메뉴 건너뛰기




Volumn 42, Issue 1, 1999, Pages 49-55

Clinical application of a nonpenetrating microvascular stapling device for vascularized free tissue transfer

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANASTOMOSIS; ARTICLE; CLINICAL ARTICLE; FEMALE; FREE TISSUE GRAFT; HUMAN; MALE; PRIORITY JOURNAL; STAPLER; WOUND INFECTION;

EID: 0032901242     PISSN: 01487043     EISSN: None     Source Type: Journal    
DOI: 10.1097/00000637-199901000-00009     Document Type: Article
Times cited : (23)

References (13)
  • 1
    • 0021723338 scopus 로고
    • An anastomotic device for microvascular surgery: Evolution
    • Daniel RK, Lindman D, Olding M, et al. An anastomotic device for microvascular surgery: evolution. Ann Plast Surg 1984;13:402-411
    • (1984) Ann Plast Surg , vol.13 , pp. 402-411
    • Daniel, R.K.1    Lindman, D.2    Olding, M.3
  • 2
    • 0023129585 scopus 로고
    • A technique for non-suture vascular anastomosis
    • Gentili F, Lougheed W, Yoshijima S, et al. A technique for non-suture vascular anastomosis. Can J Neurol Sci 1987; 14:92-95
    • (1987) Can J Neurol Sci , vol.14 , pp. 92-95
    • Gentili, F.1    Lougheed, W.2    Yoshijima, S.3
  • 3
    • 0018225192 scopus 로고
    • A new easier way to anastomose microvessels
    • Lauritzen C. A new easier way to anastomose microvessels. Scand J Plast Reconstr Surg 1978;12:291-294
    • (1978) Scand J Plast Reconstr Surg , vol.12 , pp. 291-294
    • Lauritzen, C.1
  • 4
    • 0023696235 scopus 로고
    • Vessel anastomosis using a venous cuff and two sutures: An experimental study in rat femoral and epigastric vessels
    • Nakayama Y, Soeda Y, Kiyosawa T. Vessel anastomosis using a venous cuff and two sutures: an experimental study in rat femoral and epigastric vessels. J Reconstr Microsurg 1988;4:335-339
    • (1988) J Reconstr Microsurg , vol.4 , pp. 335-339
    • Nakayama, Y.1    Soeda, Y.2    Kiyosawa, T.3
  • 5
    • 0022830388 scopus 로고
    • The UNILINK instrument system for fast and safe microvascular anastomosis
    • Östrup LT, Berggren A. The UNILINK instrument system for fast and safe microvascular anastomosis. Ann Plast Surg 1986;17:521-525
    • (1986) Ann Plast Surg , vol.17 , pp. 521-525
    • Östrup, L.T.1    Berggren, A.2
  • 6
    • 0030738739 scopus 로고    scopus 로고
    • Scanning electron microscopic analysis of the stapled microvascular anastomosis in the rabbit
    • Boeckx WD, Darius O, Van Den Hof B, et al. Scanning electron microscopic analysis of the stapled microvascular anastomosis in the rabbit. Ann Thorac Surg 1997; 63(Suppl.):128-134
    • (1997) Ann Thorac Surg , vol.63 , Issue.SUPPL. , pp. 128-134
    • Boeckx, W.D.1    Darius, O.2    Van Den Hof, B.3
  • 7
    • 0027085680 scopus 로고
    • A new method for microvascular anastomosis: Report of experimental and clinical research
    • Kirsch WM, Zhu YM, Hardesty RA, et al. A new method for microvascular anastomosis: report of experimental and clinical research. Am Surg 1992;58:722-727
    • (1992) Am Surg , vol.58 , pp. 722-727
    • Kirsch, W.M.1    Zhu, Y.M.2    Hardesty, R.A.3
  • 8
    • 0007603764 scopus 로고
    • A multi-centered controlled clinical trial comparing clips to suture for construction of vascular access sites for hemodialysis
    • Kyoto, Japan. September 10-14, abstract nos. 136, 137
    • Hammond J, Kirsch WM, Wahlstrom PGE, et al. A multi-centered controlled clinical trial comparing clips to suture for construction of vascular access sites for hemodialysis. Presented at the 22nd World Congress of the International Society for Cardiovascular Surgery. Kyoto, Japan. September 10-14, 1995 [abstract nos. 136, 137]
    • (1995) 22nd World Congress of the International Society for Cardiovascular Surgery
    • Hammond, J.1    Kirsch, W.M.2    Wahlstrom, P.G.E.3
  • 9
    • 0005391735 scopus 로고    scopus 로고
    • Use of vascular staple device for the creation of AV fistulae and bridge grafts for hemodialysis
    • Schild AF. Use of vascular staple device for the creation of AV fistulae and bridge grafts for hemodialysis. Vasc Access Hemodialysis 1997;5:95-102
    • (1997) Vasc Access Hemodialysis , vol.5 , pp. 95-102
    • Schild, A.F.1
  • 10
    • 0020047098 scopus 로고
    • Use of a continuous suture for back wall repair of end-to-end or end-to-side anastomosis
    • Harashina T. Use of a continuous suture for back wall repair of end-to-end or end-to-side anastomosis. Plast Reconstr Surg 1982;69:139-144
    • (1982) Plast Reconstr Surg , vol.69 , pp. 139-144
    • Harashina, T.1
  • 12
    • 0025106557 scopus 로고
    • Wound healing at the site of microvascular anastomosis
    • Isogai H, Kurozumi N, Kamiishi H, et al. Wound healing at the site of microvascular anastomosis. Microsurgery 1990; 11:40-46
    • (1990) Microsurgery , vol.11 , pp. 40-46
    • Isogai, H.1    Kurozumi, N.2    Kamiishi, H.3
  • 13
    • 0017263074 scopus 로고
    • A scanning electron microscopic study of microvascular anastomoses
    • Servant JM, Ikuta Y, Harada Y. A scanning electron microscopic study of microvascular anastomoses. Plast Reconstr Surg 1976;57:608-613
    • (1976) Plast Reconstr Surg , vol.57 , pp. 608-613
    • Servant, J.M.1    Ikuta, Y.2    Harada, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.