메뉴 건너뛰기




Volumn 23, Issue 1, 2007, Pages 45-49

LASIK flap characteristics using the moria M2 microkeratome with the 90-μm single use head

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ADULT; ARTICLE; CORNEA; DEVICE; FEMALE; HUMAN; KERATOMETRY; KERATOMILEUSIS; MAJOR CLINICAL STUDY; MALE; MICROTOME; MYOPIA; POSTOPERATIVE PERIOD; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; PROSPECTIVE STUDY; SAFETY; TISSUE FLAP; TREATMENT OUTCOME;

EID: 33846299205     PISSN: 1081597X     EISSN: None     Source Type: Journal    
DOI: 10.3928/1081-597x-20070101-08     Document Type: Article
Times cited : (19)

References (32)
  • 1
    • 0024993348 scopus 로고    scopus 로고
    • Pallikaris IG, Papatzanaki ME, Stathi EZ, Frenschock O, Georgiadis A. Laser in situ keratomileusis. Lasers Surg Med. 1990;10:463-468.
    • Pallikaris IG, Papatzanaki ME, Stathi EZ, Frenschock O, Georgiadis A. Laser in situ keratomileusis. Lasers Surg Med. 1990;10:463-468.
  • 2
    • 0033504885 scopus 로고    scopus 로고
    • Comparison of photorefractive keratectomy with excimer laser in situ keratomileusis in correcting low myopia (from -2.00 to -5.50 D): A randomized study
    • El Danasoury MA, El Maghraby A, Klyce SD, Mehrez K. Comparison of photorefractive keratectomy with excimer laser in situ keratomileusis in correcting low myopia (from -2.00 to -5.50 D): a randomized study. Ophthalmology. 1999;106:411-420.
    • (1999) Ophthalmology , vol.106 , pp. 411-420
    • El Danasoury, M.A.1    El Maghraby, A.2    Klyce, S.D.3    Mehrez, K.4
  • 3
    • 0036141008 scopus 로고    scopus 로고
    • Incidence of intraoperative flap complications in laser in situ keratomileusis
    • Jacobs JM, Taravella MJ. Incidence of intraoperative flap complications in laser in situ keratomileusis. J Cataract Refract Surg. 2002;28:23-28.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 23-28
    • Jacobs, J.M.1    Taravella, M.J.2
  • 4
    • 0033806345 scopus 로고    scopus 로고
    • Microkeratome complications of laser in keratomileusis
    • Tham VM, Maloney RK. Microkeratome complications of laser in keratomileusis. Ophthalmology. 2000;107:920-924.
    • (2000) Ophthalmology , vol.107 , pp. 920-924
    • Tham, V.M.1    Maloney, R.K.2
  • 5
    • 0033040672 scopus 로고    scopus 로고
    • Flap complications associated with lamellar refractive surgery
    • Lin RT, Maloney RK. Flap complications associated with lamellar refractive surgery. Am J Ophthalmol. 1999;127:129-136.
    • (1999) Am J Ophthalmol , vol.127 , pp. 129-136
    • Lin, R.T.1    Maloney, R.K.2
  • 7
    • 0031790753 scopus 로고    scopus 로고
    • Incidence and management of intraoperative and early postoperative complications in 1000 consecutive laser in situ keratomileusis cases
    • Gimbel HV, Penno EE, van Westenbrugge JA, Ferensowicz M, Furlong MT. Incidence and management of intraoperative and early postoperative complications in 1000 consecutive laser in situ keratomileusis cases. Ophthalmology. 1998;105:1839-1847.
    • (1998) Ophthalmology , vol.105 , pp. 1839-1847
    • Gimbel, H.V.1    Penno, E.E.2    van Westenbrugge, J.A.3    Ferensowicz, M.4    Furlong, M.T.5
  • 9
  • 10
    • 0031943243 scopus 로고    scopus 로고
    • Results and complications of laser in situ keratomileusis by experienced surgeons
    • Davidorf JM, Zaldivar R, Oscherow S. Results and complications of laser in situ keratomileusis by experienced surgeons. J Refract Surg. 1998;14:114-122.
