메뉴 건너뛰기




Volumn 17, Issue 1, 2007, Pages 265-271

Evaluation of various image reconstruction parameters in lower extremity stents using multidetector-row CT angiography: Initial findings

Author keywords

CTangiography; Digital subtraction angiography; Lower extremity; Multidetector row CT; Stent

Indexed keywords

IMERON 400; IOMEPROL; IOPROMIDE; UNCLASSIFIED DRUG;

EID: 33846109131     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-006-0315-1     Document Type: Article
Times cited : (13)

References (37)
  • 1
    • 0025800329 scopus 로고
    • Cytokines and growth factors positively and negatively regulate interstitial collagen gene expression in human vascular smooth muscle cells
    • Amento EP, Ehsani N, Palmer H, Libby P (1991) Cytokines and growth factors positively and negatively regulate interstitial collagen gene expression in human vascular smooth muscle cells. Arterioscler Thromb 11:1223-1230
    • (1991) Arterioscler Thromb , vol.11 , pp. 1223-1230
    • Amento, E.P.1    Ehsani, N.2    Palmer, H.3    Libby, P.4
  • 5
    • 0032827388 scopus 로고    scopus 로고
    • The use of duplex ultrasound arterial mapping as an alternative to conventional arteriography for primary and secondary infrapopliteal bypasses
    • Ascher E, Mazzariol F, Hingorani A, Saller-Cunha S, Gade P (1999) The use of duplex ultrasound arterial mapping as an alternative to conventional arteriography for primary and secondary infrapopliteal bypasses. Am J Surg 178:162-165
    • (1999) Am J Surg , vol.178 , pp. 162-165
    • Ascher, E.1    Mazzariol, F.2    Hingorani, A.3    Saller-Cunha, S.4    Gade, P.5
  • 8
    • 0032811088 scopus 로고    scopus 로고
    • Iliofemoral arterial occlusive disease: Contrast-enhanced MR angiography for preinterventional evaluation and follow-up after stent placement
    • Link J, Steffens J, Brossmann J, Gaessner J, Hackethal S, Heller M (1999) Iliofemoral arterial occlusive disease: Contrast-enhanced MR angiography for preinterventional evaluation and follow-up after stent placement. Radiology 212:371-377
    • (1999) Radiology , vol.212 , pp. 371-377
    • Link, J.1    Steffens, J.2    Brossmann, J.3    Gaessner, J.4    Hackethal, S.5    Heller, M.6
  • 9
    • 0033014248 scopus 로고    scopus 로고
    • Aotoiliac and lower extremity arteries: Comparison of three-dimensional dynamic contrast-enhanced subtraction MR angiography and conventional angiography
    • Sueyoshi E, Sakamoto I, Matsuoka Y, Ogawa Y, Hayashi H, Hashmi R, Hayashi K (1999) Aotoiliac and lower extremity arteries: Comparison of three-dimensional dynamic contrast-enhanced subtraction MR angiography and conventional angiography. Radiology 210:683-686
    • (1999) Radiology , vol.210 , pp. 683-686
    • Sueyoshi, E.1    Sakamoto, I.2    Matsuoka, Y.3    Ogawa, Y.4    Hayashi, H.5    Hashmi, R.6    Hayashi, K.7
  • 10
    • 0036783785 scopus 로고    scopus 로고
    • Peripheral vascular occlusive disease: Evaluation with contrast-enhanced moving-bed MR angiography versus digital subtraction angiography in 106 patients
    • Loewe C, Schoder M, Rand T, Hoffmann U, Sailer J, Kos T, Lammer J, Thurher S (2002) Peripheral vascular occlusive disease: Evaluation with contrast-enhanced moving-bed MR angiography versus digital subtraction angiography in 106 patients. AJR Am J Roentgenol 179:1013-1021
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 1013-1021
    • Loewe, C.1    Schoder, M.2    Rand, T.3    Hoffmann, U.4    Sailer, J.5    Kos, T.6    Lammer, J.7    Thurher, S.8
  • 11
    • 0038118634 scopus 로고    scopus 로고
    • CT angiography of the thoracic aorta
    • Rubin GD (2003) CT angiography of the thoracic aorta. Semin Roentgenol 38:115-134
    • (2003) Semin Roentgenol , vol.38 , pp. 115-134
    • Rubin, G.D.1
  • 12
    • 2442522614 scopus 로고    scopus 로고
    • Multidetector row CT angiography of the abdominal aorta and lower extremities in patients with peripheral arterial occlusive disease: Diagnostic accuracy and interobserver agreement
