메뉴 건너뛰기




Volumn 15, Issue 6, 2006, Pages 1927-1938

Design and experimental evaluation of piecewise output feedback control for structural vibration suppression

Author keywords

[No Author keywords available]

Indexed keywords

ACTUATORS; COMPUTER SIMULATION; MATHEMATICAL MODELS; PIEZOELECTRIC DEVICES; RESONANCE; SENSORS; VIBRATIONS (MECHANICAL);

EID: 33846087802     PISSN: 09641726     EISSN: 1361665X     Source Type: Journal    
DOI: 10.1088/0964-1726/15/6/049     Document Type: Article
Times cited : (19)

References (21)
  • 1
    • 0036850488 scopus 로고    scopus 로고
    • Review of state of art of smart structures and integrated systems
    • Chopra I 2002 Review of state of art of smart structures and integrated systems AIAA J. 40 2145-87
    • (2002) AIAA J. , vol.40 , Issue.11 , pp. 2145-2187
    • Chopra, I.1
  • 2
    • 0000881827 scopus 로고    scopus 로고
    • Distributed piezoelectric segment method for vibration control of smart beams
    • Sun D, Wang D and Xu Z L 1996 Distributed piezoelectric segment method for vibration control of smart beams AIAA J. 35 583-4
    • (1996) AIAA J. , vol.35 , pp. 583-584
    • Sun, D.1    Wang, D.2    Xu, Z.L.3
  • 3
    • 0032687602 scopus 로고    scopus 로고
    • Finite element simulation of smart structures using an optimal output feedback controller for vibration and noise control
    • Lim Y-H, Gopinathan S V, Varadan V V and Varadan VK 1999 Finite element simulation of smart structures using an optimal output feedback controller for vibration and noise control Smart Mater. Struct. 8 324-37
    • (1999) Smart Mater. Struct. , vol.8 , Issue.3 , pp. 324-337
    • Lim, Y.-H.1    Gopinathan, S.V.2    Varadan, V.V.3    Varadan, V.K.4
  • 4
    • 0026924880 scopus 로고
    • Optimal vibration control by the use of piezoceramic sensors and actuators
    • Hanagud S, Obal M W and Callise A J 1992 Optimal vibration control by the use of piezoceramic sensors and actuators J. Guid. Control Dyn. 15 1199-206
    • (1992) J. Guid. Control Dyn. , vol.15 , Issue.5 , pp. 1199-1206
    • Hanagud, S.1    Obal, M.W.2    Callise, A.J.3
  • 5
    • 0037904240 scopus 로고    scopus 로고
    • Finite element modeling of piezolaminated smart structures for active vibration control with distributed sensors and actuators
    • Narayanan S and Balamurugan V 2003 Finite element modeling of piezolaminated smart structures for active vibration control with distributed sensors and actuators J. Sound Vib. 262 529-62
    • (2003) J. Sound Vib. , vol.262 , Issue.3 , pp. 529-562
    • Narayanan, S.1    Balamurugan, V.2
  • 6
    • 0027592361 scopus 로고
    • Finite element modeling of piezoelectric sensors and actuators
    • Hwang W and Park H C 1993 Finite element modeling of piezoelectric sensors and actuators AIAA J. 31 930-7
    • (1993) AIAA J. , vol.31 , pp. 930-937
    • Hwang, W.1    Park, H.C.2
  • 7
    • 0032653332 scopus 로고    scopus 로고
    • Closed loop finite element modeling of active structural damping in the time domain
    • Lim Y-H, Varadan V V and Varadan V K 1999 Closed loop finite element modeling of active structural damping in the time domain Smart Mater. Struct. 8 390-400
    • (1999) Smart Mater. Struct. , vol.8 , Issue.3 , pp. 390-400
    • Lim, Y.-H.1    Varadan, V.V.2    Varadan, V.K.3
  • 8
    • 0036029458 scopus 로고    scopus 로고
    • Controller design for engineering smart structures based on finite element models
    • Gabbert U, Koppe H and Trajkov T N 2002 Controller design for engineering smart structures based on finite element models Smart Structures and Materials Proc. SPIE 4693 430-9
    • (2002) Proc. SPIE , vol.4693 , pp. 430-439
    • Gabbert, U.1    Koppe, H.2    Trajkov, T.N.3
