메뉴 건너뛰기




Volumn 25, Issue 8, 2005, Pages 17-

On-line monitoring techniques for 110 kV and above XLPE cable

Author keywords

Insulation; On line monitoring; Power cable; XLPE

Indexed keywords

ELECTRIC CABLES; ELECTRIC GROUNDING; ELECTRIC INSULATION; NETWORKS (CIRCUITS); ONLINE SYSTEMS;

EID: 33846128731     PISSN: 10066047     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (21)

References (12)
  • 1
    • 0023145485 scopus 로고
    • Development of new diagnostic method for hot-line XLPE cables with water trees[J]
    • OONISHI H,URANO F,MOCHIZUKI T,et al. Development of new diagnostic method for hot-line XLPE cables with water trees[J]. IEEE Trans, on Power Delivery, 1987 ,2(1):1-7.
    • (1987) IEEE Trans, on Power Delivery , vol.2 , Issue.1 , pp. 1-7
    • Oonishi, H.1    Urano, F.2    Mochizuki, T.3
  • 2
    • 34250826015 scopus 로고
    • Development of a hot-line diagnostic method for XLPE cables and the measurement results[J]
    • NAKAJIMA A. Development of a hot-line diagnostic method for XLPE cables and the measurement results[J]. IEEE Trans. on Power Delivery, 1989,4(2):857-862.
    • (1989) IEEE Trans. on Power Delivery , vol.4 , Issue.2 , pp. 857-862
    • Nakajima, A.1
  • 7
    • 33846139006 scopus 로고    scopus 로고
    • Research on the anti-interference technique used in DC method of XLPE cable on-line detecting[J]
    • ZHENG Xiao-quan,TU De-min. Research on the anti-interference technique used in DC method of XLPE cable on-line detecting[J]. Electric Wire&Cable,1998,(4):33 -35.
    • (1998) Electric Wire&Cable , Issue.4 , pp. 33-35
    • Zheng, X.-Q.1    Tu, D.-M.2
  • 8
    • 33846160180 scopus 로고    scopus 로고
    • The application of compensating potential method in XLPE on-line detection[J]
    • ZHENG Xiao-quan,TU De-min. The application of compensating potential method in XLPE on-line detection[J]. High Voltage Engineering, 1998,24(3):28-30.
    • (1998) High Voltage Engineering , vol.24 , Issue.3 , pp. 28-30
    • Zheng, X.-Q.1    Tu, D.-M.2
  • 9
    • 33846173620 scopus 로고    scopus 로고
    • Factors influening the results of the on-line diagnosis of XLPE cable insulation by DC measurement and solutions[J]
    • ZHENG Xiao-quan. Factors influening the results of the on-line diagnosis of XLPE cable insulation by DC measurement and solutions[J]. Electric Wire & Cable, 2000, (5):28-32.
    • (2000) Electric Wire & Cable , Issue.5 , pp. 28-32
    • Zheng, X.-Q.1
  • 10
    • 14744288973 scopus 로고    scopus 로고
    • Simulation of online monitoring of power cable insulation using grounding current method[J]
    • 35
    • DUAN Jian-dong,CHEN Tian-xiang,ZHANG Bao-bui. Simulation of online monitoring of power cable insulation using grounding current method[J]. High Voltage Apparatus , 2005,41 (1):29-31,35.
    • (2005) High Voltage Apparatus , vol.41 , Issue.1 , pp. 29-31
    • Duan, J.-D.1    Chen, T.-X.2    Zhang, B.-B.3
  • 11
    • 27944508585 scopus 로고    scopus 로고
    • Application of fiber optic distributed temperature sensor to fault detection of XLPE insulated underground cable [J]
    • 42
    • ZHANG Xiao-hong,JIANG Xiong-wei,WANG Zhen-hua, et al. Application of fiber optic distributed temperature sensor to fault detection of XLPE insulated underground cable [J]. Power System Technology, 1999,23 (12):36-38,42.
    • (1999) Power System Technology , vol.23 , Issue.12 , pp. 36-38
    • Zhang, X.-H.1    Jiang, X.-W.2    Wang, Z.-H.3
  • 12
    • 33846159498 scopus 로고    scopus 로고
    • Monitoring for power cable fire and development of early fire warning system [J]
    • LI Yan-qiu,CAO Zhong-zhong,JIN Tao. Monitoring for power cable fire and development of early fire warning system [J]. North China Electric Power,2001, (2):23 -24.
    • (2001) North China Electric Power , Issue.2 , pp. 23-24
    • Li, Y.-Q.1    Cao, Z.-Z.2    Jin, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.