Volumn 330-332 II, Issue , 2007, Pages 999-1002
|
Comparison of porous Ti6Al4V made by sponge replication and directly 3D fiber deposition and cancellous bone
|
Author keywords
3D fiber deposition scaffold; Orthopaedic implant; Porous; Titanium
|
Indexed keywords
BONE;
COMPRESSIVE STRENGTH;
MICROSTRUCTURE;
ORTHOPEDICS;
POROUS MATERIALS;
STIFFNESS;
3D FIBER DEPOSITION SCAFFOLDS;
OPEN PORE STRUCTURES;
ORTHOPAEDIC IMPLANT;
SPONGE REPLICATION;
TITANIUM COMPOUNDS;
|
EID: 33846334029
PISSN: 10139826
EISSN: 16629795
Source Type: Book Series
DOI: 10.4028/0-87849-422-7.999 Document Type: Conference Paper |
Times cited : (9)
|
References (6)
|