메뉴 건너뛰기




Volumn 32, Issue 2, 2007, Pages 182-187

Hangman's fracture: A biomechanical comparison of stabilization techniques

Author keywords

Biomechanics; Cervical spine; Hangman'sfracture; Pars; Pedicle; Spinalinstrumentation

Indexed keywords

ARTICLE; ATLANTOAXIAL FRACTURE DISLOCATION; BIOMECHANICS; CADAVER; CERVICAL SPINE FRACTURE; COMPARATIVE STUDY; CONTROLLED STUDY; FRACTURE FIXATION; HUMAN; HUMAN TISSUE; INTERVERTEBRAL DISKECTOMY; PRIORITY JOURNAL; SPINE FUSION; SPINE MOBILITY; STEREOPHOTOGRAMMETRY; SURGICAL TECHNIQUE;

EID: 33846215881     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/01.brs.0000251917.83529.0b     Document Type: Article
Times cited : (67)

References (19)
  • 2
    • 0019511762 scopus 로고
    • Fractures of the ring of the axis. A classification based on the analysis of 131 cases
    • Effendi B, Roy D, Cornish B, et al. Fractures of the ring of the axis. A classification based on the analysis of 131 cases. J Bone Joint Surg Br 1981;63-B:319-27.
    • (1981) J Bone Joint Surg Br , vol.63-B , pp. 319-327
    • Effendi, B.1    Roy, D.2    Cornish, B.3
  • 3
    • 0026738094 scopus 로고
    • Caspar plate fixation for the treatment of complex hangman's fractures
    • Tuite GF, Papadopoulos SM, Sonntag VK. Caspar plate fixation for the treatment of complex hangman's fractures. Neurosurgery 1992;30:761-4.
    • (1992) Neurosurgery , vol.30 , pp. 761-764
    • Tuite, G.F.1    Papadopoulos, S.M.2    Sonntag, V.K.3
  • 4
    • 0021338354 scopus 로고
    • Treatment of pedicular fractures of the axis. A clinical study and screw fixation technique
    • Borne GM, Bedou GL, Pinaudeau M. Treatment of pedicular fractures of the axis. A clinical study and screw fixation technique. J Neurosurg 1984;60:88-93.
    • (1984) J Neurosurg , vol.60 , pp. 88-93
    • Borne, G.M.1    Bedou, G.L.2    Pinaudeau, M.3
  • 5
    • 13444309246 scopus 로고    scopus 로고
    • Pars screw fixation of a hangman's fracture: Technical case report
    • Bristol R, Henn JS, Dickman CA. Pars screw fixation of a hangman's fracture: Technical case report. Neurosurgery 2005;56:E204.
    • (2005) Neurosurgery , vol.56
    • Bristol, R.1    Henn, J.S.2    Dickman, C.A.3
  • 6
    • 0032031314 scopus 로고    scopus 로고
    • Hangman's fracture: Arguments in favor of surgical therapy for Type II and III according to Edwards and Levine
    • Verheggen R, Jansen J. Hangman's fracture: Arguments in favor of surgical therapy for Type II and III according to Edwards and Levine. Surg Neurol 1998;49:253-61.
    • (1998) Surg Neurol , vol.49 , pp. 253-261
    • Verheggen, R.1    Jansen, J.2
  • 7
    • 0024456864 scopus 로고
    • Surgical management of cervical spine injuries
    • Karimi-Nejad A. Surgical management of cervical spine injuries. Neurosurg Rev 1989;12(suppl 1):525-35.
    • (1989) Neurosurg Rev , vol.12 , Issue.SUPPL. 1 , pp. 525-535
    • Karimi-Nejad, A.1
  • 8
    • 0037347296 scopus 로고    scopus 로고
    • Craniovertebral junction fixation with transarticular screws: Biomechanical analysis of a novel technique
    • Gonzalez LF, Crawford NR, Chamberlain RH, et al. Craniovertebral junction fixation with transarticular screws: Biomechanical analysis of a novel technique. J Neurosurg 2003;98:202-9.
    • (2003) J Neurosurg , vol.98 , pp. 202-209
    • Gonzalez, L.F.1    Crawford, N.R.2    Chamberlain, R.H.3
  • 9
    • 0032902986 scopus 로고    scopus 로고
    • A biomechanical evaluation of occipitocervical instrumentation: Screw compared with wire fixation
