메뉴 건너뛰기




Volumn 21, Issue 6, 2006, Pages 879-889

Threaded versus porous-surfaced implants as anchorage units for orthodontic treatment: Three-dimensional finite element analysis of peri-implant bone tissue stresses

Author keywords

Crestal bone loss; Finite element analysis; Implant surfaces

Indexed keywords

ANIMAL; ARTICLE; BIOLOGICAL MODEL; BONE REGENERATION; COMPUTER SIMULATION; DOG; FINITE ELEMENT ANALYSIS; HISTOLOGY; INSTRUMENTATION; JAW; MANDIBLE; MECHANICAL STRESS; ORTHODONTIC DEVICE; ORTHODONTICS; OSTEOLYSIS; PATHOPHYSIOLOGY; PHYSIOLOGY; POROSITY; PREMOLAR TOOTH; SURFACE PROPERTY; THREE DIMENSIONAL IMAGING; TIME; TOOTH IMPLANTATION; TOOTH PROSTHESIS;

EID: 33846331705     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (32)

References (31)
  • 1
    • 0031065978 scopus 로고    scopus 로고
    • Prosthodontic considerations when using implants for orthodontic anchorage
    • Goodacre O, Brown DT, Roberts WE, Jeiroudi MT. Prosthodontic considerations when using implants for orthodontic anchorage. J Prosthet Dent 1997;77:162-170.
    • (1997) J Prosthet Dent , vol.77 , pp. 162-170
    • Goodacre, O.1    Brown, D.T.2    Roberts, W.E.3    Jeiroudi, M.T.4
  • 2
    • 0033169907 scopus 로고    scopus 로고
    • Implant anchorage for the occlusal management of developmental defects in children: A preliminary report
    • Henry PJ, Singer S. Implant anchorage for the occlusal management of developmental defects in children: A preliminary report. Pract Periodontics Aesthet Dent 1999;11:699-706.
    • (1999) Pract Periodontics Aesthet Dent , vol.11 , pp. 699-706
    • Henry, P.J.1    Singer, S.2
  • 3
    • 0031266937 scopus 로고    scopus 로고
    • Mini-implant for orthodontic anchorage
    • Kanomi R. Mini-implant for orthodontic anchorage. J Clin Orthod 1997;31:763-767.
    • (1997) J Clin Orthod , vol.31 , pp. 763-767
    • Kanomi, R.1
  • 4
    • 0038622004 scopus 로고    scopus 로고
    • Distalization of maxillary molars with a midpalatal miniscrew
    • Kyung SH, Hong SG, Park YC. Distalization of maxillary molars with a midpalatal miniscrew. J Clin Orthod 2003;37:22-26.
    • (2003) J Clin Orthod , vol.37 , pp. 22-26
    • Kyung, S.H.1    Hong, S.G.2    Park, Y.C.3
  • 7
    • 0033142077 scopus 로고    scopus 로고
    • Bone response to orthodontic loading of endosseous implants in the rabbit calvaria: Early continuous distalizing forces
    • Majzoub Z, Finotti M. Miotti F, Giardino R, Aldini NN, Cordioli G. Bone response to orthodontic loading of endosseous implants in the rabbit calvaria: Early continuous distalizing forces. Eur J Orthod 1999;21:223-230.
    • (1999) Eur J Orthod , vol.21 , pp. 223-230
    • Majzoub, Z.1    Finotti, M.2    Miotti, F.3    Giardino, R.4    Aldini, N.N.5    Cordioli, G.6
  • 8
    • 0031107903 scopus 로고    scopus 로고
    • Orthodontic anchorage capacity of short titanium screw implants in the maxilla. An experimental study in the dog
    • Wehrbein H, Glatzmaier J, Yildrim M. Orthodontic anchorage capacity of short titanium screw implants in the maxilla. An experimental study in the dog. Clin Oral Implants Res 1997;8:131-141.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 131-141
    • Wehrbein, H.1    Glatzmaier, J.2    Yildrim, M.3
  • 9
    • 1342322625 scopus 로고    scopus 로고
    • A prospective study of risk factors associated with failure of mini-implants used for orthodontic anchorage
    • Cheng S-J, Tseng I-Y, Lee J-J, Kok S-H. A prospective study of risk factors associated with failure of mini-implants used for orthodontic anchorage. Int J Oral Maxillofac Implants 2004;19:100-106.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 100-106
    • Cheng, S.-J.1    Tseng, I.-Y.2    Lee, J.-J.3    Kok, S.-H.4
  • 10
    • 0032249955 scopus 로고    scopus 로고
    • Overview of surface variability of metallic endosseous dental implants: Textured and porous-surfaced designs
    • Pilliar RM. Overview of surface variability of metallic endosseous dental implants: Textured and porous-surfaced designs. Implant Dent 1998;7:305-314.
    • (1998) Implant Dent , vol.7 , pp. 305-314
    • Pilliar, R.M.1
  • 11
    • 0037505753 scopus 로고    scopus 로고
    • Ten-year results of a prospective study using porous-surfaced dental implants and a mandibularoverdenture
