1
-
-
0035176116
-
Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twenty-one-year results
-
Urban J.A., Garvin K.L., Boese C.K., et al. Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twenty-one-year results. J Bone Joint Surg Am 83-A (2001) 1688
-
(2001)
J Bone Joint Surg Am
, vol.83 -A
, pp. 1688
-
-
Urban, J.A.1
Garvin, K.L.2
Boese, C.K.3
-
2
-
-
0026974544
-
Comparative wear studies of 28 mm ceramic and metal total hip implants over a 2-7 year period
-
Oonishi H., Takayaka Y., Clarke I.C., et al. Comparative wear studies of 28 mm ceramic and metal total hip implants over a 2-7 year period. J Long Term Eff Med Implants 2 (1992) 37
-
(1992)
J Long Term Eff Med Implants
, vol.2
, pp. 37
-
-
Oonishi, H.1
Takayaka, Y.2
Clarke, I.C.3
-
3
-
-
0036056821
-
Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study
-
Hamadouche M., Boutin P., Daussange J., et al. Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg Am 84-A (2002) 69
-
(2002)
J Bone Joint Surg Am
, vol.84 -A
, pp. 69
-
-
Hamadouche, M.1
Boutin, P.2
Daussange, J.3
-
4
-
-
18844470639
-
-
Oonishi H, Clarke IC, Williams PA, et al. Characterization of steady-state wear in all-alumina THR to 20 mc. Key Engineering Materials. 2002;218-220:587.
-
-
-
-
5
-
-
0030634935
-
The wear of ultrahigh molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement
-
Lancaster J.G., Dowson D., Isaac G.H., et al. The wear of ultrahigh molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement. Proc Inst Mech Eng [H] 211 (1997) 17
-
(1997)
Proc Inst Mech Eng [H]
, vol.211
, pp. 17
-
-
Lancaster, J.G.1
Dowson, D.2
Isaac, G.H.3
-
6
-
-
0942268880
-
Damage of an alumina-on-alumina bearing surface from a difficult reduction of a total hip arthroplasty. A report of three cases
-
Yoo J.J., Kim H.J., and Kim Y.M. Damage of an alumina-on-alumina bearing surface from a difficult reduction of a total hip arthroplasty. A report of three cases. J Bone Joint Surg Am 86-A (2004) 376
-
(2004)
J Bone Joint Surg Am
, vol.86 -A
, pp. 376
-
-
Yoo, J.J.1
Kim, H.J.2
Kim, Y.M.3
-
7
-
-
0031718595
-
Drain entrapment and titanium to ceramic head deposition: two unique complications following closed reduction of a dislocated total hip arthroplasty
-
Luchetti W.T., Copley L.A., Vresilovic E.J., et al. Drain entrapment and titanium to ceramic head deposition: two unique complications following closed reduction of a dislocated total hip arthroplasty. J Arthroplasty 13 (1998) 713
-
(1998)
J Arthroplasty
, vol.13
, pp. 713
-
-
Luchetti, W.T.1
Copley, L.A.2
Vresilovic, E.J.3
-
9
-
-
0033781822
-
Ceramic femoral head retrieval data
-
Willmann G. Ceramic femoral head retrieval data. Clin Orthop Relat Res (2000) 22
-
(2000)
Clin Orthop Relat Res
, pp. 22
-
-
Willmann, G.1
-
10
-
-
14644414879
-
Surface roughness of ceramic femoral heads after in vivo transfer of metal: correlation to polyethylene wear
-
Kim Y.H., Ritchie A., and Hardaker C. Surface roughness of ceramic femoral heads after in vivo transfer of metal: correlation to polyethylene wear. J Bone Joint Surg Am 87 (2005) 577
-
(2005)
J Bone Joint Surg Am
, vol.87
, pp. 577
-
-
Kim, Y.H.1