    • (1998) J Refract Surg , vol.14 , pp. 114-122
    • Davidorf, J.M.1    Zaldivar, R.2    Oscherow, S.3
  • 11
    • 0036153277 scopus 로고    scopus 로고
    • Risk factors for insufficient fixation of microkeratome during laser in situ keratomileusis
    • Asano-Kato N, Toda I, Hori-Komai Y, Takano Y, Tsubota K. Risk factors for insufficient fixation of microkeratome during laser in situ keratomileusis. J Refract Surg. 2002;18:47-50.
    • (2002) J Refract Surg , vol.18 , pp. 47-50
    • Asano-Kato, N.1    Toda, I.2    Hori-Komai, Y.3    Takano, Y.4    Tsubota, K.5
  • 12
    • 0030063372 scopus 로고    scopus 로고
    • Excimer laser in situ keratomileusis under a corneal flap for myopia of 2 to 20 diopters
    • Salah T, Waring GO III, El-Maghraby A, Moadel K, Grimm SB. Excimer laser in situ keratomileusis under a corneal flap for myopia of 2 to 20 diopters. Am J Ophthalmol. 1996;121:143-155.
    • (1996) Am J Ophthalmol , vol.121 , pp. 143-155
    • Salah, T.1    Waring III, G.O.2    El-Maghraby, A.3    Moadel, K.4    Grimm, S.B.5
  • 13
    • 0033956692 scopus 로고    scopus 로고
    • Lower intraoperative flap complications rate with the Hansatome microkeratome compared to the Automated Corneal Shaper
    • Walker MB, Wilson SE. Lower intraoperative flap complications rate with the Hansatome microkeratome compared to the Automated Corneal Shaper. J Refract Surg. 2000;16:79-82.
    • (2000) J Refract Surg , vol.16 , pp. 79-82
    • Walker, M.B.1    Wilson, S.E.2
  • 15
    • 25144473411 scopus 로고    scopus 로고
    • Moria M2 single use microkeratome head in 100 consecutive LASIK procedures
    • Kanellopoulos AJ, Pe LH, Kleiman L. Moria M2 single use microkeratome head in 100 consecutive LASIK procedures. J Refract Surg. 2005;21:476-479.
    • (2005) J Refract Surg , vol.21 , pp. 476-479
    • Kanellopoulos, A.J.1    Pe, L.H.2    Kleiman, L.3
  • 16
    • 0036136894 scopus 로고    scopus 로고
    • Pallikaris IG, Katsanevaki VJ, Panagopoulou SI. Laser in situ keratomileusis intraoperative complications using one type of microkeratome. Ophthalmology. 2002;109:57-63.
    • Pallikaris IG, Katsanevaki VJ, Panagopoulou SI. Laser in situ keratomileusis intraoperative complications using one type of microkeratome. Ophthalmology. 2002;109:57-63.
  • 20
    • 0141848324 scopus 로고    scopus 로고
    • Comparison of flap thickness reproducibility using microkeratomes with a second motor for advancement
    • Miranda D, Smith SD, Krueger RR. Comparison of flap thickness reproducibility using microkeratomes with a second motor for advancement. Ophthalmology. 2003;110:1931-1934.
    • (2003) Ophthalmology , vol.110 , pp. 1931-1934
    • Miranda, D.1    Smith, S.D.2    Krueger, R.R.3
  • 21
    • 0035468467 scopus 로고    scopus 로고
    • Flap analysis: Critical point in laser in situ keratomileusis
    • Srivannaboon S. Flap analysis: critical point in laser in situ keratomileusis. J Med Assoc Thai. 2001;84:1317-1320.
    • (2001) J Med Assoc Thai , vol.84 , pp. 1317-1320
    • Srivannaboon, S.1
  • 22
    • 0036579844 scopus 로고    scopus 로고
    • Predictability of corneal flap thickness in laser in situ keratomileusis using three different microkeratomes
    • Shemesh G, Dotan G, Lipshitz I. Predictability of corneal flap thickness in laser in situ keratomileusis using three different microkeratomes. J Refract Surg. 2002;18:S347-S351.
    • (2002) J Refract Surg , vol.18
    • Shemesh, G.1    Dotan, G.2    Lipshitz, I.3