    • Romano M, Mainenti PP, Imbriaco M, Amato B, Markabaoui K, Tamburrini O, Salvatore M (2004) Multidetector row CT angiography of the abdominal aorta and lower extremities in patients with peripheral arterial occlusive disease: Diagnostic accuracy and interobserver agreement. Eur J Radiol 50:303-308
    • (2004) Eur J Radiol , vol.50 , pp. 303-308
    • Romano, M.1    Mainenti, P.P.2    Imbriaco, M.3    Amato, B.4    Markabaoui, K.5    Tamburrini, O.6    Salvatore, M.7
  • 15
    • 0034543124 scopus 로고    scopus 로고
    • Stent appearance at contrast-enhanced MR angiography: In vitro examination with 14 stents
    • Lenhart M, Volk M, Manke C, Nitz WR, Strotzer M, Feuerbach S, Link J (2000) Stent appearance at contrast-enhanced MR angiography: In vitro examination with 14 stents. Radiology 217:173-178
    • (2000) Radiology , vol.217 , pp. 173-178
    • Lenhart, M.1    Volk, M.2    Manke, C.3    Nitz, W.R.4    Strotzer, M.5    Feuerbach, S.6    Link, J.7
  • 16
    • 0035067940 scopus 로고    scopus 로고
    • In vitro evaluation of intravascular stent artifacts in three-dimensional MR angiography
    • Maintz D, Kugel H, Schellhammer F, Landwehr P (2001) In vitro evaluation of intravascular stent artifacts in three-dimensional MR angiography. Invest Radiol 36:218-224
    • (2001) Invest Radiol , vol.36 , pp. 218-224
    • Maintz, D.1    Kugel, H.2    Schellhammer, F.3    Landwehr, P.4
  • 18
    • 0035660731 scopus 로고    scopus 로고
    • Multislice CT angiography of the iliac arteries in the presence of various stents: In vitro evaluation of artifacts and lumen visibility
    • Maintz D, Fischbach R, Juergens KU, AllkemperT, Wessling J, Heindel W (2001) Multislice CT angiography of the iliac arteries in the presence of various stents: In vitro evaluation of artifacts and lumen visibility. Invest Radiol 36:699-704
    • (2001) Invest Radiol , vol.36 , pp. 699-704
    • Maintz, D.1    Fischbach, R.2    Juergens, K.U.3    Allkemper, T.4    Wessling, J.5    Heindel, W.6
  • 19
    • 0033827919 scopus 로고    scopus 로고
    • Utility of CT angiography and MR angiography for the follow-up of experimental aneurysms treated with stents or Guglielmi detachable coils
    • Masaryk AM, Frayne R, Unal O, Rappe AH, Strother CM (2000) Utility of CT angiography and MR angiography for the follow-up of experimental aneurysms treated with stents or Guglielmi detachable coils. AJNR Am J Neuroradiol 21:1523-1531
    • (2000) AJNR Am J Neuroradiol , vol.21 , pp. 1523-1531
    • Masaryk, A.M.1    Frayne, R.2    Unal, O.3    Rappe, A.H.4    Strother, C.M.5
  • 20
    • 0033994702 scopus 로고    scopus 로고
    • Usefulness of CT angiography with volume rendering after carotid angioplasty and stenting
    • Leclerc X, Gauvrit JY, Pruvo JP (2000) Usefulness of CT angiography with volume rendering after carotid angioplasty and stenting. AJR Am J Roentgenol 174:820-822
    • (2000) AJR Am J Roentgenol , vol.174 , pp. 820-822
    • Leclerc, X.1    Gauvrit, J.Y.2    Pruvo, J.P.3
  • 21
    • 4644360295 scopus 로고    scopus 로고
    • Coronary artery stent patency assessed with in-stent contrast enhancement measured at multi-detector row CT angiography: Initial experience
    • Hong C, Chrysant GS, Woodard PK, Bae KT (2004) Coronary artery stent patency assessed with in-stent contrast enhancement measured at multi-detector row CT angiography: Initial experience. Radiology 233:286-291
    • (2004) Radiology , vol.233 , pp. 286-291
    • Hong, C.1    Chrysant, G.S.2    Woodard, P.K.3    Bae, K.T.4
  • 23
    • 1942501529 scopus 로고    scopus 로고
    • Measurement of cascular diameter in vitro by automated software for CT angiography: Effect of inner diameter, density of contrast medium, and convolution kernel
    • Suzuki S, Furui S, Kaminaga T, Yamauchi T (2004) Measurement of cascular diameter in vitro by automated software for CT angiography: Effect of inner diameter, density of contrast medium, and convolution kernel. AJR Am J Roentgenol 182:1313-1317
    • (2004) AJR Am J Roentgenol , vol.182 , pp. 1313-1317
    • Suzuki, S.1    Furui, S.2    Kaminaga, T.3    Yamauchi, T.4
  • 26
