-
1
-
-
0027690838
-
Dynamic gadolinium-enhanced three-dimensional abdominal MR arteriography
-
Prince M, Yucel E, Kaufman J, Harrison D, Geller S. Dynamic gadolinium-enhanced three-dimensional abdominal MR arteriography. J Magn Reson Imaging 1993;3:877-881
-
(1993)
J Magn Reson Imaging
, vol.3
, pp. 877-881
-
-
Prince, M.1
Yucel, E.2
Kaufman, J.3
Harrison, D.4
Geller, S.5
-
2
-
-
0033014248
-
Aortoiliac and lower extremity arteries: Comparison of three-dimensional dynamic contrast-enhanced subtraction MR angiography and conventional angiography
-
Sueyoshi E. Sakamoto I, Matsuoka Y, et al. Aortoiliac and lower extremity arteries: comparison of three-dimensional dynamic contrast-enhanced subtraction MR angiography and conventional angiography. Radiology 1999;210:683-686
-
(1999)
Radiology
, vol.210
, pp. 683-686
-
-
Sueyoshi, E.1
Sakamoto, I.2
Matsuoka, Y.3
-
3
-
-
0032811088
-
Iliofemoral arterial occlusive disease: Contrast-enhanced MR angiography for preinterventional evaluation and follow-up after stent placement
-
Link J, Steffens J, Brossmann J, Graessner J. Hackethal S, Heller M. Iliofemoral arterial occlusive disease: contrast-enhanced MR angiography for preinterventional evaluation and follow-up after stent placement. Radiology 1999:212:371-377
-
(1999)
Radiology
, vol.212
, pp. 371-377
-
-
Link, J.1
Steffens, J.2
Brossmann, J.3
Graessner, J.4
Hackethal, S.5
Heller, M.6
-
4
-
-
0034079877
-
Aorta and iliac arteries: Single versus multiple detector-row helical CT angiography
-
Rubin GD, Shiau MC, Leung AN, Kee ST, Logan LJ, Sofilos MC. Aorta and iliac arteries: single versus multiple detector-row helical CT angiography. Radiology 2000;215:670-676
-
(2000)
Radiology
, vol.215
, pp. 670-676
-
-
Rubin, G.D.1
Shiau, M.C.2
Leung, A.N.3
Kee, S.T.4
Logan, L.J.5
Sofilos, M.C.6
-
5
-
-
0033001948
-
Metallic artifacts of coronary and iliac arteries stents in MR angiography and contrast-enhanced CT
-
Amano Y, Ishihara M, Hayashi H, et al. Metallic artifacts of coronary and iliac arteries stents in MR angiography and contrast-enhanced CT. Clin Imaging 1999;23:85-89
-
(1999)
Clin Imaging
, vol.23
, pp. 85-89
-
-
Amano, Y.1
Ishihara, M.2
Hayashi, H.3
-
6
-
-
0034543124
-
Stent appearance at contrast-enhanced MR angiography: In vitro examination with 14 stents
-
Lenhart M, Volk M, Manke C, et al. Stent appearance at contrast-enhanced MR angiography: in vitro examination with 14 stents. Radiology 2000;217:173-178
-
(2000)
Radiology
, vol.217
, pp. 173-178
-
-
Lenhart, M.1
Volk, M.2
Manke, C.3
-
7
-
-
0035067940
-
In vitro evaluation of intravascular stent artifacts in three-dimensional MR angiography
-
Maintz D, Kugel H, Schellhammer F, Landwehr A. In vitro evaluation of intravascular stent artifacts in three-dimensional MR angiography. Invest Radiol 2001;36:218-224
-
(2001)
Invest Radiol
, vol.36
, pp. 218-224
-
-
Maintz, D.1
Kugel, H.2
Schellhammer, F.3
Landwehr, A.4
-
8
-
-
0035107929
-
MR imaging of vascular stents: Effect of susceptibility, flow, and radiofrequency eddy currents
-
Bartels L, Smits H, Bakker C, Viergever M. MR imaging of vascular stents: effect of susceptibility, flow, and radiofrequency eddy currents. J Vasc Interv Radiol 2001;12:365-371
-
(2001)
J Vasc Interv Radiol
, vol.12
, pp. 365-371
-
-
Bartels, L.1
Smits, H.2
Bakker, C.3
Viergever, M.4
-
9
-
-
0035660731
-
Multislice CT angiography of the iliac arteries in the presence of various stents: In vitro evaluation of artifacts and lumen visibility
-
Maintz D, Fischbach R, Juergens K-U, Allkemper T, Wessling J, Heindel W. Multislice CT angiography of the iliac arteries in the presence of various stents: in vitro evaluation of artifacts and lumen visibility. Invest Radiol 2001;36:699-704
-
(2001)
Invest Radiol
, vol.36
, pp. 699-704
-
-
Maintz, D.1
Fischbach, R.2
Juergens, K.-U.3
Allkemper, T.4
Wessling, J.5
Heindel, W.6
-
10
-
-
0345298274
-
Plain and covered stent-grafts: In vitro evaluation of characteristics at three-dimensional MR angiography
-
Hilfiker P, Quick H, Debatin J. Plain and covered stent-grafts: in vitro evaluation of characteristics at three-dimensional MR angiography. Radiology 1999:211:693-697
-
(1999)
Radiology
, vol.211
, pp. 693-697
-
-
Hilfiker, P.1
Quick, H.2
Debatin, J.3
-
11
-
-
0001587616
-
A phantom study to validate image acquisition and reconstruction parameters in imaging of coronary stents using multislice spiral CT (MSCT) in vitro
-
Schulte C, Giesler T, Baum U, et al. A phantom study to validate image acquisition and reconstruction parameters in imaging of coronary stents using multislice spiral CT (MSCT) in vitro. (abstr) Eur Radiol 2001:11:179
-
(2001)
Eur Radiol
, vol.11
, pp. 179
-
-
Schulte, C.1
Giesler, T.2
Baum, U.3
|