메뉴 건너뛰기




Volumn 38, Issue 12, 2006, Pages 1261-1267

Development and use of a quality scale for assessing studies that analyze the diagnostic capacity of capsule endoscopy

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CAPSULE ENDOSCOPY; CLINICAL TRIAL; CROHN DISEASE; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; EVIDENCE BASED MEDICINE; GASTROINTESTINAL DISEASE; GASTROINTESTINAL HEMORRHAGE; HUMAN; INFORMATION PROCESSING; MEDICAL RESEARCH; METHODOLOGY; PRIORITY JOURNAL; PUBLICATION; QUALITY CONTROL; RATING SCALE; REPRODUCIBILITY; SAFETY; SYSTEMATIC REVIEW; VALIDATION PROCESS;

EID: 33845711835     PISSN: 0013726X     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2006-944958     Document Type: Article
Times cited : (3)

References (36)
  • 1
    • 33845687461 scopus 로고    scopus 로고
    • Diagnostic effectiveness, security and clinical usefulness of capsule endoscopy in the diagnosis of small bowel disorders. Santiago de Compostela: Servicio Galego de Saúde
    • Varela Lema L, Ruano Raviña A. Diagnostic effectiveness, security and clinical usefulness of capsule endoscopy in the diagnosis of small bowel disorders. Santiago de Compostela: Servicio Galego de Saúde. Axencia de Avaliación de Tecnoloxías Sanitarias de Galicia, AVALIA-T 2005: 1-112
    • (2005) Axencia De Avaliación De Tecnoloxías Sanitarias De Galicia, AVALIA-T , pp. 1-112
    • Varela Lema, L.1    Ruano Raviña, A.2
  • 2
    • 3142687753 scopus 로고    scopus 로고
    • Effectiveness of endoscopic capsule for the detection of small-bowel bleeding of unknown origin and for the diagnosis of Crohn's disease
    • Ruano-Ravina A, Rey-Liste T. Effectiveness of endoscopic capsule for the detection of small-bowel bleeding of unknown origin and for the diagnosis of Crohn's disease. Med Clin 2004; 123: 70-76
    • (2004) Med Clin , vol.123 , pp. 70-76
    • Ruano-Ravina, A.1    Rey-Liste, T.2
  • 3
    • 33845714314 scopus 로고    scopus 로고
    • Interventional procedures: Overview of wireless capsule endoscopy
    • National Institute for Clinical Excellence. London: NICE
    • National Institute for Clinical Excellence. Interventional procedures: overview of wireless capsule endoscopy. London: NICE, 2004
    • (2004)
  • 4
    • 33845713931 scopus 로고    scopus 로고
    • Wireless capsule endoscopy for small-bowel diseases other than obscure GI bleeding
    • BlueCross BlueShield Association
    • BlueCross BlueShield Association. Wireless capsule endoscopy for small-bowel diseases other than obscure GI bleeding. Tec Assessment Program, 2003: 18 (18)
    • (2003) Tec Assessment Program , vol.18 , Issue.18
  • 5
    • 33845709164 scopus 로고    scopus 로고
    • The Cochrane Collaboration. Cochrane methods group on systematic ereviews of screening and diagnostic tests: Recommended methods [monograph on the Internet]
    • Available from
    • The Cochrane Collaboration. Cochrane methods group on systematic ereviews of screening and diagnostic tests: recommended methods [monograph on the Internet]. Available from: www.cochrane.org/sadt/ index.html
  • 6
    • 0004215333 scopus 로고    scopus 로고
    • How to review the evidence: Systematic identification and review of the scientific literature
    • National Health and Medical Research Council (NHMRC). Canberra: NHMRC
