17 (2006) 343-349
-
(2006)
J Vasc Interv Radiol
, vol.17
, pp. 343-349
-
-
Meissner, O.A.1
Rieber, J.2
Babaryka, G.3
-
13
-
-
0028905580
-
Patterns of calcification in coronary artery disease. A statistical analysis of intravascular ultrasound and coronary angiography in 1155 lesions
-
Mintz G.S., Popma J.J., Pichard A.D., et al. Patterns of calcification in coronary artery disease. A statistical analysis of intravascular ultrasound and coronary angiography in 1155 lesions. Circulation 91 (1995) 1959-1965
-
(1995)
Circulation
, vol.91
, pp. 1959-1965
-
-
Mintz, G.S.1
Popma, J.J.2
Pichard, A.D.3
-
14
-
-
20444401202
-
Disruption of graft endothelium correlates with early failure after off-pump coronary artery bypass surgery
-
Manchio J.V., Gu J., Romar L., et al. Disruption of graft endothelium correlates with early failure after off-pump coronary artery bypass surgery. Ann Thorac Surg 79 (2005) 1991-1998
-
(2005)
Ann Thorac Surg
, vol.79
, pp. 1991-1998
-
-
Manchio, J.V.1
Gu, J.2
Romar, L.3
-
15
-
-
12144266269
-
A comparison of six statins on the development of intimal hyperplasia in a human vein culture model
-
Corpataux J.M., Naik J., Porter K.E., and London N.J. A comparison of six statins on the development of intimal hyperplasia in a human vein culture model. Eur J Vasc Endovasc Surg 29 (2005) 177-181
-
(2005)
Eur J Vasc Endovasc Surg
, vol.29
, pp. 177-181
-
-
Corpataux, J.M.1
Naik, J.2
Porter, K.E.3
London, N.J.4
-
16
-
-
0030822871
-
Vein quality influences neointimal hyperplasia in an organ culture model of human saphenous vein
-
Wilson Y.G., Davies A.H., Southgate K., et al. Vein quality influences neointimal hyperplasia in an organ culture model of human saphenous vein. Eur J Vasc Endovasc Surg 13 (1997) 557-562
-
(1997)
Eur J Vasc Endovasc Surg
, vol.13
, pp. 557-562
-
-
Wilson, Y.G.1
Davies, A.H.2
Southgate, K.3
-
17
-
-
0032747716
-
Influence of systemic factors on pre-existing intimal hyperplasia and their effect on the outcome of infrainguinal arterial reconstruction with vein
-
Beattie D.K., Sian M., Greenhalgh R.M., and Davies A.H. Influence of systemic factors on pre-existing intimal hyperplasia and their effect on the outcome of infrainguinal arterial reconstruction with vein. Br J Surg 86 (1999) 1441-1447
-
(1999)
Br J Surg
, vol.86
, pp. 1441-1447
-
-
Beattie, D.K.1
Sian, M.2
Greenhalgh, R.M.3
Davies, A.H.4
-
18
-
-
0026509563
-
Unsuspected preexisting saphenous vein disease: an unrecognized cause of vein bypass failure
-
Panetta T.F., Marin M.L., Veith F.J., et al. Unsuspected preexisting saphenous vein disease: an unrecognized cause of vein bypass failure. J Vasc Surg 15 (1992) 102-110
-
(1992)
J Vasc Surg
, vol.15
, pp. 102-110
-
-
Panetta, T.F.1
Marin, M.L.2
Veith, F.J.3
-
19
-
-
27544505154
-
Atherosclerosis of radial arterial graft may increase the potential of vessel spasm in coronary bypass surgery
-
Zhang Y., Janssen L., and Chu F.V. Atherosclerosis of radial arterial graft may increase the potential of vessel spasm in coronary bypass surgery. J Thorac Cardiovasc Surg 130 (2005) 1477-1478
-
(2005)
J Thorac Cardiovasc Surg
, vol.130
, pp. 1477-1478
-
-
Zhang, Y.1
Janssen, L.2
Chu, F.V.3
-
20
-
-
33645734923
-
Initial experience in endoscopic radial artery harvesting
-
Sato M., Suenaga E., Senaha S., Furutachi A., and Morokumia H. Initial experience in endoscopic radial artery harvesting. Kyobu Geka 59 (2006) 123-125