    • Deporter DA, Watson PA, Pharoah M, Todescan R, Tomlinson G. Ten-year results of a prospective study using porous-surfaced dental implants and a mandibularoverdenture. Clin Implants Dent Relat Res 2002;4:183-189.
    • (2002) Clin Implants Dent Relat Res , vol.4 , pp. 183-189
    • Deporter, D.A.1    Watson, P.A.2    Pharoah, M.3    Todescan, R.4    Tomlinson, G.5
  • 12
    • 0035461999 scopus 로고    scopus 로고
    • Managing the posterior mandible of partially edentulous patients with short, porous-surfaced dental implants: Early data from a clinical trial
    • Deporter DA, Pilliar RM, Todescan R, Watson PA, Pharoah M. Managing the posterior mandible of partially edentulous patients with short, porous-surfaced dental implants: Early data from a clinical trial. Int J Oral Maxillofac Implants 2001;16:653-658.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 653-658
    • Deporter, D.A.1    Pilliar, R.M.2    Todescan, R.3    Watson, P.A.4    Pharoah, M.5
  • 13
    • 3543026382 scopus 로고    scopus 로고
    • A targeted review of study outcomes with short (7 mm or less) endosseous dental implants placed in partially edentulous patients
    • Hagi D, Deporter DA, Pilliar RM, Arenovich T. A targeted review of study outcomes with short (7 mm or less) endosseous dental implants placed in partially edentulous patients. J Periodontol 2004;75:796-802.
    • (2004) J Periodontol , vol.75 , pp. 796-802
    • Hagi, D.1    Deporter, D.A.2    Pilliar, R.M.3    Arenovich, T.4
  • 14
    • 0035406264 scopus 로고    scopus 로고
    • A prospective human clinical trial of Endopore dental implants in restoring partially edentulous maxilla using fixed prostheses
    • Deporter DA, Todescan R, Watson PA, Pharoah M, Pilliar RM, Jomlinson G. A prospective human clinical trial of Endopore dental implants in restoring partially edentulous maxilla using fixed prostheses. Int J Oral Maxillofac Implants 2001;16:527-536.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 527-536
    • Deporter, D.A.1    Todescan, R.2    Watson, P.A.3    Pharoah, M.4    Pilliar, R.M.5    Jomlinson, G.6
  • 15
    • 3543002104 scopus 로고    scopus 로고
    • Processing and properties of endosseous dental implant surfaces: Design for increased osseointegration potential
    • August
    • Pilliar RM. Processing and properties of endosseous dental implant surfaces: Design for increased osseointegration potential. Oral Health 2000;(August):51-58.
    • (2000) Oral Health , pp. 51-58
    • Pilliar, R.M.1
  • 17
    • 0032840782 scopus 로고    scopus 로고
    • Osseointegration of sintered porous-surfaced and plasma-spray coated implants: An animal model study of early post-implantation healing response and mechanical stability
    • Simmons CA, Valiquette N, Pilliar RM. Osseointegration of sintered porous-surfaced and plasma-spray coated implants: An animal model study of early post-implantation healing response and mechanical stability. J Biomed Mater Res 1999;47:127-138.
    • (1999) J Biomed Mater Res , vol.47 , pp. 127-138
    • Simmons, C.A.1    Valiquette, N.2    Pilliar, R.M.3
  • 19
    • 0035136691 scopus 로고    scopus 로고
    • Mechanical regulation of localized and appositional bone formation around bone-interfacing implants
    • Simmons CA, Meguid SA, Pilliar RM. Mechanical regulation of localized and appositional bone formation around bone-interfacing implants. J Biomed Mater Res 2001;55:63-71.
    • (2001) J Biomed Mater Res , vol.55 , pp. 63-71
    • Simmons, C.A.1    Meguid, S.A.2    Pilliar, R.M.3
  • 20
    • 23344450440 scopus 로고    scopus 로고
    • Peri-implant bone response to orthodontic loading: Part 1. The effects of implant surface design, a histomorphometric study
    • Oyonarte R, Deporter D, Pilliar RM, Woodside DG. Peri-implant bone response to orthodontic loading: Part 1. The effects of implant surface design, a histomorphometric study. Am J Orthod Dentofacial Orthop 2005;128:173-181.
    • (2005) Am J Orthod Dentofacial Orthop , vol.128 , pp. 173-181
    • Oyonarte, R.1    Deporter, D.2    Pilliar, R.M.3    Woodside, D.G.4
  • 21
    • 23344433245 scopus 로고    scopus 로고
    • Peri-implant bone response to orthodontic loading: Part 2. Implant surface geometry and its impact on regional bone remodeling
    • Oyonarte R, Deporter D, Pilliar RM, Woodside DG. Peri-implant bone response to orthodontic loading: Part 2. Implant surface geometry and its impact on regional bone remodeling. Am J Orthod Dentofacia Orthop, 2005;128;182-189.
