Characterisation of medical aerosols: Physical and clinical requirements for new inhalers
-
M. Dolovich. Characterisation of medical aerosols: physical and clinical requirements for new inhalers. Aerosol. Sci. Tech. 22:392-399 (1995).
-
(1995)
Aerosol. Sci. Tech
, vol.22
, pp. 392-399
-
-
Dolovich, M.1
-
2
-
-
0030581128
-
Inhalation characteristics and their effect on in vitro drug delivery from dry powder inhalers. Part 2: Effect of peak flow rate (PIFR) and inspiration time on the in vitro drug release from 3 types of commercial dry powder inhalers
-
A. H. de Boer, D. Gjaltema, and P. Hagedoorn. Inhalation characteristics and their effect on in vitro drug delivery from dry powder inhalers. Part 2: effect of peak flow rate (PIFR) and inspiration time on the in vitro drug release from 3 types of commercial dry powder inhalers. Int. J. Pharm. 138:45-56 (1996).
-
(1996)
Int. J. Pharm
, vol.138
, pp. 45-56
-
-
de Boer, A.H.1
Gjaltema, D.2
Hagedoorn, P.3
-
3
-
-
0029973878
-
Effect of inhalation flow rate on the dosing characteristics of dry powder inhaler (DPI) and metered dose inhaler (MDI) products
-
D. L. Ross and R. K. Schultz. Effect of inhalation flow rate on the dosing characteristics of dry powder inhaler (DPI) and metered dose inhaler (MDI) products. J. Aerosol Med. 9:215-226 (1996).
-
(1996)
J. Aerosol Med
, vol.9
, pp. 215-226
-
-
Ross, D.L.1
Schultz, R.K.2
-
4
-
-
0027940019
-
The characterisation of inhalation devices by an inhalation simulator: The Electronic Lung
-
A. Brindley, B. S. Sumby, and I. J. Smith. The characterisation of inhalation devices by an inhalation simulator: the Electronic Lung. J. Aerosol Med. 7:197-200 (1994).
-
(1994)
J. Aerosol Med
, vol.7
, pp. 197-200
-
-
Brindley, A.1
Sumby, B.S.2
Smith, I.J.3
-
5
-
-
0008255387
-
Patient inhalation profiles and dose emission characteristics from dry powder inhalers
-
B. R. Byron, R. N. Dalby, and S. J. Farr eds, Phoenix, Arizona
-
P. K. P. Burnell, L. Petchey, D. Prime, and B. S. Sumby. Patient inhalation profiles and dose emission characteristics from dry powder inhalers. In B. R. Byron, R. N. Dalby, and S. J. Farr (eds.), Respiratory Drug Delivery V, Phoenix, Arizona, 1996.
-
(1996)
Respiratory Drug Delivery V
-
-
Burnell, P.K.P.1
Petchey, L.2
Prime, D.3
Sumby, B.S.4
-
6
-
-
18044404862
-
Effect of rise in simulated inspiratory flow rate and carrier particle size on powder emptying from dry powder inhalers
-
V. S. Chavan and R. N. Dalby. Effect of rise in simulated inspiratory flow rate and carrier particle size on powder emptying from dry powder inhalers. AAPS PharmSCi 2(10):1-7 (2000).
-
(2000)
AAPS PharmSCi
, vol.2
, Issue.10
, pp. 1-7
-
-
Chavan, V.S.1
Dalby, R.N.2
-
7
-
-
85046914814
-
Novel system to investigate the effects of inhaled volume and rates of rise in simulated inspiratory air flow on fine particle output from a dry powder inhaler
-
V. S. Chavan and R. N. Dalby. Novel system to investigate the effects of inhaled volume and rates of rise in simulated inspiratory air flow on fine particle output from a dry powder inhaler. AAPS PharmSci 4(6):1-6 (2001).
-
(2001)
AAPS PharmSci
, vol.4
, Issue.6
, pp. 1-6
-
-
Chavan, V.S.1
Dalby, R.N.2
-
8
-
-
0028031785
-
Effect of different modes of inhalation on drug delivery from a dry powder inhaler
-
S. P. Newman, A. H. Hollingworth, and A. R. Clarke. Effect of different modes of inhalation on drug delivery from a dry powder inhaler. Int. J. Pharm. 102:127-132 (1994).
-
(1994)
Int. J. Pharm
, vol.102
, pp. 127-132
-
-
Newman, S.P.1
Hollingworth, A.H.2
Clarke, A.R.3
-
9
-
-
0031054488
-
The impact of inspiratory effort on inspiratory flow through Turbuhaleri in asthmatic patients
-
G. Persson, B. Olsson, and S. Soliman. The impact of inspiratory effort on inspiratory flow through Turbuhaleri in asthmatic patients. Eur. Respir. J. 10:681-684 (1997).
