메뉴 건너뛰기




Volumn 26, Issue 10, 2003, Pages 619-623

Role of capsule endoscopy in patients with obscure digestive bleeding;Papel de la cápsula endoscópica en los pacientes con hemorragia digestiva de origen indeterminado

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; AGED; ANGIODYSPLASIA; ARTICLE; CLINICAL ARTICLE; COLONOSCOPY; CROHN DISEASE; DIAGNOSTIC ACCURACY; FEMALE; FIBERSCOPE ENDOSCOPY; GASTROINTESTINAL ENDOSCOPY; GASTROINTESTINAL HEMORRHAGE; GASTROSCOPY; HUMAN; JEJUNUM ULCER; MALE; OCCULT BLOOD; TISSUE DISTRIBUTION;

EID: 0345872480     PISSN: 02105705     EISSN: None     Source Type: Journal    
DOI: 10.1157/13055131     Document Type: Article
Times cited : (16)

References (18)
  • 1
    • 0029016135 scopus 로고
    • Incidence of and mortality from acute upper gastrointestinal haemorrhage in the United Kingdom
    • Rockall T, Logan R, Devlin H, Northfield T. Incidence of and mortality from acute upper gastrointestinal haemorrhage in the United Kingdom. BMJ 1995;311:222-4.
    • (1995) BMJ , vol.311 , pp. 222-224
    • Rockall, T.1    Logan, R.2    Devlin, H.3    Northfield, T.4
  • 7
    • 0034546556 scopus 로고    scopus 로고
    • A randomised trial comparing wireless capsule endoscopy with push enteroscopy for the detection of small bowel lesions
    • Appleyard M, Fireman Z, Glukhovsky A, Jacob H, Shreiver R, Kadirkamanathan S, et al. A randomised trial comparing wireless capsule endoscopy with push enteroscopy for the detection of small bowel lesions. Gastroenterology 2000;119:1431-8.
    • (2000) Gastroenterology , vol.119 , pp. 1431-1438
    • Appleyard, M.1    Fireman, Z.2    Glukhovsky, A.3    Jacob, H.4    Shreiver, R.5    Kadirkamanathan, S.6
  • 8
    • 0035905884 scopus 로고    scopus 로고
    • Wireless-capsule diagnostic endoscopy for recurrent small bowel bleeding
    • Appleyard M, Glukhovsky A, Swain P. Wireless-capsule diagnostic endoscopy for recurrent small bowel bleeding. N Engl J Med 2001;344:232-3.
    • (2001) N Engl J Med , vol.344 , pp. 232-233
    • Appleyard, M.1    Glukhovsky, A.2    Swain, P.3
  • 9
    • 0036740197 scopus 로고    scopus 로고
    • Capsule endoscopy in the evaluation of patients with suspected small intestinal bleeding: Results of a pilot study
    • Lewis B, Swain P. Capsule endoscopy in the evaluation of patients with suspected small intestinal bleeding: results of a pilot study. Gastrointest Endosc 2002;56:349-53.
    • (2002) Gastrointest Endosc , vol.56 , pp. 349-353
    • Lewis, B.1    Swain, P.2
  • 10
    • 0036350477 scopus 로고    scopus 로고
    • The first prospective controlled trial comparing wireless capsule endoscopy with push enteroscopy in chronic gastrointestinal bleeding
    • Ell C, Remke S, May A, Helou L, Henrich R, Mayer G. The first prospective controlled trial comparing wireless capsule endoscopy with push enteroscopy in chronic gastrointestinal bleeding. Endoscopy 2002;34:685-9.
    • (2002) Endoscopy , vol.34 , pp. 685-689
    • Ell, C.1    Remke, S.2    May, A.3    Helou, L.4    Henrich, R.5    Mayer, G.6
  • 11
    • 0036789127 scopus 로고    scopus 로고
    • A prospective trial comparing small bowel radiographs and video capsule endoscopy for suspected small bowell disease
    • Costamagna G, Shah A, Riccioni ME, Foschia F, Mutignani M, Perri V, et al. A prospective trial comparing small bowel radiographs and video capsule endoscopy for suspected small bowell disease. Gastroenterology 2002;123:999-1005.
    • (2002) Gastroenterology , vol.123 , pp. 999-1005
    • Costamagna, G.1    Shah, A.2    Riccioni, M.E.3    Foschia, F.4    Mutignani, M.5    Perri, V.6
  • 12
    • 0036841087 scopus 로고    scopus 로고
