1
-
-
0030476111
-
Quality control procedures for flow cytometric applications in the hematology laboratory
-
D'Hautcourt JL. Quality control procedures for flow cytometric applications in the hematology laboratory. Hematol Cell Ther 1996;38:467-470.
-
(1996)
Hematol Cell Ther
, vol.38
, pp. 467-470
-
-
D'Hautcourt, J.L.1
-
2
-
-
0029988644
-
Quality control study by the French Cytometry Association on flow cytometric DNA content and S-phase fraction (S%). The Association Francaise de Cytometrie
-
D'Hautcourt JL, Spyratos F, Chassevent A. Quality control study by the French Cytometry Association on flow cytometric DNA content and S-phase fraction (S%). The Association Francaise de Cytometrie. Cytometry 1996;26;32-39.
-
(1996)
Cytometry
, vol.26
, pp. 32-39
-
-
D'Hautcourt, J.L.1
Spyratos, F.2
Chassevent, A.3
-
3
-
-
0036488907
-
Dye exclusion artifact in flow cytometers
-
Steen HB, Stokke T. Dye exclusion artifact in flow cytometers. Cytometry 2002;47:200-205.
-
(2002)
Cytometry
, vol.47
, pp. 200-205
-
-
Steen, H.B.1
Stokke, T.2
-
4
-
-
0025351814
-
Quenching of Hoechst 33258 fluorescence in erythroid precursors
-
Stokke T, Holte H, Davies CD, Steen HB, Lie SO. Quenching of Hoechst 33258 fluorescence in erythroid precursors. Cytometry 1990;11:686-690.
-
(1990)
Cytometry
, vol.11
, pp. 686-690
-
-
Stokke, T.1
Holte, H.2
Davies, C.D.3
Steen, H.B.4
Lie, S.O.5
-
5
-
-
0142116238
-
Diffusion dynamics of glycine receptors revealed by single-quantum dot tracking
-
Dahan M, Levi S, Luccardini C, Rostaing P, Riveau B, Triller A. Diffusion dynamics of glycine receptors revealed by single-quantum dot tracking. Science 2003;302:442-445.
-
(2003)
Science
, vol.302
, pp. 442-445
-
-
Dahan, M.1
Levi, S.2
Luccardini, C.3
Rostaing, P.4
Riveau, B.5
Triller, A.6
-
8
-
-
0035503984
-
Spectral compensation for flow cytometry: Visualization artifacts, limitations, and caveats
-
Roederer M. Spectral compensation for flow cytometry: Visualization artifacts, limitations, and caveats. Cytometry 2001;45:194-205.
-
(2001)
Cytometry
, vol.45
, pp. 194-205
-
-
Roederer, M.1
-
9
-
-
1642463402
-
New approaches to fluorescence compensation and visualization of FACS data
-
Tung JW, Parks DR, Moore WA, Herzenberg LA. New approaches to fluorescence compensation and visualization of FACS data. Clin Immunol 2004;110:277-283.
-
(2004)
Clin Immunol
, vol.110
, pp. 277-283
-
-
Tung, J.W.1
Parks, D.R.2
Moore, W.A.3
Herzenberg, L.A.4
-
10
-
-
0034699507
-
A practical approach to multicolor flow cytometry for immunophenotyping
-
Baumgarth N, Roederer M. A practical approach to multicolor flow cytometry for immunophenotyping. J Immunol Methods 2000;243: 77-97.
-
(2000)
J Immunol Methods
, vol.243
, pp. 77-97
-
-
Baumgarth, N.1
Roederer, M.2
-
11
-
-
33846253001
-
Enumeration of peripheral lymphocyte subsets using 6 versus 4 color staining: A clinical evaluation of a new flowcytometer
-
in press
-
Lambert C, Iobagiu C, Genin C. Enumeration of peripheral lymphocyte subsets using 6 versus 4 color staining: A clinical evaluation of a new flowcytometer. Cytometry B Clin Cytom (in press).
-
Cytometry B Clin Cytom
-
-
Lambert, C.1
Iobagiu, C.2
Genin, C.3
-
12
-
-
3042842907
-
Impact of the new Beckman Coulter Cytomics FC 500 5-color flow cytometer on a regional flow cytometry clinical laboratory service
-
Luider J, Cyfra M, Johnson P, Auer I. Impact of the new Beckman Coulter Cytomics FC 500 5-color flow cytometer on a regional flow cytometry clinical laboratory service. Lab Hematol 2004;10:102-108.
-
(2004)
Lab Hematol
, vol.10
, pp. 102-108
-
-
Luider, J.1
Cyfra, M.2
Johnson, P.3
Auer, I.4
-
13
-
-
0025871938
-
Multidimensional flow cytometric blood cell differentiation without erythrocyte lysis
-
Terstappen LW, Johnson D, Mickaels RA, Chen J, Olds G, Hawkins JT, Loken MR, Levin J. Multidimensional flow cytometric blood cell differentiation without erythrocyte lysis. Blood Cells 1991;17:585-602.
-
(1991)
Blood Cells
, vol.17
, pp. 585-602
-
-
Terstappen, L.W.1
Johnson, D.2
Mickaels, R.A.3
Chen, J.4
Olds, G.5
Hawkins, J.T.6
Loken, M.R.7
Levin, J.8
-
14
-
-
0027932340
-
Artifactual staining of monoclonal antibodies in two-color combinations is due to an immunoglobulin in the serum and plasma
-
Nicholson JK, Rao PE, Calvelli T, Stetler-Stevenson M, Browning SW, Yeung L, Marti GE. Artifactual staining of monoclonal antibodies in two-color combinations is due to an immunoglobulin in the serum and plasma. Cytometry 1994;18:140-146.
-
(1994)
Cytometry
, vol.18
, pp. 140-146
-
-
Nicholson, J.K.1
Rao, P.E.2
Calvelli, T.3
Stetler-Stevenson, M.4
Browning, S.W.5
Yeung, L.6
Marti, G.E.7
-
15
-
-
0027161086
-
Double-staining artefact observed in certain individuals during dual-colour immunophenotyping of lymphocytes by flow cytometry
-
Ekong T, Gompels M, Clark C, Parkin J, Pinching A. Double-staining artefact observed in certain individuals during dual-colour immunophenotyping of lymphocytes by flow cytometry. Cytometry 1993; 14:679-684.
-
(1993)
Cytometry
, vol.14
, pp. 679-684
-
-
Ekong, T.1
Gompels, M.2
Clark, C.3
Parkin, J.4
Pinching, A.5
|