    • (2005) Am J Orthod Dentofacia Orthop , vol.128 , pp. 182-189
    • Oyonarte, R.1    Deporter, D.2    Pilliar, R.M.3    Woodside, D.G.4
  • 23
    • 33846311714 scopus 로고    scopus 로고
    • ANSYS Structural Analysis Guide, Version 5.6 and higher, ANSYS Online Help, SAS [unpublished work, 2003]. Available at: http://www.oulu.fi/atkk/ tkpalv/unix/ansys6.1/content/index.html
    • ANSYS Structural Analysis Guide, Version 5.6 and higher, ANSYS Online Help, SAS [unpublished work, 2003]. Available at: http://www.oulu.fi/atkk/ tkpalv/unix/ansys6.1/content/index.html
  • 24
    • 33846290990 scopus 로고    scopus 로고
    • ANSYS User's Manual, ver. 5.6-8.0. Cary, NC: SAS, 2000-2004.
    • ANSYS User's Manual, ver. 5.6-8.0. Cary, NC: SAS, 2000-2004.
  • 25
    • 0031554431 scopus 로고    scopus 로고
    • Friction properties at the bone-metal interface: Comparison of four different porous metal surfaces
    • Dammak M, Shirazi-Adl M, Schwartz Jr M, Gustavson L. Friction properties at the bone-metal interface: Comparison of four different porous metal surfaces. J Biomechanics 1997;35:329-336.
    • (1997) J Biomechanics , vol.35 , pp. 329-336
    • Dammak, M.1    Shirazi-Adl, M.2    Schwartz Jr, M.3    Gustavson, L.4
  • 26
    • 0029415087 scopus 로고
    • Finite element analysis of crestal bone loss around porous-coated dental implants
    • Vaillancourt H, Pilliar RM, McCammond D. Finite element analysis of crestal bone loss around porous-coated dental implants. J Appl Biomater 1995;6:267-282.
    • (1995) J Appl Biomater , vol.6 , pp. 267-282
    • Vaillancourt, H.1    Pilliar, R.M.2    McCammond, D.3
  • 27
    • 0026245670 scopus 로고
    • The effect of partial coating with hydroxyapatite on bone remodeling in relation to porous-coated titanium-alloy dental implants in the dog
    • Pilliar RM, Deporter DA, Watson PA, et al. The effect of partial coating with hydroxyapatite on bone remodeling in relation to porous-coated titanium-alloy dental implants in the dog. J Dent Res 1991;70:1338-1345.
    • (1991) J Dent Res , vol.70 , pp. 1338-1345
    • Pilliar, R.M.1    Deporter, D.A.2    Watson, P.A.3
  • 28
    • 0028509555 scopus 로고
    • Predictable crestal bone remodelling around two porous-coated titanium alloy dental implant designs. A radiographic study in dogs
    • Al-Sayyed A, Deporter DA, Pilliar RM, et al. Predictable crestal bone remodelling around two porous-coated titanium alloy dental implant designs. A radiographic study in dogs. Clin Oral Implants Res 1994;5:131-141.
    • (1994) Clin Oral Implants Res , vol.5 , pp. 131-141
    • Al-Sayyed, A.1    Deporter, D.A.2    Pilliar, R.M.3
  • 29
    • 0030224033 scopus 로고    scopus 로고
    • The periimplant hard and soft tissues at different implant systems. A comparative study in the dog
    • Abrahamsson I, Berglundh T, Wennstrom J, Lindhe J. The periimplant hard and soft tissues at different implant systems. A comparative study in the dog. Clin Oral Implants Res 1996;7:212-219.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 212-219
    • Abrahamsson, I.1    Berglundh, T.2    Wennstrom, J.3    Lindhe, J.4
  • 30
    • 0345406771 scopus 로고
    • Fundamental principles of bone physiology, metabolism and loading
    • Naert I, van Steenberghe D, Worthington P eds, London: Quintessence
    • Roberts WE. Fundamental principles of bone physiology, metabolism and loading. In: Naert I, van Steenberghe D, Worthington P (eds). Osseointegration in Oral Rehabilitation: An Introductory Textbook. London: Quintessence, 1993:157-180.
    • (1993) Osseointegration in Oral Rehabilitation: An Introductory Textbook , pp. 157-180
    • Roberts, W.E.1
  • 31
    • 33846302400 scopus 로고    scopus 로고
    • Influence of implant design and bone quality on stress/strain distribution in bone around implants: A 3-dimensional finite element analysis
    • Tada S, Stegaroiu R, Kitamura E, Miyakawa O, Kusakari H. Influence of implant design and bone quality on stress/strain distribution in bone around implants: A 3-dimensional finite element analysis. Int J Oral Maxillofac Implants 2001;16:527-536.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 527-536
    • Tada, S.1    Stegaroiu, R.2    Kitamura, E.3    Miyakawa, O.4    Kusakari, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.