Ritchie, A.2
Hardaker, C.3
-
11
-
-
2642584746
-
Edge loading in third generation alumina ceramic-on-ceramic bearings: stripe wear
-
Walter W.L., Insley G.M., Walter W.K., et al. Edge loading in third generation alumina ceramic-on-ceramic bearings: stripe wear. J Arthroplasty 19 (2004) 402
-
(2004)
J Arthroplasty
, vol.19
, pp. 402
-
-
Walter, W.L.1
Insley, G.M.2
Walter, W.K.3
-
12
-
-
0031943677
-
Catastrophic failure of the acetabular component in a ceramic-polyethylene bearing total hip arthroplasty
-
Simon J.A., Dayan A.J., Ergas E., et al. Catastrophic failure of the acetabular component in a ceramic-polyethylene bearing total hip arthroplasty. J Arthroplasty 13 (1998) 108
-
(1998)
J Arthroplasty
, vol.13
, pp. 108
-
-
Simon, J.A.1
Dayan, A.J.2
Ergas, E.3
-
13
-
-
0028013728
-
Long-term results of uncemented alumina acetabular implants
-
Boehler M., Knahr K., Plenk Jr. H., et al. Long-term results of uncemented alumina acetabular implants. J Bone Joint Surg Br 76 (1994) 53
-
(1994)
J Bone Joint Surg Br
, vol.76
, pp. 53
-
-
Boehler, M.1
Knahr, K.2
Plenk Jr., H.3
-
14
-
-
0034757648
-
Poor outcome of 44 cemented total hip arthroplasties with alumina ceramic heads: clinical evaluation and retrieval analysis after 10-16 years
-
Hasegawa M., Ohashi T., and Tani T. Poor outcome of 44 cemented total hip arthroplasties with alumina ceramic heads: clinical evaluation and retrieval analysis after 10-16 years. Acta Orthop Scand 72 (2001) 449
-
(2001)
Acta Orthop Scand
, vol.72
, pp. 449
-
-
Hasegawa, M.1
Ohashi, T.2
Tani, T.3
-
15
-
-
0025350439
-
Unsatisfactory results with a ceramic total hip prosthesis
-
[see comment]
-
Mahoney O.M., and Dimon III J.H. Unsatisfactory results with a ceramic total hip prosthesis. [see comment]. J Bone Joint Surg Am 72 (1990) 663
-
(1990)
J Bone Joint Surg Am
, vol.72
, pp. 663
-
-
Mahoney, O.M.1
Dimon III, J.H.2
-
17
-
-
0030911376
-
Massive osteolysis after ceramic on ceramic total hip arthroplasty. A case report
-
[see comment]
-
Wirganowicz P.Z., and Thomas B.J. Massive osteolysis after ceramic on ceramic total hip arthroplasty. A case report. [see comment]. Clin Orthop Relat Res (1997) 100
-
(1997)
Clin Orthop Relat Res
, pp. 100
-
-
Wirganowicz, P.Z.1
Thomas, B.J.2
-
18
-
-
0031758471
-
Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces
-
[see comment]
-
Yoon T.R., Rowe S.M., Jung S.T., et al. Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces. [see comment]. J Bone Joint Surg Am 80 (1998) 1459
-
(1998)
J Bone Joint Surg Am
, vol.80
, pp. 1459
-
-
Yoon, T.R.1
Rowe, S.M.2
Jung, S.T.3
-
19
-
-
0032605637
-
A review of metallic, ceramic and surface-treated metals used for bearing surfaces in human joint replacements
-
Dearnley P.A. A review of metallic, ceramic and surface-treated metals used for bearing surfaces in human joint replacements. Proc Inst Mech Eng [H] 213 (1999) 107
-
(1999)
Proc Inst Mech Eng [H]
, vol.213
, pp. 107
-
-
Dearnley, P.A.1
-
20
-
-
0027086182
-
Debris-mediated osteolysis-a cascade phenomenon involving motion, wear, particulates, macrophage induction and bone lysis
-
St. John K.R. (Ed), ASTM, Philadelphia (Pa)