  • 9
    • 3042606553 scopus 로고    scopus 로고
    • Experimental evaluation of augmented UD identification based vibration control of smart structures
    • He C and Jha R 2003 Experimental evaluation of augmented UD identification based vibration control of smart structures J. Sound Vib. 274 1065-78
    • (2003) J. Sound Vib. , vol.274 , Issue.3-5 , pp. 1065-1078
    • He, C.1    Jha, R.2
  • 10
    • 0032141447 scopus 로고    scopus 로고
    • Structural vibration control using PZT patches and non-linear phenomena
    • Pai P F, Wen B, Naser A S and Schulz M J 1998 Structural vibration control using PZT patches and non-linear phenomena J. Sound Vib. 215 273-96
    • (1998) J. Sound Vib. , vol.215 , Issue.2 , pp. 273-296
    • Pai, P.F.1    Wen, B.2    Naser, A.S.3    Schulz, M.J.4
  • 11
    • 0030400498 scopus 로고    scopus 로고
    • Structural vibration suppression by concurrent piezoelectric sensor and actuator
    • Yang S M and Jeng C A 1996 Structural vibration suppression by concurrent piezoelectric sensor and actuator Smart Mater. Struct. 5 806-13
    • (1996) Smart Mater. Struct. , vol.5 , Issue.6 , pp. 806-813
    • Yang, S.M.1    Jeng, C.A.2
  • 14
    • 0142124229 scopus 로고    scopus 로고
    • Active control of a flexible smart beam using a system identification technique based on ARMAX
    • Bu X, Ye L, Su Z and Wang C 2003 Active control of a flexible smart beam using a system identification technique based on ARMAX Smart Mater. Struct. 12 845-50
    • (2003) Smart Mater. Struct. , vol.12 , Issue.5 , pp. 845-850
    • Bu, X.1    Ye, L.2    Su, Z.3    Wang, C.4
  • 15
    • 0001027754 scopus 로고
    • Vibration suppression with optimal sensor/actuator location and feedback gain
    • Yang S M and Lee Y J 1993 Vibration suppression with optimal sensor/actuator location and feedback gain Smart Mater. Struct. 2 232-9
    • (1993) Smart Mater. Struct. , vol.2 , Issue.4 , pp. 232-239
    • Yang, S.M.1    Lee, Y.J.2
  • 16
    • 0028420020 scopus 로고
    • Collocated sensor/actuator positioning and feed back design in the control of flexible structure system
    • Lee A-C and Chen S-T 1994 Collocated sensor/actuator positioning and feed back design in the control of flexible structure system Trans. ASME J. Vib. Acoust. 116 146-54
    • (1994) J. Vib. Acoust. , vol.116 , pp. 146-154
    • Lee, A.-C.1    Chen, S.-T.2
  • 18
    • 0001589886 scopus 로고
    • Simultaneous stabilization based on output measurements
    • Werner H and Furuta K 1995 Simultaneous stabilization based on output measurements Kybernetika 31 395-411
    • (1995) Kybernetika , vol.31 , Issue.4 , pp. 395-411
    • Werner, H.1    Furuta, K.2
  • 19
    • 0029405686 scopus 로고
    • Simultaneous stabilization by piecewise constant periodic output feedback
    • Werner H and Furuta K 1995 Simultaneous stabilization by piecewise constant periodic output feedback Control Theory Adv. Technol. 10 1763-75
    • (1995) Control Theory Adv. Technol. , vol.10 , Issue.4 , pp. 1763-1775
    • Werner, H.1    Furuta, K.2
  • 20
    • 0032299060 scopus 로고    scopus 로고
    • Multimodel robust control by fast output sampling-an LMI approach
    • Werner H 1998 Multimodel robust control by fast output sampling-an LMI approach Automatica 34 1625-30
    • (1998) Automatica , vol.34 , Issue.12 , pp. 1625-1630
    • Werner, H.1
  • 21
    • 0018319049 scopus 로고
    • Pole placement by piecewise constant output feedback
    • Chammas A B and Leondes C T 1979 Pole placement by piecewise constant output feedback Int. J. Control 29 31-8
    • (1979) Int. J. Control , vol.29 , Issue.1 , pp. 31-38
    • Chammas, A.B.1    Leondes, C.T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.