    • National Health and Medical Research Council (NHMRC). How to review the evidence: systematic identification and review of the scientific literature. Canberra: NHMRC, 2000
    • (2000)
  • 7
    • 3242809700 scopus 로고    scopus 로고
    • Development and validation of methods assessing the quality of diagnostic accuracy studies [review]
    • iii
    • Whiting P, Rutjes AWS, Dinnes J et al. Development and validation of methods assessing the quality of diagnostic accuracy studies [review]. Health Technol Assess 2004; 8 (25); iii: 1-234
    • (2004) Health Technol Assess , vol.8 , Issue.25 , pp. 1-234
    • Whiting, P.1    Rutjes, A.W.S.2    Dinnes, J.3
  • 8
    • 33845694182 scopus 로고    scopus 로고
    • Efectividad y seguridad de la cápsula endoscópica en la detección de patología del intestino delgado
    • Santiago de Compostela: Servicio Galego de Saúde, Axencia de Avaliación de Tecnoloxías Sanitarias de Galicia, AVALIA-T. Report no. CT-2004/01
    • Ruano Raviña A, Rey Liste MT. Efectividad y seguridad de la cápsula endoscópica en la detección de patología del intestino delgado. Santiago de Compostela: Servicio Galego de Saúde, Axencia de Avaliación de Tecnoloxías Sanitarias de Galicia, AVALIA-T. 2004; Report no. CT-2004/01
    • (2004)
    • Ruano Raviña, A.1    Rey Liste, M.T.2
  • 9
    • 0003532215 scopus 로고
    • The design and analysis of clinical experiments
    • New York: John Wiley & Sons Inc
    • Fleiss JL The design and analysis of clinical experiments. New York: John Wiley & Sons Inc, 1986
    • (1986)
    • Fleiss, J.L.1
  • 10
    • 1542287437 scopus 로고    scopus 로고
    • Outcome of patients with obscure gastrointestinal bleeding after capsule endoscopy: Report of 100 consecutive cases
    • Pennazio M. Santucci R, Rondonotti E et al. Outcome of patients with obscure gastrointestinal bleeding after capsule endoscopy: report of 100 consecutive cases. Gastroenterol 2004; 126: 643-653
    • (2004) Gastroenterol , vol.126 , pp. 643-653
    • Pennazio, M.1    Santucci, R.2    Rondonotti, E.3
  • 11
    • 9644269686 scopus 로고    scopus 로고
    • Clinical usefulness of the endoscopic video capsule as the initial intestinal investigation in patients with obscure digestive bleeding: Validation of a diagnostic strategy based on the patient outcome after 12 months
    • Delvaux M, Fassler I, Gay G. Clinical usefulness of the endoscopic video capsule as the initial intestinal investigation in patients with obscure digestive bleeding: validation of a diagnostic strategy based on the patient outcome after 12 months. Endoscopy 2004; 36: 1067-1073
    • (2004) Endoscopy , vol.36 , pp. 1067-1073
    • Delvaux, M.1    Fassler, I.2    Gay, G.3
  • 12
    • 0142086775 scopus 로고    scopus 로고
    • A prospective comparative study of push and wireless-capsule enteroscopy in patients with obscure digestive bleeding
    • Van Gossum A, Hittelet A, Schmit A et al. A prospective comparative study of push and wireless-capsule enteroscopy in patients with obscure digestive bleeding. Acta Gastroenterol Belg 2003; 66: 199-205
    • (2003) Acta Gastroenterol Belg , vol.66 , pp. 199-205
    • Van Gossum, A.1    Hittelet, A.2    Schmit, A.3
  • 13
    • 1842486674 scopus 로고    scopus 로고
    • A prospective comparison of capsule endoscopy and push enteroscopy in patients with GI bleeding of obscure origin