-
(1997)
Eur. Respir. J
, vol.10
, pp. 681-684
-
-
Persson, G.1
Olsson, B.2
Soliman, S.3
-
10
-
-
0032171467
-
Design, validation and initial testing of the electronic lungi device
-
B. K. P. Burnell, A. Malton, K. Reavill, and M. H. E. Ball. Design, validation and initial testing of the electronic lungi device. J. Aerosol Sci. 29:1011-1025 (1998).
-
(1998)
J. Aerosol Sci
, vol.29
, pp. 1011-1025
-
-
Burnell, B.K.P.1
Malton, A.2
Reavill, K.3
Ball, M.H.E.4
-
11
-
-
0005253391
-
The in-vitro characterization of inhalation devices using the electronic lungi
-
B. R. Byron, R. N. Dalby, and S. J. Farr eds, Illinois
-
A. Brindley, K. J. Reavill, B. S. Sumby, and I. J. Smith. The in-vitro characterization of inhalation devices using the electronic lungi. In B. R. Byron, R. N. Dalby, and S. J. Farr (eds.), Respiratory Drug Delivery IV, Interpharm, Buffalo Grove, Illinois, 1994.
-
(1994)
Respiratory Drug Delivery IV, Interpharm, Buffalo Grove
-
-
Brindley, A.1
Reavill, K.J.2
Sumby, B.S.3
Smith, I.J.4
-
12
-
-
0030795605
-
Inhalation characteristics and their effects on in vitro drug delivery from dry powder inhalers. Part 3: The effect of flow increase rate (FIR) on the in vitro drug release from the Pulmicort 200 Turbuhaler
-
A. H. de Boer, G. K. Bolhuis, D. Gjaltema, and P. Hagedoorn. Inhalation characteristics and their effects on in vitro drug delivery from dry powder inhalers. Part 3: the effect of flow increase rate (FIR) on the in vitro drug release from the Pulmicort 200 Turbuhaler. Int. J. Pharm. 153:67-77 (1997).
-
(1997)
Int. J. Pharm
, vol.153
, pp. 67-77
-
-
de Boer, A.H.1
Bolhuis, G.K.2
Gjaltema, D.3
Hagedoorn, P.4
-
13
-
-
0034605980
-
Inertial sizing of aerosol inhaled from two dry powder inhalers with realistic breath patterns versus constant flow rates
-
W. H. Finlay and M. G. Gehmlich. Inertial sizing of aerosol inhaled from two dry powder inhalers with realistic breath patterns versus constant flow rates. Int. J. Pharm. 210:83-95 (2000).
-
(2000)
Int. J. Pharm
, vol.210
, pp. 83-95
-
-
Finlay, W.H.1
Gehmlich, M.G.2
-
14
-
-
33750598383
-
Correlation between inertial impaction and laser diffraction sizing data for aerosolized carrier-based dry powder formulations
-
X. M. Zeng, H. B. MacRitchie, C. Marriott, and G. P. Martin. Correlation between inertial impaction and laser diffraction sizing data for aerosolized carrier-based dry powder formulations. Pharm. Res. 23(9):2200-2209 (2006).
-
(2006)
Pharm. Res
, vol.23
, Issue.9
, pp. 2200-2209
-
-
Zeng, X.M.1
MacRitchie, H.B.2
Marriott, C.3
Martin, G.P.4
-
15
-
-
33750595241
-
Characterisation of a carrier-free dry powder aerosol formulation using inertial impaction and laser diffraction
-
G. P. Martin, H. B. MacRitchie, C. Marriott, and X. M. Zeng. Characterisation of a carrier-free dry powder aerosol formulation using inertial impaction and laser diffraction. Pharm. Res. 23(9):2210-2219 (2006).
-
(2006)
Pharm. Res
, vol.23
, Issue.9
, pp. 2210-2219
-
-
Martin, G.P.1
MacRitchie, H.B.2
Marriott, C.3
Zeng, X.M.4
-
16
-
-
33846098585
-
The Electronic Lungi™ Bridging the gap between in vitro and in vivo testing
-
London
-
D. S. MacArthur and S. G. Fleck. The Electronic Lungi™ Bridging the gap between in vitro and in vivo testing. In Proc. drug delivery to the lungs VI, London, 1995.
-
(1995)
Proc. drug delivery to the lungs VI
-
-
MacArthur, D.S.1
Fleck, S.G.2
-
17
-
-
33846113178
-
Use of inhalation profiles from patients with severe obstructive lung disease using the Diskusi inhaler and Turbuhaler™ inhaler to evaluate device performance ex vivo
-
Berlin
-
T. Small, S. Doig, G. J. Gibson, B. Johal, P. K. P. Burnell, and R. Jenkins. Use of inhalation profiles from patients with severe obstructive lung disease using the Diskusi inhaler and Turbuhaler™ inhaler to evaluate device performance ex vivo. In Proc. European Respiratory Society Annual Congress, Berlin, 1997.
-
(1997)
Proc. European Respiratory Society Annual Congress
-
-
Small, T.1
Doig, S.2
Gibson, G.J.3
Johal, B.4
Burnell, P.K.P.5
Jenkins, R.6
|