메뉴 건너뛰기




Volumn 20, Issue 1, 2007, Pages 12-19

The Accuracy of Goniometric Measurements of Proximal Interphalangeal Joints in Fresh Cadavers: Comparison between Methods of Measurement, Types of Goniometers, and Fingers

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; AGED; ARTICLE; CADAVER; COMPARATIVE STUDY; CORRELATION COEFFICIENT; FEMALE; FINGER; GONIOMETRY; HAND RADIOGRAPHY; HUMAN; INDEX FINGER; INTERRATER RELIABILITY; MALE; MEASUREMENT; METHODOLOGY; PROXIMAL INTERPHALANGEAL JOINT; RANGE OF MOTION;

EID: 33846335518     PISSN: 08941130     EISSN: 1545004X     Source Type: Journal    
DOI: 10.1197/j.jht.2006.11.015     Document Type: Article
Times cited : (23)

References (11)
  • 1
    • 0022398737 scopus 로고
    • Sources of goniometric error at the elbow
    • Fish D.R., and Wingate L. Sources of goniometric error at the elbow. Phys Ther 65 (1985) 1666-1670
    • (1985) Phys Ther , vol.65 , pp. 1666-1670
    • Fish, D.R.1    Wingate, L.2
  • 2
    • 0035140367 scopus 로고    scopus 로고
    • Goniometry of the proximal and distal interphalangeal joints, Part II: Placement preferences, interrater reliability, and concurrent validity
    • Groth G.N., and Ehrestman R.L. Goniometry of the proximal and distal interphalangeal joints, Part II: Placement preferences, interrater reliability, and concurrent validity. J Hand Ther 14 (2001) 18-22
    • (2001) J Hand Ther , vol.14 , pp. 18-22
    • Groth, G.N.1    Ehrestman, R.L.2
  • 3
    • 0035140367 scopus 로고    scopus 로고
    • Goniometry of the proximal and distal interphalangeal joints, Part I: A survey of instrumental and placement preferences
    • Groth G.N., VanDeven K.M., Phillips E.C., and Ehrestman R.L. Goniometry of the proximal and distal interphalangeal joints, Part I: A survey of instrumental and placement preferences. J Hand Ther 14 (2001) 23-29
    • (2001) J Hand Ther , vol.14 , pp. 23-29
    • Groth, G.N.1    VanDeven, K.M.2    Phillips, E.C.3    Ehrestman, R.L.4
  • 4
    • 0014512173 scopus 로고
    • Reliability of goniometer in assessing finger joint angle
    • Hamilton G.F., and Lachenbruch P.A. Reliability of goniometer in assessing finger joint angle. Phys Ther 49 (1969) 465-469
    • (1969) Phys Ther , vol.49 , pp. 465-469
    • Hamilton, G.F.1    Lachenbruch, P.A.2
  • 5
    • 0032843325 scopus 로고    scopus 로고
    • Intratester and intertester reliability of goniometric measurement of passive lateral shoulder rotation
    • MacDermid J.C., Chesworth B.M., Patterson S., and Roth J.H. Intratester and intertester reliability of goniometric measurement of passive lateral shoulder rotation. J Hand Ther 12 (1999) 187-192
    • (1999) J Hand Ther , vol.12 , pp. 187-192
    • MacDermid, J.C.1    Chesworth, B.M.2    Patterson, S.3    Roth, J.H.4
  • 6
    • 0023227223 scopus 로고
    • Goniometric reliability in a clinical setting. Shoulder measurements
    • Riddle D.L., Rothstein J.M., and Lamb R.L. Goniometric reliability in a clinical setting. Shoulder measurements. Phys Ther 67 (1987) 668-673
    • (1987) Phys Ther , vol.67 , pp. 668-673
    • Riddle, D.L.1    Rothstein, J.M.2    Lamb, R.L.3
  • 7
    • 0025407082 scopus 로고
    • The reliability of goniometric measurements of active and passive wrist motions
    • Horger M.M. The reliability of goniometric measurements of active and passive wrist motions. Am J Occup Ther 44 (1989) 342-348
    • (1989) Am J Occup Ther , vol.44 , pp. 342-348
    • Horger, M.M.1
  • 8
    • 0027958611 scopus 로고
    • Reliability of passive wrist flexion and extension goniometric measurements: a multicenter study
    • LaStayo P.L., and Wheeler D.L. Reliability of passive wrist flexion and extension goniometric measurements: a multicenter study. Phys Ther 74 (1994) 162-173
    • (1994) Phys Ther , vol.74 , pp. 162-173
    • LaStayo, P.L.1    Wheeler, D.L.2
  • 10
    • 0020525827 scopus 로고
    • Comparison of two methods of goniometry
    • Loessin Grohmann J.E. Comparison of two methods of goniometry. Phys Ther 63 (1983) 922-925
    • (1983) Phys Ther , vol.63 , pp. 922-925
    • Loessin Grohmann, J.E.1
  • 11
    • 0020514697 scopus 로고
    • Goniometric reliability in a clinical setting. Elbow and knee measurements
    • Rothstein J.M., Miller P.J., and Roettger R.F. Goniometric reliability in a clinical setting. Elbow and knee measurements. Phys Ther 63 (1983) 1611-1615
    • (1983) Phys Ther , vol.63 , pp. 1611-1615
    • Rothstein, J.M.1    Miller, P.J.2    Roettger, R.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.