    • Initial experience of wireless-capsule endoscopy for evaluating occult gastrointestinal bleeding and suspected small bowel pathology
    • Scapa E, Jacob H, Lewkowicz S, Migdal M, Gat D, Gluckhovski A, et al. Initial experience of wireless-capsule endoscopy for evaluating occult gastrointestinal bleeding and suspected small bowel pathology. Am J Gastroenterol 2002;97:2776-9.
    • (2002) Am J Gastroenterol , vol.97 , pp. 2776-2779
    • Scapa, E.1    Jacob, H.2    Lewkowicz, S.3    Migdal, M.4    Gat, D.5    Gluckhovski, A.6
  • 13
    • 0037372740 scopus 로고    scopus 로고
    • Diagnosing small bowel Crohn's disease with wireless capsule endoscopy
    • Fireman Z, Mahajna E, Broide E, Shapiro M, Fich L, Sternberg A, et al. Diagnosing small bowel Crohn's disease with wireless capsule endoscopy. Gut 2003;52:390-2.
    • (2003) Gut , vol.52 , pp. 390-392
    • Fireman, Z.1    Mahajna, E.2    Broide, E.3    Shapiro, M.4    Fich, L.5    Sternberg, A.6
  • 14
    • 0242668401 scopus 로고    scopus 로고
    • Wireless capsule video endoscopy is a superior diagnostic tool in comparison to barium follow-through and computarized tomography in patients with suspected Crohn's disease
    • Eliakim R, Fischer D, Suissa A, Yassin K, Katz D, Guttman N, et al. Wireless capsule video endoscopy is a superior diagnostic tool in comparison to barium follow-through and computarized tomography in patients with suspected Crohn's disease. Eur J Gastroenterol Hepatol 2003;15:363-7.
    • (2003) Eur J Gastroenterol Hepatol , vol.15 , pp. 363-367
    • Eliakim, R.1    Fischer, D.2    Suissa, A.3    Yassin, K.4    Katz, D.5    Guttman, N.6
  • 15
    • 0038513895 scopus 로고    scopus 로고
    • Capsule endoscopy versus push enteroscopy in patients with occult gastrointestinal bleeding
    • Hartmann D, Schilling D, Bolz G, Hahne M, Jakobs R, Siegel E, et al. Capsule endoscopy versus push enteroscopy in patients with occult gastrointestinal bleeding. Z Gastroenterol 2003;41:377-82.
    • (2003) Z Gastroenterol , vol.41 , pp. 377-382
    • Hartmann, D.1    Schilling, D.2    Bolz, G.3    Hahne, M.4    Jakobs, R.5    Siegel, E.6
  • 16
    • 0038637384 scopus 로고    scopus 로고
    • Wireless capsule endoscopy: A comparison with push enteroscopy in patients with gastroscopy and colonoscopy negative gastrointestinal bleeding
    • Mylonaki M, Fritscher-Ravens A, Swain A. Wireless capsule endoscopy: a comparison with push enteroscopy in patients with gastroscopy and colonoscopy negative gastrointestinal bleeding. Gut 2003;52:1122-6.
    • (2003) Gut , vol.52 , pp. 1122-1126
    • Mylonaki, M.1    Fritscher-Ravens, A.2    Swain, A.3
  • 17
    • 0037381611 scopus 로고    scopus 로고
    • The importance of indication in the diagnostic value of push enteroscopy
    • Lin S, Branch MS, Shetzline M. The importance of indication in the diagnostic value of push enteroscopy. Endoscopy 2003;35:315-21.
    • (2003) Endoscopy , vol.35 , pp. 315-321
    • Lin, S.1    Branch, M.S.2    Shetzline, M.3
  • 18
    • 0037478596 scopus 로고    scopus 로고
    • Diagnostic value of endoscopic capsule in patients with obscure digestive bleeding: Blinded comparison with video push-enteroscopy
    • Saurin JC, Delvaux M, Gaudin JL, Fassler I, Villarejo J, Vahedi K, et al. Diagnostic value of endoscopic capsule in patients with obscure digestive bleeding: blinded comparison with video push-enteroscopy. Endoscopy 2003;35:576-84.
    • (2003) Endoscopy , vol.35 , pp. 576-584
    • Saurin, J.C.1    Delvaux, M.2    Gaudin, J.L.3    Fassler, I.4    Villarejo, J.5    Vahedi, K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.