메뉴 건너뛰기




Volumn 110, Issue 10, 2003, Pages 1931-1934

Comparison of flap thickness reproducibility using microkeratomes with a second motor for advancement

Author keywords

[No Author keywords available]

Indexed keywords

AGE; ARTICLE; CONTROLLED STUDY; CORNEA THICKNESS; CORRELATION ANALYSIS; FLAP THICKNESS; HUMAN; INTERMETHOD COMPARISON; KERATOMETRY; KERATOMILEUSIS; KERATOTOMY; MAJOR CLINICAL STUDY; MICROKERATOMA; PREDICTION; PRIORITY JOURNAL; REPRODUCIBILITY; SURGICAL INSTRUMENT; SURGICAL TECHNIQUE;

EID: 0141848324     PISSN: 01616420     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0161-6420(03)00786-3     Document Type: Article
Times cited : (43)

References (12)
  • 1
    • 0031790753 scopus 로고    scopus 로고
    • Incidence and management of intraoperative and early postoperative complications in 1000 consecutive laser in situ keratomileusis cases
    • Gimbel HV, Penno EE, van Westenbrugge JA, et al. Incidence and management of intraoperative and early postoperative complications in 1000 consecutive laser in situ keratomileusis cases. Ophthalmology 1998;105:1839-46.
    • (1998) Ophthalmology , vol.105 , pp. 1839-1846
    • Gimbel, H.V.1    Penno, E.E.2    Van Westenbrugge, J.A.3
  • 2
    • 0033004614 scopus 로고    scopus 로고
    • Flap complications of lamellar surgery
    • Gimbel HV. Flap complications of lamellar surgery. Am J Ophthalmol 1999;127:202-4.
    • (1999) Am J Ophthalmol , vol.127 , pp. 202-204
    • Gimbel, H.V.1
  • 3
    • 0034904275 scopus 로고    scopus 로고
    • Making sense of refractive surgery in 2001: Why, when, for whom, and by whom?
    • Mannis MJ, Segal WA, Darlington JK. Making sense of refractive surgery in 2001: why, when, for whom, and by whom? Mayo Clin Proc 2001;76:823-9.
    • (2001) Mayo Clin Proc , vol.76 , pp. 823-829
    • Mannis, M.J.1    Segal, W.A.2    Darlington, J.K.3
  • 4
    • 0033659218 scopus 로고    scopus 로고
    • The predictability of corneal flap thickness and tissue laser ablation in laser in situ keratomileusis
    • Durairaj VD, Balentine J, Kouyoumdjian G, et al. The predictability of corneal flap thickness and tissue laser ablation in laser in situ keratomileusis. Ophthalmology 2000;107:2140-3.
    • (2000) Ophthalmology , vol.107 , pp. 2140-2143
    • Durairaj, V.D.1    Balentine, J.2    Kouyoumdjian, G.3
  • 5
    • 0035081949 scopus 로고    scopus 로고
    • Evaluation of the reliability of the Nidek MK-2000 microkeratome for laser in situ keratomileusis
    • Naripthaphan P, Vongthongsri A. Evaluation of the reliability of the Nidek MK-2000 microkeratome for laser in situ keratomileusis. J Refract Surg 2001;17(suppl 2):S255-8.
    • (2001) J Refract Surg , vol.17 , Issue.SUPPL. 2
    • Naripthaphan, P.1    Vongthongsri, A.2
  • 6
    • 0034537228 scopus 로고    scopus 로고
    • Reproducibility of corneal flap thickness in laser in situ keratomileusis using the Hansatome microkeratome
    • Yildirim R, Aras C, Ozdamar A, et al. Reproducibility of corneal flap thickness in laser in situ keratomileusis using the Hansatome microkeratome. J Cataract Refract Surg 2000;26:1729-32.
    • (2000) J Cataract Refract Surg , vol.26 , pp. 1729-1732
    • Yildirim, R.1    Aras, C.2    Ozdamar, A.3
  • 7
    • 0035159975 scopus 로고    scopus 로고
    • Reproducibility of corneal flap thickness in laser in situ keratomileusis using the Hansatome microkeratome
    • Cheng AC, Rao SK, Yu EY, et al. Reproducibility of corneal flap thickness in laser in situ keratomileusis using the Hansatome microkeratome [letter]. J Cataract Refract Surg 2001;27:1712.
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1712
    • Cheng, A.C.1    Rao, S.K.2    Yu, E.Y.3
  • 10
    • 0033956692 scopus 로고    scopus 로고
    • Lower intraoperative flap complication rate with the Hansatome microkeratome compared to the Automated Corneal Shaper
    • Walker MB, Wilson SE. Lower intraoperative flap complication rate with the Hansatome microkeratome compared to the Automated Corneal Shaper. J Refract Surg 2000;16:79-82.
    • (2000) J Refract Surg , vol.16 , pp. 79-82
    • Walker, M.B.1    Wilson, S.E.2
  • 11
    • 0033806345 scopus 로고    scopus 로고
    • Microkeratome complications of laser in situ keratomileusis
    • Tham VM, Maloney RK. Microkeratome complications of laser in situ keratomileusis. Ophthalmology 2000;107:920-4.
    • (2000) Ophthalmology , vol.107 , pp. 920-924
    • Tham, V.M.1    Maloney, R.K.2
  • 12
    • 0037344313 scopus 로고    scopus 로고
    • The precision of flap measurements for laser in situ keratomileusis (LASIK)
    • Flanagan GW, Binder PS. The precision of flap measurements for laser in situ keratomileusis (LASIK). J Refract Surg 2003;19:113-23.
    • (2003) J Refract Surg , vol.19 , pp. 113-123
    • Flanagan, G.W.1    Binder, P.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.