메뉴 건너뛰기




Volumn 23, Issue 1, 2007, Pages 45-49

Comparison of experimental microvascular end-to-end anastomosis via VCS®-Clips versus conventional suture technique in an animal model

Author keywords

Anastomosis; Vascular microsurgery; VCS Clip

Indexed keywords

ABDOMINAL AORTA; ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; AORTA THROMBOSIS; ARTERY INTIMA PROLIFERATION; ARTICLE; BLOOD VESSEL SHUNT; CLIP; CONTROLLED STUDY; ECHOGRAPHY; END TO END ANASTOMOSIS; FOREIGN BODY REACTION; HISTOPATHOLOGY; INFLAMMATION; INTERMETHOD COMPARISON; MICROANGIOGRAPHY; MICROVASCULAR SURGERY; NONHUMAN; POSTOPERATIVE COMPLICATION; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; RAT; SURGICAL INSTRUMENT; SUTURING METHOD; TISSUE NECROSIS; TUNICA MEDIA; VASCULAR NECROSIS;

EID: 33846185163     PISSN: 0743684X     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2006-958702     Document Type: Article
Times cited : (13)

References (11)
  • 1
    • 0030738739 scopus 로고    scopus 로고
    • Scanning electron microscopic analysis of the stapled microvascular anastomosis in the rabbit
    • Boeckx WD, Darius O, van den Hof B, van Holder C. Scanning electron microscopic analysis of the stapled microvascular anastomosis in the rabbit. Ann Thorac Surg 1997;63:128-134
    • (1997) Ann Thorac Surg , vol.63 , pp. 128-134
    • Boeckx, W.D.1    Darius, O.2    van den Hof, B.3    van Holder, C.4
  • 2
    • 0035092397 scopus 로고    scopus 로고
    • Can minimal arterial aggressions using non-penetrating mechanical clip suture prevent myo-intimal hyperplasia? Preliminary results
    • Ducasse E, Basseau F, Puppinck P, Baquey C. Can minimal arterial aggressions using non-penetrating mechanical clip suture prevent myo-intimal hyperplasia? Preliminary results. J Mal Vasc 2001;26:50-54
    • (2001) J Mal Vasc , vol.26 , pp. 50-54
    • Ducasse, E.1    Basseau, F.2    Puppinck, P.3    Baquey, C.4
  • 3
    • 0031916025 scopus 로고    scopus 로고
    • VCS microclip anastomosis on blood vessels of less than 2 millimeters in diameter. Preliminary experimental study in the rat
    • Gerbault O, Arrouvel C, Servant JM, Revol M, Banzet P. VCS microclip anastomosis on blood vessels of less than 2 millimeters in diameter. Preliminary experimental study in the rat. Ann Chir Plast Esthet 1998;43:27-39
    • (1998) Ann Chir Plast Esthet , vol.43 , pp. 27-39
    • Gerbault, O.1    Arrouvel, C.2    Servant, J.M.3    Revol, M.4    Banzet, P.5
  • 4
    • 0034098695 scopus 로고    scopus 로고
    • Stapled versus hand-sewn vascular anastomoses. An experimental study in the rabbit
    • Pauli S, Lauwers P: Stapled versus hand-sewn vascular anastomoses. An experimental study in the rabbit. Eur Surg Res 2000;32:39-42
    • (2000) Eur Surg Res , vol.32 , pp. 39-42
    • Pauli, S.1    Lauwers, P.2
  • 7
    • 0026676092 scopus 로고
    • Vascular anatomy of the gastric tube used for esophageal reconstruction
    • Liebermann-Meffert DMI, Meier R, Siewert RJ. Vascular anatomy of the gastric tube used for esophageal reconstruction. Ann Thorac Surg 1992;54:1110-1115
    • (1992) Ann Thorac Surg , vol.54 , pp. 1110-1115
    • Liebermann-Meffert, D.M.I.1    Meier, R.2    Siewert, R.J.3
  • 9
    • 0033638001 scopus 로고    scopus 로고
    • Biliary end-to-end anastomosis with extramucosal titanium clips. Initial results with a new technique
    • Birth M, Geberding J, Markert U, Wohlschlager C, Brugmans F, Bruch HP. Biliary end-to-end anastomosis with extramucosal titanium clips. Initial results with a new technique. Zentralbl Chir 2000;125:990-996
    • (2000) Zentralbl Chir , vol.125 , pp. 990-996
    • Birth, M.1    Geberding, J.2    Markert, U.3    Wohlschlager, C.4    Brugmans, F.5    Bruch, H.P.6
  • 10
    • 0031933249 scopus 로고    scopus 로고
    • Carotid arteriotomy using a vascular clip system
    • Findlay JM, Megyesi JF. Carotid arteriotomy using a vascular clip system. Neurosurgery 1998;42:550-553
    • (1998) Neurosurgery , vol.42 , pp. 550-553
    • Findlay, J.M.1    Megyesi, J.F.2
  • 11
    • 0032901242 scopus 로고    scopus 로고
    • Clinical application of a nonpenetrating microvascular stapling device for vascularized free tissue transfer
    • Yamamoto N, Nakai H, Satoh Y, Oshima Y. Clinical application of a nonpenetrating microvascular stapling device for vascularized free tissue transfer. Ann Plast Surg 1999;42:49-55
    • (1999) Ann Plast Surg , vol.42 , pp. 49-55
    • Yamamoto, N.1    Nakai, H.2    Satoh, Y.3    Oshima, Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.