    • Adler DG, Knipschield M, Gostout C. A prospective comparison of capsule endoscopy and push enteroscopy in patients with GI bleeding of obscure origin. Gastrointest Endosc 2004; 59: 492-498
    • (2004) Gastrointest Endosc , vol.59 , pp. 492-498
    • Adler, D.G.1    Knipschield, M.2    Gostout, C.3
  • 14
    • 3242884612 scopus 로고    scopus 로고
    • Wireless capsule endoscopy in patients with obscure gastrointestinal bleeding: A comparative study with push enteroscopy
    • Mata A, Bordas JM, Feu F et al. Wireless capsule endoscopy in patients with obscure gastrointestinal bleeding: a comparative study with push enteroscopy. Aliment Pharmacol Ther 2004; 20: 189-194
    • (2004) Aliment Pharmacol Ther , vol.20 , pp. 189-194
    • Mata, A.1    Bordas, J.M.2    Feu, F.3
  • 15
    • 0345872480 scopus 로고    scopus 로고
    • Role of capsule endoscopy in patients with obscure digestive bleeding [in Spanish, abstract in English]
    • Mata A, Llach J, Bordas JM et al. Role of capsule endoscopy in patients with obscure digestive bleeding [in Spanish, abstract in English]. Gastroenterol Hepatol 2003; 26: 619-623
    • (2003) Gastroenterol Hepatol , vol.26 , pp. 619-623
    • Mata, A.1    Llach, J.2    Bordas, J.M.3
  • 16
    • 10644289411 scopus 로고    scopus 로고
    • Diagnostic yield and clinical outcomes of capsule endoscopy
    • Rastogi A, Schoen RE, Slivka A. Diagnostic yield and clinical outcomes of capsule endoscopy. Gastrointest Endosc 2004; 60: 959-964
    • (2004) Gastrointest Endosc , vol.60 , pp. 959-964
    • Rastogi, A.1    Schoen, R.E.2    Slivka, A.3
  • 17
    • 9244222167 scopus 로고    scopus 로고
    • Second capsule endoscopy for patients with severe iron deficiency anemia
    • Bar-Meir S, Eliakim R, Nadler M et al. Second capsule endoscopy for patients with severe iron deficiency anemia. Gastrointest Endosc 2004; 60: 711-713
    • (2004) Gastrointest Endosc , vol.60 , pp. 711-713
    • Bar-Meir, S.1    Eliakim, R.2    Nadler, M.3
  • 18
    • 4644229586 scopus 로고    scopus 로고
    • Wireless capsule video endoscopy compared to barium follow-through and computerised tomography in patients with suspected Crohn's disease: Final report
    • Eliakim R, Suissa A. Yassin K et al. Wireless capsule video endoscopy compared to barium follow-through and computerised tomography in patients with suspected Crohn's disease: final report. Dig Liver Dis 2004; 36: 519-522
    • (2004) Dig Liver Dis , vol.36 , pp. 519-522
    • Eliakim, R.1    Suissa, A.2    Yassin, K.3
  • 19
    • 4444379249 scopus 로고    scopus 로고
    • Capsule endoscopy in diagnosis of small bowel Crohn's disease
    • Ge ZZ, Hu YB, Xiao SD. Capsule endoscopy in diagnosis of small bowel Crohn's disease. World J Gastroenterol 2004; 10: 1349-1352
    • (2004) World J Gastroenterol , vol.10 , pp. 1349-1352
    • Ge, Z.Z.1    Hu, Y.B.2    Xiao, S.D.3
  • 20
    • 8744304961 scopus 로고    scopus 로고
    • Videocapsule endoscopy versus barium contrast studies for the diagnosis of Crohn's disease recurrence involving the small intestine
    • Buchman AI, Miller FH, Wallin A et al. Videocapsule endoscopy versus barium contrast studies for the diagnosis of Crohn's disease recurrence involving the small intestine. Am J Gastroenterol 2004: 99: 2171-2177
    • (2004) Am J Gastroenterol , vol.99 , pp. 2171-2177
    • Buchman, A.I.1    Miller, F.H.2    Wallin, A.3
  • 21
    • 14544290042 scopus 로고    scopus 로고