-
Clarke I.C., Campbell P.A., and Mishra A.K. Debris-mediated osteolysis-a cascade phenomenon involving motion, wear, particulates, macrophage induction and bone lysis. In: St. John K.R. (Ed). Particulate debris from medical implants (1992), ASTM, Philadelphia (Pa) 7
-
(1992)
Particulate debris from medical implants
, pp. 7
-
-
Clarke, I.C.1
Campbell, P.A.2
Mishra, A.K.3
-
21
-
-
0025642529
-
Cementless total joint arthroplasty prostheses with titanium-alloy articular surfaces. A human retrieval analysis
-
Nasser S., Campbell P.A., Kilgus D., et al. Cementless total joint arthroplasty prostheses with titanium-alloy articular surfaces. A human retrieval analysis. Clin Orthop (1990) 171
-
(1990)
Clin Orthop
, pp. 171
-
-
Nasser, S.1
Campbell, P.A.2
Kilgus, D.3
-
22
-
-
0033814067
-
Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns
-
[see comment]
-
Nevelos J., Ingham E., Doyle C., et al. Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns. [see comment]. J Arthroplasty 15 (2000) 793
-
(2000)
J Arthroplasty
, vol.15
, pp. 793
-
-
Nevelos, J.1
Ingham, E.2
Doyle, C.3
-
23
-
-
1642476731
-
Mechanical strength of used ceramic femoral heads
-
Thomsen M., and Breusch S.J. Mechanical strength of used ceramic femoral heads. Hip Int 13 (2003) 107
-
(2003)
Hip Int
, vol.13
, pp. 107
-
-
Thomsen, M.1
Breusch, S.J.2
-
24
-
-
0028249007
-
Abrasive wear of ceramic, metal, and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris
-
Davidson J.A., Poggie R.A., and Mishra A.K. Abrasive wear of ceramic, metal, and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris. Biomed Mater Eng 4 (1994) 213
-
(1994)
Biomed Mater Eng
, vol.4
, pp. 213
-
-
Davidson, J.A.1
Poggie, R.A.2
Mishra, A.K.3
-
25
-
-
0007568051
-
Zirconia/zirconium: a new abrasion-resistant material for othopaedic applications
-
Mishra A.K., and Davidson J.A. Zirconia/zirconium: a new abrasion-resistant material for othopaedic applications. J Mater Technol 8 (1993) 16
-
(1993)
J Mater Technol
, vol.8
, pp. 16
-
-
Mishra, A.K.1
Davidson, J.A.2
-
26
-
-
0031037345
-
Wear of retrieved cemented polyethylene acetabula with alumina femoral heads
-
Bragdon C.R., Jasty M., Kawate K., et al. Wear of retrieved cemented polyethylene acetabula with alumina femoral heads. J Arthroplasty 12 (1997) 119
-
(1997)
J Arthroplasty
, vol.12
, pp. 119
-
-
Bragdon, C.R.1
Jasty, M.2
Kawate, K.3
-
27
-
-
2642574941
-
Wear of a highly cross-linked polyethylene liner associated with metallic deposition on a ceramic femoral head
-
DellaValle A.G., Doty S., Gradl G., et al. Wear of a highly cross-linked polyethylene liner associated with metallic deposition on a ceramic femoral head. J Arthroplasty 19 (2004) 532
-
(2004)
J Arthroplasty
, vol.19
, pp. 532
-
-
DellaValle, A.G.1
Doty, S.2
Gradl, G.3
-
28
-
-
0028058239
-
Surface damage to cobalt-chrome femoral head prostheses
-
[see comment]
-
Jasty M., Bragdon C.R., Lee K., et al. Surface damage to cobalt-chrome femoral head prostheses. [see comment]. J Bone Joint Surg Br 76 (1994) 73
-
(1994)
J Bone Joint Surg Br
, vol.76
, pp. 73
-
-
Jasty, M.1
Bragdon, C.R.2
Lee, K.3
|