  • 24
    • 13544271252 scopus 로고    scopus 로고
    • Comparison of the IntraLase femtosecond laser and mechanical keratomes for laser in situ keratomileusis
    • Kezirian GM, Stonecipher KG. Comparison of the IntraLase femtosecond laser and mechanical keratomes for laser in situ keratomileusis. J Cataract Refract Surg. 2004;30:804-811.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 804-811
    • Kezirian, G.M.1    Stonecipher, K.G.2
  • 25
    • 0037344313 scopus 로고    scopus 로고
    • Precision of flap measurements for laser in situ keratomileusis in 4428 eyes
    • Flanagan GW, Binder PS. Precision of flap measurements for laser in situ keratomileusis in 4428 eyes. J Refract Surg. 2003;19:113-123.
    • (2003) J Refract Surg , vol.19 , pp. 113-123
    • Flanagan, G.W.1    Binder, P.S.2
  • 26
    • 0035989292 scopus 로고    scopus 로고
    • Factors that affect corneal flap thickness with the Hansatome microkeratome
    • Gailitis RP, Lagzdins M. Factors that affect corneal flap thickness with the Hansatome microkeratome. J Refract Surg. 2002;18:439-443.
    • (2002) J Refract Surg , vol.18 , pp. 439-443
    • Gailitis, R.P.1    Lagzdins, M.2
  • 27
    • 0034198992 scopus 로고    scopus 로고
    • Corneal flap dimensions in laser in situ keratomileusis using the Innovatome automatic microkeratome
    • Choi YI, Park SJ, Song BJ. Corneal flap dimensions in laser in situ keratomileusis using the Innovatome automatic microkeratome. Korean J Ophthalmol. 2000;14:7-11.
    • (2000) Korean J Ophthalmol , vol.14 , pp. 7-11
    • Choi, Y.I.1    Park, S.J.2    Song, B.J.3
  • 28
    • 0034537228 scopus 로고    scopus 로고
    • Reproducibility of corneal flap thickness in laser in situ keratomileusis using the Hansatome microkeratome
    • Yildirim R, Aras C, Ozdamar A, Bahcecioglu H, Ozkan S. Reproducibility of corneal flap thickness in laser in situ keratomileusis using the Hansatome microkeratome. J Cataract Refract Surg. 2000;26:1729-1732.
    • (2000) J Cataract Refract Surg , vol.26 , pp. 1729-1732
    • Yildirim, R.1    Aras, C.2    Ozdamar, A.3    Bahcecioglu, H.4    Ozkan, S.5
  • 29
    • 0036237923 scopus 로고    scopus 로고
    • Corneal flap thickness in laser in situ keratomileusis using the Summit Krumeich-Barraquer microkeratome
    • Ucakhan OO. Corneal flap thickness in laser in situ keratomileusis using the Summit Krumeich-Barraquer microkeratome. J Cataract Refract Surg. 2002;28:798-804.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 798-804
    • Ucakhan, O.O.1
  • 30
    • 0032789771 scopus 로고    scopus 로고
    • Corneal flap thickness in laser in situ keratomileusis using an SCMD manual microkeratome
    • Yi WM, Joo CK. Corneal flap thickness in laser in situ keratomileusis using an SCMD manual microkeratome. J Cataract Refract Surg. 1999;25:1087-1092.
    • (1999) J Cataract Refract Surg , vol.25 , pp. 1087-1092
    • Yi, W.M.1    Joo, C.K.2
  • 32
    • 0041704921 scopus 로고    scopus 로고
    • Confocal microscopic evaluation of particles at the corneal flap interface after myopic laser in situ keratomileusis
    • Perez-Gomez I, Efron N. Confocal microscopic evaluation of particles at the corneal flap interface after myopic laser in situ keratomileusis. J Cataract Refract Surg. 2003;29:1373-1377.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1373-1377
    • Perez-Gomez, I.1    Efron, N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.