    • Hurlbert RJ, Crawford NR, Choi WG, et al. A biomechanical evaluation of occipitocervical instrumentation: Screw compared with wire fixation. J Neurosurg 1999;90:84-90.
    • (1999) J Neurosurg , vol.90 , pp. 84-90
    • Hurlbert, R.J.1    Crawford, N.R.2    Choi, W.G.3
  • 10
    • 0032530291 scopus 로고    scopus 로고
    • Biomechanical comparison of C1-C2 posterior fixations. Cable, graft, and screw combinations
    • Naderi S, Crawford NR, Song GS, et al. Biomechanical comparison of C1-C2 posterior fixations. Cable, graft, and screw combinations. Spine 1998;23:1946-55.
    • (1998) Spine , vol.23 , pp. 1946-1955
    • Naderi, S.1    Crawford, N.R.2    Song, G.S.3
  • 11
    • 0029096617 scopus 로고
    • An apparatus for applying pure nonconstraining moments to spine segments in vitro
    • Crawford NR, Brantley AG, Dickman CA, et al. An apparatus for applying pure nonconstraining moments to spine segments in vitro. Spine 1995;20:2097-100.
    • (1995) Spine , vol.20 , pp. 2097-2100
    • Crawford, N.R.1    Brantley, A.G.2    Dickman, C.A.3
  • 12
    • 0030996697 scopus 로고    scopus 로고
    • Construction of local vertebral coordinate systems using a digitizing probe. Technical note
    • Crawford NR, Dickman CA. Construction of local vertebral coordinate systems using a digitizing probe. Technical note. Spine 1997;22:559-63.
    • (1997) Spine , vol.22 , pp. 559-563
    • Crawford, N.R.1    Dickman, C.A.2
  • 14
    • 0022354031 scopus 로고
    • Biomechanical time-tolerance of fresh cadaveric human spine specimens
    • Panjabi MM, Krag M, Summers D, et al. Biomechanical time-tolerance of fresh cadaveric human spine specimens. J Orthop Res 1985;3:292-300.
    • (1985) J Orthop Res , vol.3 , pp. 292-300
    • Panjabi, M.M.1    Krag, M.2    Summers, D.3
  • 15
    • 0033214753 scopus 로고    scopus 로고
    • The anatomic relation of lateral mass screws to the spinal nerves. A comparison of the Magerl, Anderson, and An techniques
    • Xu R, Haman SP, Ebraheim NA, et al. The anatomic relation of lateral mass screws to the spinal nerves. A comparison of the Magerl, Anderson, and An techniques. Spine 1999;24:2057-61.
    • (1999) Spine , vol.24 , pp. 2057-2061
    • Xu, R.1    Haman, S.P.2    Ebraheim, N.A.3
  • 16
    • 0031726313 scopus 로고    scopus 로고
    • The spinal lax zone and neutral zone: Measurement techniques and parameter comparisons
    • Crawford NR, Peles JD, Dickman CA. The spinal lax zone and neutral zone: Measurement techniques and parameter comparisons. J Spinal Disord 1998;11:416-29.
    • (1998) J Spinal Disord , vol.11 , pp. 416-429
    • Crawford, N.R.1    Peles, J.D.2    Dickman, C.A.3
  • 18
    • 0033833678 scopus 로고    scopus 로고
    • Traumatic spondylolisthesis of the axis: Treatment rationale based on the stability of the different fracture types
    • Muller EJ, Wick M, Muhr G. Traumatic spondylolisthesis of the axis: Treatment rationale based on the stability of the different fracture types. Eur Spine J 2000;9:123-8.
    • (2000) Eur Spine J , vol.9 , pp. 123-128
    • Muller, E.J.1    Wick, M.2    Muhr, G.3
  • 19
    • 0033779047 scopus 로고    scopus 로고
    • CT-guided internal fixation of a hangman's fracture
    • Taller S, Suchomel P, Lukas R, et al. CT-guided internal fixation of a hangman's fracture. Eur Spine J 2000;9:393-7.
    • (2000) Eur Spine J , vol.9 , pp. 393-397
    • Taller, S.1    Suchomel, P.2    Lukas, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.