Volumn , Issue , 2004, Pages 454-457

Continuous on-line monitoring of partial discharges in high voltage cables

Author keywords

[No Author keywords available]

Indexed keywords

CAPACITANCE; DATA ACQUISITION; DATA COMMUNICATION SYSTEMS; ELECTRIC CABLES; ELECTRIC CONNECTORS; ELECTRIC POTENTIAL; ELECTROOPTICAL DEVICES; LITHIUM NIOBATE; MODULATORS; ONLINE SYSTEMS; REMOTE CONTROL;

EID: 14844291380     PISSN: 01642006     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (20)

References (12)
  • 1
    • 14844313377 scopus 로고    scopus 로고
    • Partial discharge on-line monitoring for HV cable systems using electrooptic modulators
    • accepted for publication in
    • Tian Y., P. L Lewin, D. Pommerenke, J. S. Wilkinson and S. J. Sutton, "Partial Discharge On-line Monitoring for HV Cable Systems Using Electrooptic Modulators", accepted for publication in IEEE Trans DEI.
    • IEEE Trans DEI
    • Tian, Y.1    Lewin, P.L.2    Pommerenke, D.3    Wilkinson, J.S.4    Sutton, S.J.5
  • 3
    • 0032045622 scopus 로고    scopus 로고
    • On-line partial discharge detection in cables
    • Ahmed, N. H. and N. N. Srinivas, "On-line Partial Discharge Detection in Cables", IEEE Trans. DEI, Vol. 5, pp. 181-188, 1998
    • (1998) IEEE Trans. DEI , vol.5 , pp. 181-188
    • Ahmed, N.H.1    Srinivas, N.N.2
  • 6
    • 0029289678 scopus 로고
    • Application of advanced after-laying test to long-distance 275 kV XLPE cable lines
    • April
    • Ota H., M. Ichihara et al, "Application of advanced after-laying test to long-distance 275 kV XLPE cable lines", IEEE Trans. Power Delivery, Vol. 10, No. 2, pp. 567-579, April 1995
    • (1995) IEEE Trans. Power Delivery , vol.10 , Issue.2 , pp. 567-579
    • Ota, H.1    Ichihara, M.2
  • 8
    • 14844292201 scopus 로고    scopus 로고
    • OHT partial discharge detection instrument - Functional description
    • Ontario Hydro, "OHT Partial Discharge Detection Instrument - Functional Description", user manual, 1997
    • (1997) User Manual
    • Hydro, O.1
  • 9
    • 0036693440 scopus 로고    scopus 로고
    • Comparison of on-line partial discharge detection methods for HV cable joints
    • August
    • Tian Y., P. L. Lewin, A. E. Davies, S. J. Sutton, S. G. Swingler, "Comparison of On-line Partial Discharge Detection Methods for HV Cable Joints", IEEE Trans. DEI, Vol. 9, No. 4, pp. 604-615, August 2002
    • (2002) IEEE Trans. DEI , vol.9 , Issue.4 , pp. 604-615
    • Tian, Y.1    Lewin, P.L.2    Davies, A.E.3    Sutton, S.J.4    Swingler, S.G.5
  • 10
    • 0037732574 scopus 로고    scopus 로고
    • Partial discharge detection in cables using VHF capacitive couplers
    • April
    • Tian Y., P. L. Lewin, A. E. Davies, S. J. Sutton, S. G. Swingler, "Partial Discharge Detection in Cables using VHF Capacitive Couplers", IEEE Trans. DEI, Vol. 10, No. 2, pp. 343-353, April 2003
    • (2003) IEEE Trans. DEI , vol.10 , Issue.2 , pp. 343-353
    • Tian, Y.1    Lewin, P.L.2    Davies, A.E.3    Sutton, S.J.4    Swingler, S.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.