    • Small bowel involvement in Crohn's disease: A prospective comparison of wireless capsule endoscopy and computed tomography enteroclysis
    • Voderholzer WA, Beinhoelzl J, Rogalla P et al. Small bowel involvement in Crohn's disease: a prospective comparison of wireless capsule endoscopy and computed tomography enteroclysis. Gut 2005; 54: 369-373
    • (2005) Gut , vol.54 , pp. 369-373
    • Voderholzer, W.A.1    Beinhoelzl, J.2    Rogalla, P.3
  • 22
    • 17144433992 scopus 로고    scopus 로고
    • Utility of capsule endoscopy in pediatric gastroenterology [in Spanish, abstract in English]
    • Arguelles Arias F, Arguelles Martin F, Caunedo Alvarez A et al. Utility of capsule endoscopy in pediatric gastroenterology [in Spanish, abstract in English]. An Pediatr (Barc) 2003; 59: 586-589
    • (2003) An Pediatr (Barc) , vol.59 , pp. 586-589
    • Arguelles Arias, F.1    Arguelles Martin, F.2    Caunedo Alvarez, A.3
  • 23
    • 13744254325 scopus 로고    scopus 로고
    • Feasibility and diagnostic utility of video capsule endoscopy for the detection of small bowel polyps in patients with hereditary polyposis syndromes
    • Schulmann K, Hollerbach S, Kraus K et al. Feasibility and diagnostic utility of video capsule endoscopy for the detection of small bowel polyps in patients with hereditary polyposis syndromes. Am J Gastroenterol 2005; 100: 27-37
    • (2005) Am J Gastroenterol , vol.100 , pp. 27-37
    • Schulmann, K.1    Hollerbach, S.2    Kraus, K.3
  • 24
    • 10444276520 scopus 로고    scopus 로고
    • Comparison of capsule endoscopy and magnetic resonance imaging for the detection of polyps of the small intestine in patients with familial adenomatous polyposis or with Peutz-Jeghers' syndrome
    • Caspari R, von Falkenhausen M, Krautmacher C et al. Comparison of capsule endoscopy and magnetic resonance imaging for the detection of polyps of the small intestine in patients with familial adenomatous polyposis or with Peutz-Jeghers' syndrome. Endoscopy 2004; 36: 1054-1059
    • (2004) Endoscopy , vol.36 , pp. 1054-1059
    • Caspari, R.1    von Falkenhausen, M.2    Krautmacher, C.3
  • 25
    • 10444239285 scopus 로고    scopus 로고
    • Wireless capsule endoscopy for evaluation of phenotypic expression of small-bowel polyps in patients with Peutz-Jeghers syndrome and in symptomatic first-degree relatives
    • Soares J, Lopes I, Boas GV, Pinho C. Wireless capsule endoscopy for evaluation of phenotypic expression of small-bowel polyps in patients with Peutz-Jeghers syndrome and in symptomatic first-degree relatives. Endoscopy 2004; 36: 1060-1066
    • (2004) Endoscopy , vol.36 , pp. 1060-1066
    • Soares, J.1    Lopes, I.2    Boas, G.V.3    Pinho, C.4
  • 27
    • 0041386375 scopus 로고    scopus 로고
    • Capsule endoscopy for the evaluation of patients with chronic abdominal pain
    • Bardan E, Nadler M. Chowers Yet al. Capsule endoscopy for the evaluation of patients with chronic abdominal pain. Endoscopy 2003, 35: 688-689
    • (2003) Endoscopy , vol.35 , pp. 688-689
    • Bardan, E.1    Nadler, M.2    Chowers, Y.3
  • 28
    • 10644249811 scopus 로고    scopus 로고
    • Impact of small bowel exploration using video-capsule endoscopy in the management of acute gastrointestinal graft-versus-host disease