-
(2006)
Kyobu Geka
, vol.59
, pp. 123-125
-
-
Sato, M.1
Suenaga, E.2
Senaha, S.3
Furutachi, A.4
Morokumia, H.5
-
21
-
-
33645905708
-
Endoscopic radial artery harvest for coronary artery bypass surgery
-
Chiu K.M., Li S.J., Chen J.S., Lin T.Y., Chan C.Y., and Chu S.H. Endoscopic radial artery harvest for coronary artery bypass surgery. J Formos Med Assoc 105 (2006) 384-389
-
(2006)
J Formos Med Assoc
, vol.105
, pp. 384-389
-
-
Chiu, K.M.1
Li, S.J.2
Chen, J.S.3
Lin, T.Y.4
Chan, C.Y.5
Chu, S.H.6
-
22
-
-
14644393623
-
Randomized trial of endoscopic versus open vein harvest for coronary artery bypass grafting: six-month patency rates
-
Yun K.L., Wu Y., Aharonian V., et al. Randomized trial of endoscopic versus open vein harvest for coronary artery bypass grafting: six-month patency rates. J Thorac Cardiovasc Surg 129 (2005) 496-503
-
(2005)
J Thorac Cardiovasc Surg
, vol.129
, pp. 496-503
-
-
Yun, K.L.1
Wu, Y.2
Aharonian, V.3
-
23
-
-
0035822324
-
Systematic reviews in health care: assessing the quality of controlled clinical trials
-
Juni P., Altman D.G., and Egger M. Systematic reviews in health care: assessing the quality of controlled clinical trials. BMJ 323 (2001) 42-46
-
(2001)
BMJ
, vol.323
, pp. 42-46
-
-
Juni, P.1
Altman, D.G.2
Egger, M.3
-
24
-
-
19644399004
-
Histopathology and morphometry of radial artery conduits: basic study and clinical application
-
Chowdhury U.K., Airan B., Mishra P.K., et al. Histopathology and morphometry of radial artery conduits: basic study and clinical application. Ann Thorac Surg 78 (2004) 1614-1621
-
(2004)
Ann Thorac Surg
, vol.78
, pp. 1614-1621
-
-
Chowdhury, U.K.1
Airan, B.2
Mishra, P.K.3
-
25
-
-
23744458331
-
Assessment of coronary intima-media thickness by optical coherence tomography: comparison with intravascular ultrasound
-
Kume T., Akasaka T., Kawamoto T., et al. Assessment of coronary intima-media thickness by optical coherence tomography: comparison with intravascular ultrasound. Circ J 69 (2005) 903-907
-
(2005)
Circ J
, vol.69
, pp. 903-907
-
-
Kume, T.1
Akasaka, T.2
Kawamoto, T.3
-
26
-
-
33645730616
-
Assessment of coronary arterial plaque by optical coherence tomography
-
Kume T., Akasaka T., Kawamoto T., et al. Assessment of coronary arterial plaque by optical coherence tomography. Am J Cardiol 97 (2006) 1172-1175
-
(2006)
Am J Cardiol
, vol.97
, pp. 1172-1175
-
-
Kume, T.1
Akasaka, T.2
Kawamoto, T.3
-
27
-
-
32544450146
-
Intravascular optical coherence tomography: differentiation of atherosclerotic plaques and quantification of vessel dimensions in crural arterial specimens
-
Meissner O.A., Rieber J., Babaryka G., et al. Intravascular optical coherence tomography: differentiation of atherosclerotic plaques and quantification of vessel dimensions in crural arterial specimens. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 178 (2006) 214-220
-
(2006)
Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr
, vol.178
, pp. 214-220
-
-
Meissner, O.A.1
Rieber, J.2
Babaryka, G.3
-
28
-
-
21344460533
-
Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound
-
Leber A.W., Knez A., von Ziegler F., et al. Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 46 (2005) 147-154
-
(2005)
J Am Coll Cardiol
, vol.46
, pp. 147-154
-
-
Leber, A.W.1
Knez, A.2
von Ziegler, F.3
|