메뉴 건너뛰기




Volumn 16, Issue 1, 2007, Pages 1-3

The changing spectrum of porcine bioprosthetic valve failure

Author keywords

[No Author keywords available]

Indexed keywords

AORTA VALVE PROSTHESIS; BIOCOMPATIBILITY; BIOPROSTHESIS; EDITORIAL; HEART VALVE PROSTHESIS; HEMOLYSIS; NOISE; NONHUMAN; PRIORITY JOURNAL; PROSTHESIS FAILURE; SAINT JUDE HEART VALVE PROSTHESIS; SWINE; THROMBOEMBOLISM;

EID: 33845983315     PISSN: 10548807     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.carpath.2006.09.008     Document Type: Editorial
Times cited : (2)

References (25)
  • 2
    • 0009466526 scopus 로고
    • Carpentier-Edwards standard porcine bioprostheses: clinical performances to seventeen years
    • Jamieson W., Munro A., Miyagishima R., Allen P., Burr L., and Tyers G. Carpentier-Edwards standard porcine bioprostheses: clinical performances to seventeen years. Ann Thorac Surg 48 (1989) S81-S82
    • (1989) Ann Thorac Surg , vol.48
    • Jamieson, W.1    Munro, A.2    Miyagishima, R.3    Allen, P.4    Burr, L.5    Tyers, G.6
  • 6
    • 0035022101 scopus 로고    scopus 로고
    • Carpentier-Edwards supraannular porcine bioprosthesis: second-generation prosthesis in aortic valve replacement
    • Jamieson W., Janusz M., Burr L., Ling H., Miyagishima R., and Germann E. Carpentier-Edwards supraannular porcine bioprosthesis: second-generation prosthesis in aortic valve replacement. Ann Thorac Surg 71 (2001) S224-S227
    • (2001) Ann Thorac Surg , vol.71
    • Jamieson, W.1    Janusz, M.2    Burr, L.3    Ling, H.4    Miyagishima, R.5    Germann, E.6
  • 8
    • 33845992227 scopus 로고    scopus 로고
    • A 10-year comparison of explanted Hancock-II and Carpentier-Edwards supraannular bioprostheses
    • Butany J., Leong S., Cunningham K., D'Cruz G., Carmichael K., and Yau T. A 10-year comparison of explanted Hancock-II and Carpentier-Edwards supraannular bioprostheses. Cardiovasc Pathol 16 (2006) 4-13
    • (2006) Cardiovasc Pathol , vol.16 , pp. 4-13
    • Butany, J.1    Leong, S.2    Cunningham, K.3    D'Cruz, G.4    Carmichael, K.5    Yau, T.6
  • 12
    • 33845996423 scopus 로고
    • International Standardization Organization, Geneva, Switzerland
    • ISO standard 5840 (1989), International Standardization Organization, Geneva, Switzerland
    • (1989) ISO standard 5840
  • 13
    • 33846026983 scopus 로고
    • European Committee for Standardization, Brussels, Belgium
    • CEN prop. standard EN 12006-1 (1995), European Committee for Standardization, Brussels, Belgium
    • (1995) CEN prop. standard EN 12006-1
  • 15
    • 0021239471 scopus 로고
    • Fatigue-induced failure of the Ionescu-Shiley pericardial xenograft in the mitral position. In vivo and in vitro correlation and a proposed classification
    • Gabbay S., Bortolotti U., Wasserman F., Factor S., Strom J., and Frater R. Fatigue-induced failure of the Ionescu-Shiley pericardial xenograft in the mitral position. In vivo and in vitro correlation and a proposed classification. J Thorac Cardiovasc Surg 87 (1984) 836-844
    • (1984) J Thorac Cardiovasc Surg , vol.87 , pp. 836-844
    • Gabbay, S.1    Bortolotti, U.2    Wasserman, F.3    Factor, S.4    Strom, J.5    Frater, R.6
  • 17
    • 33751163273 scopus 로고    scopus 로고
    • Letter to the Editor: Durability of valve bioprosthesis and the need of careful examination of explants
    • [in press]
    • Thiene G. Letter to the Editor: Durability of valve bioprosthesis and the need of careful examination of explants. Ann Thorac Surg (2006) [in press]
    • (2006) Ann Thorac Surg
    • Thiene, G.1
  • 19
    • 0024190797 scopus 로고
    • Lessons learned about the determinants of the results of valve surgery
    • Rahimtoola S. Lessons learned about the determinants of the results of valve surgery. Circulation 78 (1988) 1503-1507
    • (1988) Circulation , vol.78 , pp. 1503-1507
    • Rahimtoola, S.1
  • 20
    • 0037454165 scopus 로고    scopus 로고
    • Choice of prosthetic heart valve for adult patients
    • Rahimtoola S. Choice of prosthetic heart valve for adult patients. J Am Coll Cardiol 41 (2003) 893-904
    • (2003) J Am Coll Cardiol , vol.41 , pp. 893-904
    • Rahimtoola, S.1
  • 21
    • 0028857246 scopus 로고
    • Comparative assessment of bioprosthesis durability in the aortic position
    • Grunkemeier G., and Bodnar E. Comparative assessment of bioprosthesis durability in the aortic position. J Heart Valve Dis 4 (1995) 49-55
    • (1995) J Heart Valve Dis , vol.4 , pp. 49-55
    • Grunkemeier, G.1    Bodnar, E.2
  • 22
    • 0029155601 scopus 로고
    • The Carpentier-Edwards pericardial bioprosthesis: clinical experience with 600 patients
    • Pelletier L., Carrier M., Leclerc Y., and Dyrda I. The Carpentier-Edwards pericardial bioprosthesis: clinical experience with 600 patients. Ann Thorac Surg 60 (1995) S297-S302
    • (1995) Ann Thorac Surg , vol.60
    • Pelletier, L.1    Carrier, M.2    Leclerc, Y.3    Dyrda, I.4
  • 23
    • 0036897853 scopus 로고    scopus 로고
    • Ten-year echocardiographic and clinical follow-up of aortic Carpentier-Edwards pericardial and supraannular prosthesis: a case-match study
    • Le Tourneau T., Vincentelli A., Fayad G., Savoye C., Fabre O., Prat A., and Warembourg H. Ten-year echocardiographic and clinical follow-up of aortic Carpentier-Edwards pericardial and supraannular prosthesis: a case-match study. Ann Thorac Surg 74 (2002) 2010-2015
    • (2002) Ann Thorac Surg , vol.74 , pp. 2010-2015
    • Le Tourneau, T.1    Vincentelli, A.2    Fayad, G.3    Savoye, C.4    Fabre, O.5    Prat, A.6    Warembourg, H.7
  • 24
    • 0031784355 scopus 로고    scopus 로고
    • Retrieval analysis of mechanical heart valves: impact on design and clinical practice
    • Cromheecke M., Overkamp P., de Mol B., Van Gaalen G., and Becker A. Retrieval analysis of mechanical heart valves: impact on design and clinical practice. Artif Organs 22 (1998) 794-799
    • (1998) Artif Organs , vol.22 , pp. 794-799
    • Cromheecke, M.1    Overkamp, P.2    de Mol, B.3    Van Gaalen, G.4    Becker, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.