    • Yakoub-Agha I, Maunoury V, Wacrenier A et al. Impact of small bowel exploration using video-capsule endoscopy in the management of acute gastrointestinal graft-versus-host disease. Transplantation 2004; 78:1697-1701
    • (2004) Transplantation , vol.78 , pp. 1697-1701
    • Yakoub-Agha, I.1    Maunoury, V.2    Wacrenier, A.3
  • 29
    • 9244261580 scopus 로고    scopus 로고
    • Frequency and clinical outcome of capsule retention during capsule endoscopy for GI bleeding of obscure origin
    • Sears DM, Avots-Avotins A, Culp K, Gavin MW. Frequency and clinical outcome of capsule retention during capsule endoscopy for GI bleeding of obscure origin. Gastrointest Endosc 2004; 60: 822-827
    • (2004) Gastrointest Endosc , vol.60 , pp. 822-827
    • Sears, D.M.1    Avots-Avotins, A.2    Culp, K.3    Gavin, M.W.4
  • 30
    • 33845718468 scopus 로고    scopus 로고
    • Capacidad diagnóstica y seguridad de la cápsula endoscópica en patología del intestino delgado
    • Agència d́Avaluació de Tecnologia i Recerca Mèdiques. Ministerio de Sanidad y Consumo
    • Oliva G, Almazán C, de Solà-Morales O. Capacidad diagnóstica y seguridad de la cápsula endoscópica en patología del intestino delgado. Agència d́Avaluació de Tecnologia i Recerca Mèdiques. Ministerio de Sanidad y Consumo, 2003
    • (2003)
    • Oliva, G.1    Almazán, C.2    de Solà-Morales, O.3
  • 31
    • 4243785282 scopus 로고    scopus 로고
    • Assessing diagnostic technologies
    • Boston: Technology Assessment Program: Health Services Research & Development Service (HSR&D) Report no. 1
    • Flynn K. Assessing diagnostic technologies. Boston: Technology Assessment Program: Health Services Research & Development Service (HSR&D) 1996: Report no. 1
    • (1996)
    • Flynn, K.1
  • 32
    • 4243430012 scopus 로고    scopus 로고
    • Levels of evidence
    • London: NHS R&D Centre for Evidence-Based Evidence
    • Phillips B, Ball C, Sackett D et al. Levels of evidence. London: NHS R&D Centre for Evidence-Based Evidence, 2002
    • (2002)
    • Phillips, B.1    Ball, C.2    Sackett, D.3
  • 33
    • 0036673446 scopus 로고    scopus 로고
    • Role of capsule endoscopy in the management of patients with obscure gastrointestinal bleeding
    • Caunedo Alvarez A, Rodríguez-Téllez N, García Montes JM et al. Role of capsule endoscopy in the management of patients with obscure gastrointestinal bleeding. Rev Esp Enferm Dig 2002; 94: 482-487
    • (2002) Rev Esp Enferm Dig , vol.94 , pp. 482-487
    • Caunedo Alvarez, A.1    Rodríguez-Téllez, N.2    García Montes, J.M.3
  • 34
    • 20344373651 scopus 로고    scopus 로고
    • A prospective two-center study comparing wireless capsule endoscopy with intraoperative enteroscopy in patients with obscure bleeding
    • Hartmann D, Schmidt H, Schilling D et al. A prospective two-center study comparing wireless capsule endoscopy with intraoperative enteroscopy in patients with obscure bleeding. Gastrointest Endosc 2005; 61: 826-832
    • (2005) Gastrointest Endosc , vol.61 , pp. 826-832
    • Hartmann, D.1    Schmidt, H.2    Schilling, D.3
  • 35
    • 33845707814 scopus 로고    scopus 로고
    • Metaanálisis
    • In: Doménech JM (ed). Barcelona: Editorial-Gráficas Signo
    • Rodríguez MD. Metaanálisis. In: Doménech JM (ed). Diseño de estudios sanitarios. Barcelona: Editorial-Gráficas Signo, 2000
    • (2000) Diseño De Estudios Sanitarios
    • Rodríguez, M.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.