    • 0033399213 scopus 로고    scopus 로고
    • Duplex imaging of lower extremity bypasses, angioplasties and stents
    • Roth SM, Bandyk DF (1999) Duplex imaging of lower extremity bypasses, angioplasties and stents. Semi Vasc Sug 12:275-284
    • (1999) Semi Vasc Sug , vol.12 , pp. 275-284
    • Roth, S.M.1    Bandyk, D.F.2
  • 27
    • 0345298274 scopus 로고    scopus 로고
    • Plain and covered stent-grafts: In vitro evaluation of characteristics at three-dimensional MR angiography
    • Hilfiker P, Quick H, Debatin J (1999) Plain and covered stent-grafts: In vitro evaluation of characteristics at three-dimensional MR angiography. Radiology 211:693-697
    • (1999) Radiology , vol.211 , pp. 693-697
    • Hilfiker, P.1    Quick, H.2    Debatin, J.3
  • 28
    • 0036839063 scopus 로고    scopus 로고
    • Revealing in-stent stenoses of the iliac arteries: Comparison of multidetector CT with MR angiography and digital radiographic angiography in a phantom model
    • Maintz D, Tombach Bernd, Juergens KU, Weigel S, Heindel W, Fischbach R (2002) Revealing in-stent stenoses of the iliac arteries: Comparison of multidetector CT with MR angiography and digital radiographic angiography in a phantom model. AJR Am J Roentgenol 179:1319-1322
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 1319-1322
    • Maintz, D.1    Tombach, B.2    Juergens, K.U.3    Weigel, S.4    Heindel, W.5    Fischbach, R.6
  • 29
    • 0642303151 scopus 로고    scopus 로고
    • Images in cardiovascular medicine. Neointimal hyperplasia in carotid stent detected with multislice computed tomography
    • Cademartiri F, Mollet N, Nieman K, Krestin GP, deFeyter PJ (2003) Images in cardiovascular medicine. Neointimal hyperplasia in carotid stent detected with multislice computed tomography. Circulation 108:147
    • (2003) Circulation , vol.108 , pp. 147
    • Cademartiri, F.1    Mollet, N.2    Nieman, K.3    Krestin, G.P.4    de Feyter, P.J.5
  • 30
    • 0141855303 scopus 로고    scopus 로고
    • Small-vessel stents for intracranial angioplasty: In vitro comparison of different stent designs and sizes by using CT angiography
    • Hahnel S, Tossbach M, Braun C, Heiland S, Knauth M, Sartor K, Hartmann M (2003) Small-vessel stents for intracranial angioplasty: In vitro comparison of different stent designs and sizes by using CT angiography. AJNR Am J Neuroradiol 24:1512-1516
    • (2003) AJNR Am J Neuroradiol , vol.24 , pp. 1512-1516
    • Hahnel, S.1    Tossbach, M.2    Braun, C.3    Heiland, S.4    Knauth, M.5    Sartor, K.6    Hartmann, M.7
  • 31
    • 0038757591 scopus 로고    scopus 로고
    • Imaging of coronary artery stents using multislice computed tomography: In vitro evaluation
    • Maintz D, Juergens KU, Wichert T, Grude M, Heindel W, Fischbach R (2003) Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation. Eur Radiol 13:830-835
    • (2003) Eur Radiol , vol.13 , pp. 830-835
    • Maintz, D.1    Juergens, K.U.2    Wichert, T.3    Grude, M.4    Heindel, W.5    Fischbach, R.6
  • 34
    • 17044434299 scopus 로고    scopus 로고
    • Assessment of coronary artery stents using 16-slice MDCT angiography: Evaluation of a dedicated reconstruction kernel and a noise reduction filter
    • Seifarth H, Raupach R, Schaller S, Fallenberg EM, Flohr T, Heindel W, Fischbach R, Maintz D (2005) Assessment of coronary artery stents using 16-slice MDCT angiography: Evaluation of a dedicated reconstruction kernel and a noise reduction filter. Eur Radiol 15:721-726
    • (2005) Eur Radiol , vol.15 , pp. 721-726
    • Seifarth, H.1    Raupach, R.2    Schaller, S.3    Fallenberg, E.M.4    Flohr, T.5    Heindel, W.6    Fischbach, R.7    Maintz, D.8
  • 36
    • 0037366639 scopus 로고    scopus 로고
    • Use of high concentration contrast media: Principles and rationale- vascular district
    • Fleischmann D (2003) Use of high concentration contrast media: principles and rationale- vascular district. Eur J Radiol 45(Suppl 1):S88-S93
    • (2003) Eur J Radiol , vol.45 , Issue.SUPPL. 1
    • Fleischmann, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.